Literature DB >> 16311933

Beyond heart rhythms: new directions for implantable devices.

Fred Kusumoto, Nora Goldschlager.   

Abstract

Implantable cardiac devices have become firmly entrenched as important therapeutic tools for a variety of conditions. Pacemakers are the only available treatment for symptomatic bradycardia not due to reversible causes. Large randomized studies have demonstrated a small but statistically significant reduction in atrial fibrillation associated with pacing modes that maintain atrioventricular synchrony. In contrast, pacing mode appears to have a less dramatic effect in patients with atrioventricular block. Cardiac resynchronization with specialized left ventricular leads has been shown to reduce symptoms and improve survival in patients with symptomatic heart failure, systolic dysfunction, and widened QRS complexes. The implantable cardioverter defibrillator has become the standard therapy for protecting patients against sudden cardiac death. Two recent trials, Multicenter Automatic Defibrillator Trial II (MADIT II) and the Sudden Cardiac Death Heart Failure Trial (SCD-HEFT), demonstrated that the ICD is associated with a significant survival benefit for patients with reduced ejection fraction (< 0.30-0.35) particularly if heart failure symptoms are present. Finally the implantable loop recorder has become an important diagnostic tool for the patient with unexplained syncope. This brief overview summarizes the indications and follow-up of the wide array of implantable cardiac devices available to the clinical cardiologist.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16311933     DOI: 10.1007/s10840-005-4347-2

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  10 in total

1.  Monitoring physiological variables with membrane probes.

Authors:  E M Janle; P T Kissinger
Journal:  Acta Astronaut       Date:  1998 Aug-Sep       Impact factor: 2.413

2.  Continuous amperometric monitoring of subcutaneous oxygen in rabbit by telemetry.

Authors:  W K Ward; M D Wood; E P Slobodzian
Journal:  J Med Eng Technol       Date:  2002 Jul-Aug

3.  Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable haemodynamic monitor: results of a 1 year multicentre feasibility study.

Authors:  A Ohlsson ; S H Kubo; D Steinhaus; D T Connelly; S Adler; C Bitkover; R Nordlander; L Rydén; T Bennett
Journal:  Eur Heart J       Date:  2001-06       Impact factor: 29.983

4.  Sustained hemodynamic efficacy of therapy tailored to reduce filling pressures in survivors with advanced heart failure.

Authors:  A E Steimle; L W Stevenson; C Chelimsky-Fallick; G C Fonarow; M A Hamilton; J D Moriguchi; A Kartashov; J H Tillisch
Journal:  Circulation       Date:  1997-08-19       Impact factor: 29.690

5.  Diagnosis of sleep-related breathing disorders by visual analysis of transthoracic impedance signals in pacemakers.

Authors:  Christoph Scharf; Yong K Cho; Konrad E Bloch; Corinna Brunckhorst; Firat Duru; Kryzstof Balaban; Nancy Foldvary; Lynn Liu; Richard C Burgess; Reto Candinas; Bruce L Wilkoff
Journal:  Circulation       Date:  2004-10-18       Impact factor: 29.690

6.  Ongoing right ventricular hemodynamics in heart failure: clinical value of measurements derived from an implantable monitoring system.

Authors:  Philip B Adamson; Anthony Magalski; Frieder Braunschweig; Michael Böhm; Dwight Reynolds; David Steinhaus; Allyson Luby; Cecilia Linde; Lars Ryden; Bodo Cremers; Teri Takle; Tom Bennett
Journal:  J Am Coll Cardiol       Date:  2003-02-19       Impact factor: 24.094

7.  Benefit of atrial pacing in sleep apnea syndrome.

Authors:  Stephane Garrigue; Philippe Bordier; Pierre Jaïs; Dipen C Shah; Meleze Hocini; Chantal Raherison; Manuel Tunon De Lara; Michel Haïssaguerre; Jacques Clementy
Journal:  N Engl J Med       Date:  2002-02-07       Impact factor: 91.245

8.  Continuous autonomic assessment in patients with symptomatic heart failure: prognostic value of heart rate variability measured by an implanted cardiac resynchronization device.

Authors:  Philip B Adamson; Andrew L Smith; William T Abraham; Karen J Kleckner; Robert W Stadler; Alex Shih; Melissa M Rhodes
Journal:  Circulation       Date:  2004-08-16       Impact factor: 29.690

9.  Six years follow-up of an implanted SvO(2) sensor in the right ventricle.

Authors:  Barbro Kjellström; Cecilia Linde; Tom Bennett; Ake Ohlsson; Lars Ryden
Journal:  Eur J Heart Fail       Date:  2004-08       Impact factor: 15.534

10.  Automatic recognition of abnormal respiratory events during sleep by a pacemaker transthoracic impedance sensor.

Authors:  Pascal Defaye; Jean-Louis Pépin; Yann Poezevara; Philippe Mabo; Francis Murgatroyd; Patrick Lévy; Stéphane Garrigue
Journal:  J Cardiovasc Electrophysiol       Date:  2004-09
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.