PURPOSE: To optimize R2*(1/T2*) measurements for cardiac iron detection in sickle cell and thalassemia patients. MATERIALS AND METHODS: We studied 31 patients with transfusion-dependent sickle cell disease and 48 patients with thalassemia major; myocardial R2* was assessed in a single midpapillary slice using a gated gradient-echo pulse sequence. Pixel-wise maps were coregistered among the patients to determine systematic spatial fluctuations in R2*. The contributions of minimum TE, echo spacing, signal-decay model, and region-of-interest (ROI) choice were compared in synthetic and acquired images. RESULTS: Cardiac relaxivity demonstrated characteristic circumferential variations regardless of the degree of iron overload. Within the interventricular septum, a gradient in R2* from right to left ventricle was noted at high values. Pixel-wise and ROI techniques yielded nearly identical values. Signal decay was exponential but a constant offset or second exponential term was necessary to avoid underestimation at high iron concentration. Systematic underestimation of R2* was observed for higher minimum TE, limiting the range of iron concentrations that can be profiled. Fat-water oscillations, although detectable, represented only 1% of the total signal. CONCLUSION: Clinical cardiac R2* measurements should be restricted to the interventricular septum and should have a minimum TE < or = 2 msec. ROI analysis techniques are accurate; however, offset-correction is essential.
PURPOSE: To optimize R2*(1/T2*) measurements for cardiac iron detection in sickle cell and thalassemiapatients. MATERIALS AND METHODS: We studied 31 patients with transfusion-dependent sickle cell disease and 48 patients with thalassemia major; myocardial R2* was assessed in a single midpapillary slice using a gated gradient-echo pulse sequence. Pixel-wise maps were coregistered among the patients to determine systematic spatial fluctuations in R2*. The contributions of minimum TE, echo spacing, signal-decay model, and region-of-interest (ROI) choice were compared in synthetic and acquired images. RESULTS: Cardiac relaxivity demonstrated characteristic circumferential variations regardless of the degree of iron overload. Within the interventricular septum, a gradient in R2* from right to left ventricle was noted at high values. Pixel-wise and ROI techniques yielded nearly identical values. Signal decay was exponential but a constant offset or second exponential term was necessary to avoid underestimation at high iron concentration. Systematic underestimation of R2* was observed for higher minimum TE, limiting the range of iron concentrations that can be profiled. Fat-water oscillations, although detectable, represented only 1% of the total signal. CONCLUSION: Clinical cardiac R2* measurements should be restricted to the interventricular septum and should have a minimum TE < or = 2 msec. ROI analysis techniques are accurate; however, offset-correction is essential.
Authors: C Thomsen; P Wiggers; H Ring-Larsen; E Christiansen; J Dalhøj; O Henriksen; P Christoffersen Journal: Magn Reson Imaging Date: 1992 Impact factor: 2.546
Authors: N F Olivieri; D G Nathan; J H MacMillan; A S Wayne; P P Liu; A McGee; M Martin; G Koren; A R Cohen Journal: N Engl J Med Date: 1994-09-01 Impact factor: 91.245
Authors: P Liu; M Henkelman; J Joshi; P Hardy; J Butany; M Iwanochko; M Clauberg; M Dhar; D Mai; S Waien; N Olivieri Journal: Can J Cardiol Date: 1996-02 Impact factor: 5.223
Authors: Pippa Storey; Alexis A Thompson; Christine L Carqueville; John C Wood; R Andrew de Freitas; Cynthia K Rigsby Journal: J Magn Reson Imaging Date: 2007-03 Impact factor: 4.813
Authors: Declan P O'Regan; Martina F Callaghan; Julie Fitzpatrick; Rossi P Naoumova; Joseph V Hajnal; Stephan A Schmitz Journal: Eur Radiol Date: 2007-11-23 Impact factor: 5.315
Authors: Antonella Meloni; Jon Detterich; Vasili Berdoukas; Alessia Pepe; Massimo Lombardi; Thomas D Coates; John C Wood Journal: Am J Hematol Date: 2013-02-06 Impact factor: 10.047
Authors: Taigang He; Peter D Gatehouse; Gillian C Smith; Raad H Mohiaddin; Dudley J Pennell; David N Firmin Journal: Magn Reson Med Date: 2008-11 Impact factor: 4.668
Authors: Antonella Meloni; Jon Detterich; Alessia Pepe; Paul Harmatz; Tom D Coates; John C Wood Journal: Blood Cells Mol Dis Date: 2014-11-24 Impact factor: 3.039