Initial in vivo evaluation of the DexAide right ventricular assist device.

Yoshio Ootaki1, Keiji Kamohara, Masatoshi Akiyama, Firas Zahr, Michael W Kopcak, Raymond Dessoffy, Alex Massiello, David Horvath, Ji-Feng Chen, Stephen Benefit, Leonard A R Golding, Kiyotaka Fukamachi.   

Abstract

Despite the increasing use of left ventricular assist devices for patients with end-stage congestive heart failure, no implantable, centrifugal right ventricular assist devices (RVADs) are available for those patients with significant right ventricular failure. The DexAide RVAD was developed to provide an implantable RVAD option to surgeons. The aim of this study was to evaluate pump performance in an acute in vivo model. The DexAide RVAD, developed as a modified CorAide left ventricular assist device, was implanted between the right ventricle and the pulmonary artery in four healthy calves. Pump speed was varied from 1800 rpm to 3600 rpm. RVAD performance was analyzed acutely at baseline and under conditions of low circulating volume, high contractility, high pulmonary arterial pressure, vasodilation, and low contractility. Pump flow was well maintained even under conditions of high pulmonary arterial pressure and vasodilation, with the exception of low circulating volume. Under all conditions, pulmonary arterial pressures were not affected by changing pump speed. The DexAide RVAD demonstrated acceptable hemodynamic characteristics for use as an implantable RVAD in the initial acute studies. Further studies are ongoing to examine the biocompatibility of the pump under chronic conditions.

Entities:  

Mesh:

Year:  2005        PMID: 16340360      PMCID: PMC1363716          DOI: 10.1097/01.mat.0000187399.46756.fc

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  21 in total

1.  The CorAid blood pump.

Authors:  D J Horvath; L A Golding; A Massiello; A L Medvedev; R L Gerhart; Y Ochiai; A Krogulecki; K Fukamachi
Journal:  Ann Thorac Surg       Date:  2001-03       Impact factor: 4.330

2.  In vivo hemodynamic performance of the Cleveland Clinic CorAide blood pump in calves.

Authors:  Y Ochiai; L A Golding; A L Massiello; A L Medvedev; R L Gerhart; J F Chen; M Takagaki; K Fukamachi
Journal:  Ann Thorac Surg       Date:  2001-09       Impact factor: 4.330

3.  Development of a small implantable right ventricular assist device.

Authors:  Kiyotaka Fukamachi; David J Horvath; Alex L Massiello; Yoshio Ootaki; Keiji Kamohara; Masatoshi Akiyama; Firas Zahr; Michael W Kopcak; Raymond Dessoffy; Ji-Feng Chen; Stephen Benefit; Leonard A R Golding
Journal:  ASAIO J       Date:  2005 Nov-Dec       Impact factor: 2.872

4.  Preoperative risk factors for right ventricular failure after implantable left ventricular assist device insertion.

Authors:  K Fukamachi; P M McCarthy; N G Smedira; R L Vargo; R C Starling; J B Young
Journal:  Ann Thorac Surg       Date:  1999-12       Impact factor: 4.330

5.  A versatile intracorporeal ventricular assist device based on the thoratec VAD system.

Authors:  S H Reichenbach; D J Farrar; J D Hill
Journal:  Ann Thorac Surg       Date:  2001-03       Impact factor: 4.330

6.  Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system.

Authors:  O H Frazier; Timothy J Myers; Igor D Gregoric; Tehreen Khan; Reynolds Delgado; Mihai Croitoru; Kathy Miller; Robert Jarvik; Stephen Westaby
Journal:  Circulation       Date:  2002-06-18       Impact factor: 29.690

7.  Chronic evaluation of the Cleveland Clinic CorAide left ventricular assist system in calves.

Authors:  Kiyotaka Fukamachi; Yoshie Ochiai; Kazuyoshi Doi; Alex L Massiello; Alexander L Medvedev; David J Horvath; Renee L Gerhart; Ji-Feng Chen; Alexandra Y Krogulecki; Masami Takagaki; Michael W Howard; Michael W Kopcak; Leonard A R Golding
Journal:  Artif Organs       Date:  2002-06       Impact factor: 3.094

8.  Cleveland clinic CorAide blood pump circulatory support without anticoagulation.

Authors:  Yoshie Ochiai; Leonard A R Golding; Alex L Massiello; Alexander L Medvedev; David J Horvath; Renee L Gerhart; Ji-Feng Chen; Alexandra Y Krogulecki; Masami Takagaki; Kazuyoshi Doi; Michael W Howard; Kiyotaka Fukamachi
Journal:  ASAIO J       Date:  2002 May-Jun       Impact factor: 2.872

9.  Predictors of severe right ventricular failure after implantable left ventricular assist device insertion: analysis of 245 patients.

Authors:  Yoshie Ochiai; Patrick M McCarthy; Nicholas G Smedira; Michael K Banbury; Jose L Navia; Jingyuan Feng; Amy P Hsu; Michael L Yeager; Tiffany Buda; Katherine J Hoercher; Michael W Howard; Masami Takagaki; Kazuyoshi Doi; Kiyotaka Fukamachi
Journal:  Circulation       Date:  2002-09-24       Impact factor: 29.690

Review 10.  Continuous flow pumps and total artificial hearts: management issues.

Authors:  Timothy J Myers; Kimberly Robertson; Toni Pool; Nyma Shah; Igor Gregoric; O H Frazier
Journal:  Ann Thorac Surg       Date:  2003-06       Impact factor: 4.330

View more
  1 in total

1.  Introduction of fixed-flow mode in the DexAide right ventricular assist device.

Authors:  Diyar Saeed; Alex L Massiello; Shanaz Shalli; Hideyuki Fumoto; Tetsuya Horai; Tomohiro Anzai; Leonard A R Golding; Kiyotaka Fukamachi
Journal:  J Heart Lung Transplant       Date:  2010-01       Impact factor: 10.247

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.