Literature DB >> 11428818

Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable haemodynamic monitor: results of a 1 year multicentre feasibility study.

A Ohlsson 1, S H Kubo, D Steinhaus, D T Connelly, S Adler, C Bitkover, R Nordlander, L Rydén, T Bennett.   

Abstract

BACKGROUND: Implantable sensors that monitor haemodynamics over time may be useful in patients with heart failure. This multicentre study assessed the feasibility of a system that has one sensor measuring absolute pressure and another measuring mixed venous oxygen saturation (SvO(2)). Both sensors were mounted on leads that were implanted in the right ventricle.
METHODS: Twenty-one patients with heart failure (NYHA II-III) were included. Comparisons were made to right heart catheterizations at implant and at 2, 6 and 12 months thereafter. Patients underwent several haemodynamic provocations during the catheterizations.
RESULTS: Overall, among functioning sensors, the IHM-1 values were highly correlated with reference values for all time points during all provocations, demonstrating high reproducibility and stability (r(2)=0.91, 0.79 and 0.78 for systolic, right ventricular diastolic and SvO(2), respectively). Although IHM-1 underestimated reference pressure values by 4.5 mmHg and SvO(2)by 1.6%, this difference was consistent across provocation and stable over 12 months of follow-up. Twelve of the 21 oxygen sensors failed to function and two pressure sensors had component failures. Preliminary analysis of long-term data revealed haemodynamic patterns that may be key indicators for therapeutic interventions.
CONCLUSION: This multicentre feasibility study demonstrated the accuracy and stability of sensors implanted in the right ventricle. The IHM-1, using right ventricular pressures and SvO(2), with improved performance, might be useful in the study of pathophysiological mechanisms and treatment interventions in heart failure.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11428818     DOI: 10.1053/euhj.2000.2419

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  13 in total

Review 1.  Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis.

Authors:  Ramakrishna Mukkamala; Da Xu
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-07-09       Impact factor: 4.733

Review 2.  Implantable hemodynamic monitoring devices in heart failure.

Authors:  Salpy V Pamboukian; Melissa C Smallfield; Robert C Bourge
Journal:  Curr Cardiol Rep       Date:  2006-05       Impact factor: 2.931

Review 3.  Who should pay for home monitoring of heart failure?

Authors:  Monica Colvin Adams; Syed Sohail Ali
Journal:  Curr Cardiol Rep       Date:  2006-05       Impact factor: 2.931

4.  Electronic and telemedicine techniques to manage heart failure.

Authors:  Lee R Goldberg
Journal:  Curr Treat Options Cardiovasc Med       Date:  2005-08

5.  Device monitoring strategies in acute heart failure syndromes.

Authors:  Michael A Samara; W H Wilson Tang
Journal:  Heart Fail Rev       Date:  2011-09       Impact factor: 4.214

6.  Beyond heart rhythms: new directions for implantable devices.

Authors:  Fred Kusumoto; Nora Goldschlager
Journal:  J Interv Card Electrophysiol       Date:  2005-10       Impact factor: 1.900

7.  Therapeutic implications of implantable device-based monitoring of patients with heart failure.

Authors:  Eric Popjes; John P Boehmer
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-09

Review 8.  Advances in devices for cardiac resynchronization in heart failure.

Authors:  Chu-Pak Lau; Serge Barold; Hung-Fat Tse; Kathy Lai-Fun Lee; Hon-Wah Chan; Katherine Fan; Elaine Chau; Cheuk-Man Yu
Journal:  J Interv Card Electrophysiol       Date:  2003-10       Impact factor: 1.900

Review 9.  Invasive monitoring in patients with heart failure.

Authors:  Saima Husain; Salpy V Pamboukian; Josè A Tallaj; David C McGiffin; Robert C Bourge
Journal:  Curr Cardiol Rep       Date:  2009-05       Impact factor: 2.931

Review 10.  Therapeutic and diagnostic role of electrical devices in acute heart failure.

Authors:  Frieder Braunschweig
Journal:  Heart Fail Rev       Date:  2007-06       Impact factor: 4.654

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.