Literature DB >> 16333164

Monte Carlo study of Siemens PRIMUS photoneutron production.

J Pena1, L Franco, F Gómez, A Iglesias, J Pardo, M Pombar.   

Abstract

Neutron production in radiotherapy facilities has been studied from the early days of modern linacs. Detailed studies are now possible using photoneutron capabilities of general-purpose Monte Carlo codes at energies of interest in medical physics. The present work studies the effects of modelling different accelerator head and room geometries on the neutron fluence and spectra predicted via Monte Carlo. The results from the simulation of a 15 MV Siemens PRIMUS linac show an 80% increase in the fluence scored at the isocentre when, besides modelling the components necessary for electron/photon simulations, other massive accelerator head components are included. Neutron fluence dependence on inner treatment room volume is analysed showing that thermal neutrons have a 'gaseous' behaviour and then a 1/V dependence. Neutron fluence maps for three energy ranges, fast (E > 0.1 MeV), epithermal (1 eV < E < 0.1 MeV) and thermal (E < 1 eV), are also presented and the influence of the head components on them is discussed.

Mesh:

Year:  2005        PMID: 16333164     DOI: 10.1088/0031-9155/50/24/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

Review 1.  A review on photoneutrons characteristics in radiation therapy with high-energy photon beams.

Authors:  Alireza Naseri; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2010-09-22

2.  Secondary neutron spectra from modern Varian, Siemens, and Elekta linacs with multileaf collimators.

Authors:  Rebecca M Howell; Stephen F Kry; Eric Burgett; Nolan E Hertel; David S Followill
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

3.  Secondary radiation dose during high-energy total body irradiation.

Authors:  M Janiszewska; K Polaczek-Grelik; M Raczkowski; B Szafron; A Konefał; W Zipper
Journal:  Strahlenther Onkol       Date:  2014-03-06       Impact factor: 3.621

4.  Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation.

Authors:  Bryan Bednarz; X George Xu
Journal:  Phys Med Biol       Date:  2009-01-14       Impact factor: 3.609

Review 5.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609

6.  Cephalometric assessment of the axial inclination of upper and lower incisors in relation to the third-order angle.

Authors:  Michael Knösel; Rengin Attin; Dietmar Kubein-Meesenburg; Reza Sadat-Khonsari
Journal:  J Orofac Orthop       Date:  2007-05       Impact factor: 1.938

7.  Monte Carlo calculation of photo-neutron dose produced by circular cones at 18 MV photon beams.

Authors:  Elham Hosseinzadeh; Nooshin Banaee; Hassan Ali Nedaie
Journal:  Rep Pract Oncol Radiother       Date:  2018-01-09

Review 8.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

9.  Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations.

Authors:  Hassan Ali Nedaie; Hoda Darestani; Nooshin Banaee; Negin Shagholi; Kheirollah Mohammadi; Arjang Shahvar; Esmaeel Bayat
Journal:  J Med Phys       Date:  2014-01

10.  Flattening filter-free accelerators: a report from the AAPM Therapy Emerging Technology Assessment Work Group.

Authors:  Ying Xiao; Stephen F Kry; Richard Popple; Ellen Yorke; Niko Papanikolaou; Sotirios Stathakis; Ping Xia; Saiful Huq; John Bayouth; James Galvin; Fang-Fang Yin
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102