Aneurysmal rupture during coiling: low incidence and good outcomes at a single large volume center.

Jonathan L Brisman1, Yasunari Niimi, Joon K Song, Alejandro Berenstein.   

Abstract

OBJECTIVE: To study the incidence and clinical outcomes of intraoperative aneurysm rupture (IOR) during endovascular coil embolization at a single large volume center and to review the literature on this subject to determine whether IOR rupture rate and mortality correlate with volume of aneurysms treated at a given center and years since the institution of Guglielmi detachable coils as a treatment modality.
METHODS: We reviewed the aneurysm database at the Center for Endovascular Surgery since its inception (1997-2003) and reviewed 600 consecutively treated intracranial aneurysms in which coiling was attempted. All patients who sustained an IOR were studied. Procedural and follow-up angiograms as well as clinical outcomes were retrospectively reviewed. A literature review was conducted.
RESULTS: Six patients (1.0%) experienced IOR (1.4% in acutely ruptured lesions, 0% in unruptured). All six had presented with diffuse subarachnoid hemorrhage (Fisher Grade 3) and in good clinical grade (Hunt & Hess Grades 1-3). One patient was rendered permanently disabled secondary to delay in controlling the IOR. All others were neurologically unchanged. A review of the literature revealed a trend in correlation between volume of aneurysms treated and IOR rate; no statistically significant correlation was found between volume of aneurysms treated or years since the introduction of GDC technology and IOR rates or mortality.
CONCLUSION: IOR remains a serious risk of endosaccular coiling of intracranial aneurysms, with aneurysms presenting with subarachnoid hemorrhage at greater risk for this complication. This risk can be minimized with very low associated morbidity and mortality (incidence 1%, 17% morbidity, 0% mortality at our institution).

Entities:  

Mesh:

Year:  2005        PMID: 16331157     DOI: 10.1227/01.neu.0000185631.20246.1a

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  21 in total

Review 1.  Endovascular treatment of distal anterior cerebral artery aneurysms: single-center experience and a systematic review.

Authors:  C L Sturiale; W Brinjikji; M H Murad; H J Cloft; D F Kallmes; G Lanzino
Journal:  AJNR Am J Neuroradiol       Date:  2013-07-18       Impact factor: 3.825

2.  Symptomatic periprocedural intracranial hemorrhage unrelated to coil embolization in 1287 patients with intracranial aneurysms.

Authors:  Haowen Xu; Li Wang; Sheng Guan; Dongdong Li; Tao Quan
Journal:  Neuroradiology       Date:  2018-06-29       Impact factor: 2.804

3.  Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases.

Authors:  Tobias Struffert; Gregor Richter; Tobias Engelhorn; Marc Doelken; Philipp Goelitz; Willi A Kalender; Oliver Ganslandt; Arnd Doerfler
Journal:  Eur Radiol       Date:  2008-09-24       Impact factor: 5.315

4.  Short- and intermediate-term angiographic and clinical outcomes of patients with various grades of coil protrusions following embolization of intracranial aneurysms.

Authors:  M Abdihalim; S H Kim; A Maud; M F K Suri; N Tariq; A I Qureshi
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-01       Impact factor: 3.825

5.  Incidence and neurological outcomes of aneurysm rupture during interventional neuroradiology procedures in a hybrid operating suite.

Authors:  Kentaro Yamakawa; Shuya Kiyama; Yuichi Murayama; Shoichi Uezono
Journal:  J Anesth       Date:  2012-02-24       Impact factor: 2.078

6.  Fatal avulsion of choroidal or perforating arteries by guidewires. Case reports, ex vivo experiments, potential mechanisms and prevention.

Authors:  Tim E Darsaut; Vincent Costalat; Igor Salazkin; Sara Jamali; France Berthelet; Guylaine Gevry; Daniel Roy; Jean Raymond
Journal:  Interv Neuroradiol       Date:  2014-06-17       Impact factor: 1.610

7.  Force characterization of intracranial endovascular embolization: coil type, microcatheter placement, and insertion rate.

Authors:  Jonathan B Lamano; Grace G Bushnell; Hongyu Chen; Avanti Badrinathan; Najib E El Tecle; Bernard R Bendok; Matthew R Glucksberg
Journal:  Neurosurgery       Date:  2014-12       Impact factor: 4.654

Review 8.  Complications of endovascular treatment for intracranial aneurysms: Management and prevention.

Authors:  Yon Kwon Ihn; Shang Hun Shin; Seung Kug Baik; In Sup Choi
Journal:  Interv Neuroradiol       Date:  2018-02-21       Impact factor: 1.610

9.  Safety of stent-assisted coiling for the treatment of wide-necked ruptured aneurysm: A systematic literature review and meta-analysis of prevalence.

Authors:  Shadi Bsat; Ayman Bsat; Hani Tamim; Hani Chanbour; Safwan Omar Alomari; Mohamad Nabih El Houshiemy; Charbel Moussalem; Ibrahim Omeis
Journal:  Interv Neuroradiol       Date:  2020-08-02       Impact factor: 1.610

10.  AngioCT in the management of neurointerventional patients: a prospective, consecutive series with associated dosimetry and resolution data.

Authors:  Philip M White; John N Gilmour; Nicholas W Weir; Brian Innes; Robin J Sellar
Journal:  Neuroradiology       Date:  2007-12-21       Impact factor: 2.804