| Literature DB >> 16289408 |
H Berrada1, J M Soriano, Y Picó, J Mañes.
Abstract
A real time quantitative PCR (RTQ-PCR) was carried out purifying DNA extracts of Listeria monocytogenes using a High Pure Listeria Sample Preparation Kit and quantifying in a LightCycler system with hybridisation probes. A standard curve was constructed with serial dilutions. A range linear relationship, from 10 to 10(5)L. monocytogenes colony forming units (CFU), was observed between threshold cycle (Ct) and logarithmic concentration of the serial dilutions. The assay was linear in a range from 10 to 10(5)L. monocytogenes CFU and the coefficient of determination (r2) was >0.98. RTQ-PCR presented an efficiency of >85%. The accuracy of the PCR-based assay, expressed as % bias, ranged from 9% to 26% and the precision, expressed as % CV, ranged 9-22%. Intraday and interday variabilities were studied at 10(2) CFU/g and resulted in 12% and 14%, respectively. The proposed RTQ-PCR method and classical cultural methods were applied to analyse 77 salads from restaurants in Valencia (Spain). All culture positive samples were also RTQ-PCR positive.Entities:
Mesh:
Substances:
Year: 2005 PMID: 16289408 DOI: 10.1016/j.ijfoodmicro.2005.07.006
Source DB: PubMed Journal: Int J Food Microbiol ISSN: 0168-1605 Impact factor: 5.277