Literature DB >> 16303175

Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene.

Sara J Gencur1, Clare M Rimnac, Steven M Kurtz.   

Abstract

To prolong the life of total joint replacements, highly crosslinked ultra-high molecular weight polyethylenes (UHMWPEs) have been introduced to improve the wear resistance of the articulating surfaces. However, there are concerns regarding the loss of ductility and potential loss in fatigue crack propagation (FCP) resistance. The objective of this study was to evaluate the effects of gamma radiation-induced crosslinking with two different post-irradiation thermal treatments on the FCP resistance of UHMWPE. Two highly crosslinked and one virgin UHMWPE treatment groups (ram-extruded, orthopedic grade, GUR 1050) were examined. For the two highly crosslinked treatment groups, UHMWPE rods were exposed to 100 kGy and then underwent post-irradiation thermal processing either above the melt temperature or below the melt temperature (2 h-150 degrees C, 110 degrees C). Compact tension specimens were cyclically loaded to failure and the fatigue crack growth rate, da/dN, vs. cyclic stress intensity factor, DeltaK, behavior was determined and compared between groups. Scanning electron microscopy was used to examine fracture surface characteristics. Crosslinking was found to decrease the ability of UHMWPE to resist crack inception and propagation under cyclic loading. The findings also suggested that annealing as a post-irradiation treatment may be somewhat less detrimental to FCP resistance of UHMWPE than remelting. Scanning electron microscopy examination of the fracture surfaces demonstrated that the virgin treatment group failed in a more ductile manner than the two highly crosslinked treatment groups.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16303175     DOI: 10.1016/j.biomaterials.2005.09.010

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  19 in total

1.  Second-generation annealed highly cross-linked polyethylene exhibits low wear.

Authors:  James A D'Antonio; William N Capello; Rama Ramakrishnan
Journal:  Clin Orthop Relat Res       Date:  2011-12-09       Impact factor: 4.176

2.  Crack propagation resistance is similar under static and cyclic loading in crosslinked UHMWPE: a pilot study.

Authors:  Jevan Furmanski; Clare M Rimnac
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

3.  Does texturing of UHMWPE increase strength and toughness?: a pilot study.

Authors:  Frédéric Addiego; Olivier Buchheit; David Ruch; Said Ahzi; Abdesselam Dahoun
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

4.  Early failure of a cross-linked polyethylene acetabular liner. A case report.

Authors:  K David Moore; Preston R Beck; Donald W Petersen; John M Cuckler; Jack E Lemons; Alan W Eberhardt
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

5.  High stress conditions do not increase wear of thin highly crosslinked UHMWPE.

Authors:  Natalie H Kelly; Amar D Rajadhyaksha; Timothy M Wright; Suzanne A Maher; Geoffrey H Westrich
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

6.  Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Authors:  Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2013-04-25       Impact factor: 3.896

7.  Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene.

Authors:  Robert H Hopper; Henry Ho; Supatra Sritulanondha; Ann C Williams; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

Review 8.  Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior.

Authors:  M C Sobieraj; C M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2008-12-25

Review 9.  Highly cross-linked polyethylene may not have an advantage in total knee arthroplasty.

Authors:  Vasileios I Sakellariou; Peter Sculco; Lazaros Poultsides; Timothy Wright; Thomas P Sculco
Journal:  HSS J       Date:  2013-08-10

10.  UHMWPE for arthroplasty: past or future?

Authors:  Elena Maria Brach Del Prever; Alessandro Bistolfi; Pierangiola Bracco; Luigi Costa
Journal:  J Orthop Traumatol       Date:  2008-12-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.