Literature DB >> 16283150

[Multislice computed tomographic myelography].

R Klingebiel1, F Masuhr, P Rogalla, E Hein, R Juran, H C Bauknecht, G Bohner.   

Abstract

While magnetic resonance imaging (MRI) is the first line modality in depicting intramedullary spinal lesions, computed tomographic (CT) myelography has gained renewed attention due to the introduction of multislice scanning (MS-CT). Compared with conventional CT, MS-CT permits rapid, high-resolution imaging of various spinal pathologies with extended scan length. Although soft tissue contrast is inferior to that with MRI, MS-CT myelography performs best in detailed assessment of osseous pathologies, 3D imaging of orthopedic and anesthesiologic implants, and showing dural leakage and causes of CSF circulation impairment. Whenever MRI is not available or contraindicated, MS-CT myelography is the method of choice for evaluating spinal lesions.

Entities:  

Mesh:

Year:  2006        PMID: 16283150     DOI: 10.1007/s00115-005-2011-9

Source DB:  PubMed          Journal:  Nervenarzt        ISSN: 0028-2804            Impact factor:   1.214


  7 in total

1.  Subsecond multi-slice computed tomography: basics and applications.

Authors:  K Klingenbeck-Regn; S Schaller; T Flohr; B Ohnesorge; A F Kopp; U Baum
Journal:  Eur J Radiol       Date:  1999-08       Impact factor: 3.528

Review 2.  Multisection CT: scanning techniques and clinical applications.

Authors:  J Rydberg; K A Buckwalter; K S Caldemeyer; M D Phillips; D J Conces; A M Aisen; S A Persohn; K K Kopecky
Journal:  Radiographics       Date:  2000 Nov-Dec       Impact factor: 5.333

3.  [Radiation exposure in single slice and multi-slice spiral CT (a phantom study)].

Authors:  S M Giacomuzzi; P Torbica; M Rieger; C Lottersberger; S Peer; R Peer; R Perkmann; W Buchberger; R Bale; A Mallouhi; W Jaschke
Journal:  Rofo       Date:  2001-07

4.  Application of multi-detector row helical scanning to postmyelographic CT.

Authors:  Kazuhiro Tsuchiya; Shichiro Katase; Chinatsu Aoki; Junichi Hachiya
Journal:  Eur Radiol       Date:  2002-11-19       Impact factor: 5.315

Review 5.  Spine imaging.

Authors:  Cynthia T Chin
Journal:  Semin Neurol       Date:  2002-06       Impact factor: 3.420

6.  [Using multislice spiral CT in neuroradiologic imaging].

Authors:  R Klingebiel; G Bohner; C Zimmer; P Rogalla; F Masuhr; R Lehmann
Journal:  Nervenarzt       Date:  2002-08       Impact factor: 1.214

7.  Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey.

Authors:  G Brix; H D Nagel; G Stamm; R Veit; U Lechel; J Griebel; M Galanski
Journal:  Eur Radiol       Date:  2003-04-10       Impact factor: 5.315

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.