Literature DB >> 12396331

Continuous amperometric monitoring of subcutaneous oxygen in rabbit by telemetry.

W K Ward1, M D Wood, E P Slobodzian.   

Abstract

The primary objective was to develop a telemetric oxygen sensor designed for implantation in subcutaneous tissue. In the sensor, the platinum indicating electrode was covered with polythene to retard oxygen entry and avoid interference. Given the potential for large indicating electrodes to deplete oxygen in vivo, some sensors were made with very small indicating electrodes. Sensors were tested in the anesthetized rabbit at various oxygen concentrations. Animals were studied 1 and 5 days after implementation. The sensor could detect changes in oxygen in vivo. Measurements were similar at 1 and 5 days and sensors with different sized electrodes yielded similar results. This telemetric implantable amperometric sensor can detect variations in tissue oxygenation and may have applications in cardiopulmonary physiology, continuous glucose monitoring and other related fields.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12396331     DOI: 10.1080/03091900210146950

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  5 in total

1.  How to design a biosensor.

Authors:  W Kenneth Ward
Journal:  J Diabetes Sci Technol       Date:  2007-03

2.  A method for measuring brain partial pressure of oxygen in unanesthetized unrestrained subjects: the effect of acute and chronic hypoxia on brain tissue PO(2).

Authors:  E Ortiz-Prado; Siraj Natah; Sathyanarayanan Srinivasan; Jeff F Dunn
Journal:  J Neurosci Methods       Date:  2010-09-15       Impact factor: 2.390

3.  Beyond heart rhythms: new directions for implantable devices.

Authors:  Fred Kusumoto; Nora Goldschlager
Journal:  J Interv Card Electrophysiol       Date:  2005-10       Impact factor: 1.900

Review 4.  Monitoring with In Vivo Electrochemical Sensors: Navigating the Complexities of Blood and Tissue Reactivity.

Authors:  Pankaj Vadgama
Journal:  Sensors (Basel)       Date:  2020-06-02       Impact factor: 3.576

5.  Non-invasive monitoring of pH and oxygen using miniaturized electrochemical sensors in an animal model of acute hypoxia.

Authors:  Laura Pla; Sergio Berdún; Mònica Mir; Lourders Rivas; Sandrine Miserere; Samuel Dulay; Josep Samitier; Elisenda Eixarch; Miriam Illa; Eduard Gratacós
Journal:  J Transl Med       Date:  2021-02-04       Impact factor: 5.531

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.