Literature DB >> 16331593

Multislice, dual-imaging sequence for increasing the dynamic range of the contrast-enhanced blood signal and CNR of myocardial enhancement at 3T.

Daniel Kim1, Leon Axel.   

Abstract

PURPOSE: To develop a multislice, first-pass perfusion imaging sequence for increasing the effective dynamic range of the contrast-enhanced blood signal and the contrast-to-noise ratio (CNR) of myocardial wall enhancement.
MATERIALS AND METHODS: A hybrid echo-planar imaging (EPI) pulse sequence was modified to acquire data for both the arterial input function (AIF) and the myocardium, using two different saturation-recovery time delays (TDs) and spatial resolutions, after a single saturation pulse. Five healthy subjects were scanned at 3T in three short-axis levels of the heart per heartbeat during passage of a high-dose bolus of contrast agent. The T(1)-weighted signal-time curve of the blood was converted to AIF using empirical conversion tables derived from phantom experiments.
RESULTS: In all subjects the calculated AIF was consistently less distorted and higher for the short-TD protocol than for the long-TD protocol (peak concentration: 5.0 +/- 1.0 mM vs. 3.0 +/- 0.6 mM; P < 0.01). A combination of EPI, long TD, high-dose bolus of contrast agent, and 3T imaging yielded relatively strong peak enhancement in the myocardium (CNR = 11.9 +/- 3.3).
CONCLUSION: Our dual-imaging approach at 3T seems promising for acquiring both a relatively accurate AIF and a high CNR of myocardial wall enhancement in multiple slices per heartbeat.

Mesh:

Substances:

Year:  2006        PMID: 16331593     DOI: 10.1002/jmri.20471

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  31 in total

1.  T2* measurement during first-pass contrast-enhanced cardiac perfusion imaging.

Authors:  Peter Kellman; Anthony H Aletras; Li-Yueh Hsu; Elliot R McVeigh; Andrew E Arai
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

2.  High-resolution myocardial perfusion imaging at 3 T: comparison to 1.5 T in healthy volunteers.

Authors:  K Strach; C Meyer; D Thomas; C P Naehle; C Schmitz; H Litt; A Bernstein; B Cheng; H Schild; T Sommer
Journal:  Eur Radiol       Date:  2007-02-16       Impact factor: 5.315

3.  High-resolution myocardial stress perfusion at 3 T in patients with suspected coronary artery disease.

Authors:  Carsten Meyer; Katharina Strach; Daniel Thomas; Harold Litt; Claas P Nähle; Klaus Tiemann; Ulrich Schwenger; Hans H Schild; Torsten Sommer
Journal:  Eur Radiol       Date:  2007-09-13       Impact factor: 5.315

4.  Accelerated dual-contrast first-pass perfusion MRI of the mouse heart: development and application to diet-induced obese mice.

Authors:  Nivedita K Naresh; Xiao Chen; Rene J Roy; Patrick F Antkowiak; Brian H Annex; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2014-04-23       Impact factor: 4.668

5.  Free-breathing cardiac MR stress perfusion with real-time slice tracking.

Authors:  Tamer A Basha; Sébastien Roujol; Kraig V Kissinger; Beth Goddu; Sophie Berg; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

6.  Constrained estimation of the arterial input function for myocardial perfusion cardiovascular magnetic resonance.

Authors:  Jacob U Fluckiger; Matthias C Schabel; Edward V R DiBella
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

7.  Clinical applications for cardiovascular magnetic resonance imaging at 3 tesla.

Authors:  Allison G Hays; Michael Schär; Sebastian Kelle
Journal:  Curr Cardiol Rev       Date:  2009-08

Review 8.  Quantification of myocardial perfusion by cardiovascular magnetic resonance.

Authors:  Michael Jerosch-Herold
Journal:  J Cardiovasc Magn Reson       Date:  2010-10-08       Impact factor: 5.364

9.  Quantification of myocardial perfusion using CMR with a radial data acquisition: comparison with a dual-bolus method.

Authors:  Tae Ho Kim; Nathan A Pack; Liyong Chen; Edward V R DiBella
Journal:  J Cardiovasc Magn Reson       Date:  2010-07-23       Impact factor: 5.364

10.  Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study.

Authors:  Taehoon Shin; Houchun H Hu; Gerald M Pohost; Krishna S Nayak
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-11       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.