| Literature DB >> 16356244 |
Devanand Anantham1, Raghuram Jagadesan, Philip Eng Cher Tiew.
Abstract
Independent lung ventilation (ILV) can be classified into anatomical and physiological lung separation. It requires either endobronchial blockade or double-lumen endotracheal tube intubation. Endobronchial blockade or selective double-lumen tube ventilation may necessitate temporary one lung ventilation. Anatomical lung separation isolates a diseased lung from contaminating the non-diseased lung. Physiological lung separation ventilates each lung as an independent unit. There are some clear indications for ILV as a primary intervention and as a rescue ventilator strategy in both anatomical and physiological lung separation. Potential pitfalls are related to establishing and maintaining lung isolation. Nevertheless, ILV can be used in the intensive care setting safely with a good understanding of its limitations and potential complications.Entities:
Mesh:
Year: 2005 PMID: 16356244 PMCID: PMC1414047 DOI: 10.1186/cc3827
Source DB: PubMed Journal: Crit Care ISSN: 1364-8535 Impact factor: 9.097
Indications for independent lung ventilation in critical care
| Independent lung ventilation | Indication |
| Anatomical lung separation | Massive hemoptysis |
| Whole lung lavage for pulmonary alveolar proteinosis | |
| Copious secretions (e.g. bronchiectasis, lung abscess) | |
| Physiological lung separation | Unilateral parenchymal injury |
| Aspiration | |
| Pulmonary contusion | |
| Pneumonia | |
| Unilateral pulmonary edema | |
| Single lung transplant (post operative complications) | |
| Bronchopleural fistula | |
| Unilateral bronchospasm | |
| Severe bilateral lung disease failing conventional ventilationa |
aControversial indication.
Comparative sizing of single-lumen, Univent and double-lumen tubes [12]
| Single-lumen endotracheal tubes (internal diameter in mm) | Univent tubes (internal diameter in mm) | Double-lumen tube (F) |
| 12.5 | 9.0 | 41 |
| 12.0 | 8.5 | 39 |
| 11.0 | 8.0 | 37 |
| 9.5 | 7.5 | 35 |
| 9.0 | 7.0 | 33 |
| 8.0 | 6.0 | 28 |
Sizing polyvinyl chloride double-lumen tubes [63]
| Tube size (F) | Circumference (mm) | Lumen diameter (mm) | Indication |
| 35 | 38.0 | 5.0 | Pediatrics |
| 37 | 40.0 | 5.5 | Small adults |
| 39 | 44.0 | 6.0 | Medium adults, usual female size |
| 41 | 45.0 | 6.5 | Large adults, usual male size |