Literature DB >> 16266109

Absorbed dose to water reference dosimetry using solid phantoms in the context of absorbed-dose protocols.

Jan Seuntjens1, Marina Olivares, Michael Evans, Ervin Podgorsak.   

Abstract

For reasons of phantom material reproducibility, the absorbed dose protocols of the American Association of Physicists in Medicine (AAPM) (TG-51) and the International Atomic Energy Agency (IAEA) (TRS-398) have made the use of liquid water as a phantom material for reference dosimetry mandatory. In this work we provide a formal framework for the measurement of absorbed dose to water using ionization chambers calibrated in terms of absorbed dose to water but irradiated in solid phantoms. Such a framework is useful when there is a desire to put dose measurements using solid phantoms on an absolute basis. Putting solid phantom measurements on an absolute basis has distinct advantages in verification measurements and quality assurance. We introduce a phantom dose conversion factor that converts a measurement made in a solid phantom and analyzed using an absorbed dose calibration protocol into absorbed dose to water under reference conditions. We provide techniques to measure and calculate the dose transfer from solid phantom to water. For an Exradin A12 ionization chamber, we measured and calculated the phantom dose conversion factor for six Solid Water phantoms and for a single Lucite phantom for photon energies between 60Co and 18 MV photons. For Solid Water of certified grade, the difference between measured and calculated factors varied between 0.0% and 0.7% with the average dose conversion factor being low by 0.4% compared with the calculation whereas for Lucite, the agreement was within 0.2% for the one phantom examined. The composition of commercial plastic phantoms and their homogeneity may not always be reproducible and consistent with assumed composition. By comparing measured and calculated phantom conversion factors, our work provides methods to verify the consistency of a given plastic for the purpose of clinical reference dosimetry.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16266109     DOI: 10.1118/1.2012807

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams.

Authors:  Malcolm McEwen; Larry DeWerd; Geoffrey Ibbott; David Followill; David W O Rogers; Stephen Seltzer; Jan Seuntjens
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

2.  Extrapolation chamber mounted on perspex for calibration of high energy photon and electron beams from a clinical linear accelerator.

Authors:  R Ravichandran; J P Binukumar; S S Sivakumar; K Krishnamurthy; C A Davis
Journal:  J Med Phys       Date:  2009-01

3.  Evaluation methods for detecting changes in beam output and energy in radiation beams from high-energy linear accelerators.

Authors:  R Ravichandran; J P Binukumar; C A Davis; K Krishnamurthy; S S Sivakumar
Journal:  J Med Phys       Date:  2007-07

4.  Proton radiotherapy dose perturbations caused by esophageal stents of varying material composition are negligible in an experimental model.

Authors:  Sujai Jalaj; Sang Yeob Lee; Camille McGaw; Bijo K John; Zuofeng Li; Ziad T Awad; James S Scolapio; Juan C Munoz
Journal:  Endosc Int Open       Date:  2014-10-24

5.  Dosimetric impact of density variations in Solid Water 457 water-equivalent slabs.

Authors:  Dale W Litzenberg; Hanan Amro; Joann I Prisciandaro; Eduardo Acosta; Ian Gallagher; Don A Roberts
Journal:  J Appl Clin Med Phys       Date:  2011-04-22       Impact factor: 2.102

6.  An analysis of the ArcCHECK-MR diode array's performance for ViewRay quality assurance.

Authors:  Steven T Ellefson; Wesley S Culberson; Bryan P Bednarz; Larry A DeWerd; John E Bayouth
Journal:  J Appl Clin Med Phys       Date:  2017-06-06       Impact factor: 2.102

7.  End-to-end test for computed tomography-based high-dose-rate brachytherapy.

Authors:  Fabian Krause; Franziska Risske; Susann Bohn; Marc Delaperriere; Jürgen Dunst; Frank-André Siebert
Journal:  J Contemp Brachytherapy       Date:  2018-12-28
  7 in total