Literature DB >> 16272914

Multicenter pin care study.

Miki M Patterson1.   

Abstract

BACKGROUND: Pin-site infection is a common complication of external fixation. Because few studies have compared methods of pin care that reduce infection rate, there is a need for evidence-based practice guidelines for pin-site care.
METHODS: Two of 10 original clinical centers completed a prospective, randomized pin-care study between May 2000 and May 2002 to determine which of seven methods for caring for skeletal pins (external fixator, traction, or halo) resulted in the fewest pin-site infections.
RESULTS: The 92 subjects had an average infection rate of 34%, and the 527 pins had a rate of 20%. Thirty patients (98 pins) had stage II infections, two patients (12 pins) had stage III infections, and none had deep infection or osteomyelitis. The protocols were (1) half-strength peroxide cleansing and gauze wraps (45%), (2) half-strength peroxide cleansing and Xeroform wraps (9%), (3) saline cleansing and gauze wraps (33%), (4) saline cleansing and Xeroform wraps (26%), (5) antibacterial soap-and-water cleansing and gauze (38%), (6) antibacterial soap-and-water cleansing and Xeroform gauze (50%), and (7) stable dressings with no pin cleansing (36%). Logistic regression analysis demonstrated significant inverse relationships (p = .05) between infection rate and age, as well as fixator type; the latter may be related to exposed threads.
CONCLUSION: Results suggest that other factors outside the realm of this study may affect children's pin-site infection rate and that half-strength peroxide and Xeroform dressings were superior to soap-and-water cleansing. This pilot study indicates a need for further research with a larger sample size and for exploring factors in a younger population.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16272914     DOI: 10.1097/00006416-200509000-00011

Source DB:  PubMed          Journal:  Orthop Nurs        ISSN: 0744-6020            Impact factor:   0.913


  17 in total

1.  Perioperative management of external fixation in staged protocols: an international survey.

Authors:  Sandro Hodel; Björn-Christian Link; Reto Babst; W H Mallee; Philippe Posso; Frank J P Beeres
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-02-07

2.  A web-based survey to identify current practice in skeletal pin site management.

Authors:  Jennie A Walker; Brigitte E Scammell; Roger Bayston
Journal:  Int Wound J       Date:  2017-12-17       Impact factor: 3.315

3.  Antimicrobial gauze as a dressing reduces pin site infection: a randomized controlled trial.

Authors:  C K Lee; Y P Chua; A Saw
Journal:  Clin Orthop Relat Res       Date:  2011-08-13       Impact factor: 4.176

4.  Management of pin tract infection in pediatric supracondylar humerus fractures: a comparative study of three methods.

Authors:  Di Lu; Te Wang; Hua Chen; Liao-Jun Sun
Journal:  Eur J Pediatr       Date:  2017-03-01       Impact factor: 3.183

Review 5.  Distraction osteogenesis reconstruction of large segmental bone defects after primary tumor resection: pitfalls and benefits.

Authors:  Jan Lesensky; Daniel E Prince
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-06-22

Review 6.  Water for wound cleansing.

Authors:  Ritin Fernandez; Heidi L Green; Rhonda Griffiths; Ross A Atkinson; Laura J Ellwood
Journal:  Cochrane Database Syst Rev       Date:  2022-09-14

7.  Prevention and management of external fixator pin track sepsis.

Authors:  Nando Ferreira; Leonard Charles Marais
Journal:  Strategies Trauma Limb Reconstr       Date:  2012-06-23

8.  Seasonal Temperature and Pin Site Care Regimen Affect the Incidence of Pin Site Infection in Pediatric Supracondylar Humeral Fractures.

Authors:  Hsuan-Kai Kao; Mei-Chuan Chen; Wei-Chun Lee; Wen-E Yang; Chia-Hsieh Chang
Journal:  Biomed Res Int       Date:  2015-04-29       Impact factor: 3.411

9.  Complications of transcutaneous metal devices.

Authors:  Kristine E Kofman; Tina Buckley; Duncan A McGrouther
Journal:  Eur J Plast Surg       Date:  2011-09-15

10.  Bicondylar tibial plateau fractures treated with fine-wire circular external fixation.

Authors:  N Ferreira; L C Marais
Journal:  Strategies Trauma Limb Reconstr       Date:  2014-02-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.