Total hip replacement with a zirconium oxide ceramic femoral head: a randomised roentgen stereophotogrammetric study.

T von Schewelov1, L Sanzén, I Onsten, A Carlsson, J Besjakov.   

Abstract

We investigated the wear characteristics and clinical performance of four different total hip joint articulations in 114 patients. Wear and migration was measured by roentgenstereophotogrammetric analysis at five years or at the last follow-up. The mean annual wear was 0.11 mm for a stainless steel/Enduron articulation, 0.34 mm for stainless steel/Hylamer cup, 0.17 mm for zirconium oxide ceramic/Enduron and 0.40 mm for zirconium oxide ceramic/Hylamer. The difference between the groups was significant (p < 0.008) except for stainless steel/Hylamer vs zirconium oxide ceramic/Hylamer (p = 0.26). At present, 12 patients have undergone a revision procedure, four at five years and eight thereafter. No patient who received a stainless steel/Enduron articulation at their primary replacement required revision. Conflicting results have been reported about the performance of the zirconium oxide ceramic femoral head, but our findings suggest that it should not be used with a polymethylmethacrylate acetabular component. Hylamer has already been withdrawn from the market.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16326875     DOI: 10.1302/0301-620X.87B12.16873

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  8 in total

Review 1.  Manufacturers affect clinical results of THA with zirconia heads: a systematic review.

Authors:  Hiroyuki Yoshitomi; Satoru Shikata; Hiromu Ito; Takeo Nakayama; Takashi Nakamura
Journal:  Clin Orthop Relat Res       Date:  2009-01-31       Impact factor: 4.176

2.  The Elite-Plus stem migrates more than the flanged Charnley stem.

Authors:  Thord von Schewelov; Lennart Sanzén; Jack Besjakov; Ake Carlsson
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

3.  Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.

Authors:  Maiken Stilling; Kjeld Anton Nielsen; Kjeld Søballe; Ole Rahbek
Journal:  Clin Orthop Relat Res       Date:  2009-03-27       Impact factor: 4.176

Review 4.  Comparative assessment of implantable hip devices with different bearing surfaces: systematic appraisal of evidence.

Authors:  Art Sedrakyan; Sharon-Lise T Normand; Stefan Dabic; Samantha Jacobs; Stephen Graves; Danica Marinac-Dabic
Journal:  BMJ       Date:  2011-11-29

Review 5.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

Review 6.  Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies.

Authors:  Bart G Pijls; Marc J Nieuwenhuijse; Marta Fiocco; Josepha Wm Plevier; Saskia Middeldorp; Rob Ghh Nelissen; Edward R Valstar
Journal:  Acta Orthop       Date:  2012-11-05       Impact factor: 3.717

7.  Study of the polycarbonate-urethane/metal contact in different positions during gait cycle.

Authors:  Sergio Gabarre; Antonio Herrera; Jesús Mateo; Elena Ibarz; Antonio Lobo-Escolar; Luis Gracia
Journal:  Biomed Res Int       Date:  2014-08-27       Impact factor: 3.411

Review 8.  Overview of Randomized Controlled Trials in Primary Total Hip Arthroplasty (34,020 Patients): What Have We Learnt?

Authors:  Hosam E Matar; Simon R Platt; Tim N Board; Martyn L Porter
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2020-08