Literature DB >> 12058998

Cleveland clinic CorAide blood pump circulatory support without anticoagulation.

Yoshie Ochiai1, Leonard A R Golding, Alex L Massiello, Alexander L Medvedev, David J Horvath, Renee L Gerhart, Ji-Feng Chen, Alexandra Y Krogulecki, Masami Takagaki, Kazuyoshi Doi, Michael W Howard, Kiyotaka Fukamachi.   

Abstract

The Cleveland Clinic CorAide left ventricular assist system consists of a permanently implantable centrifugal pump in which the rotating assembly is completely suspended and noncontacting. A series of chronic animal in vivo studies were conducted to evaluate the biologic effects of CorAide circulatory support without the use of anticoagulation therapy. The CorAide pump was implanted in six calves (five calves for 21 to 32 days and one calf for 95 days). The first five calves received intravenous heparin during the early postoperative periods (2-7 days). Heparin administration was then discontinued and no other anticoagulant drugs were used for the duration of the experiments. The last calf did not receive any anticoagulant except for a bolus dose of heparin (200 U/kg) during surgery. Hemodynamics were stable in all six calves, with a mean pump flow of 5.6+/-1.2 L/min and mean arterial pressure of 100+/-4 mm Hg. The blood pump surfaces were clean of thrombus in all six calves. Significant findings at autopsy were limited to one case of renal infarction. There was no incidence of mechanical failure, bleeding, or device infection. The CorAide pump can be safely run with minimal or no anticoagulant therapy.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12058998     DOI: 10.1097/00002480-200205000-00009

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  4 in total

1.  The future of adult cardiac assist devices: novel systems and mechanical circulatory support strategies.

Authors:  Carlo R Bartoli; Robert D Dowling
Journal:  Cardiol Clin       Date:  2011-11       Impact factor: 2.213

2.  Initial in vivo evaluation of the DexAide right ventricular assist device.

Authors:  Yoshio Ootaki; Keiji Kamohara; Masatoshi Akiyama; Firas Zahr; Michael W Kopcak; Raymond Dessoffy; Alex Massiello; David Horvath; Ji-Feng Chen; Stephen Benefit; Leonard A R Golding; Kiyotaka Fukamachi
Journal:  ASAIO J       Date:  2005 Nov-Dec       Impact factor: 2.872

3.  Development of a small implantable right ventricular assist device.

Authors:  Kiyotaka Fukamachi; David J Horvath; Alex L Massiello; Yoshio Ootaki; Keiji Kamohara; Masatoshi Akiyama; Firas Zahr; Michael W Kopcak; Raymond Dessoffy; Ji-Feng Chen; Stephen Benefit; Leonard A R Golding
Journal:  ASAIO J       Date:  2005 Nov-Dec       Impact factor: 2.872

4.  Reduced pulsatility induces periarteritis in kidney: role of the local renin-angiotensin system.

Authors:  Chiyo Ootaki; Michifumi Yamashita; Yoshio Ootaki; Keiji Kamohara; Stephan Weber; Ryan S Klatte; William A Smith; Alex L Massiello; Steven N Emancipator; Leonard A R Golding; Kiyotaka Fukamachi
Journal:  J Thorac Cardiovasc Surg       Date:  2008-05-19       Impact factor: 5.209

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.