Literature DB >> 16266090

4D rotational x-ray imaging of wrist joint dynamic motion.

Bart Carelsen1, Niels H Bakker, Simon D Strackee, Sjirk N Boon, Mario Maas, Jörg Sabczynski, Cornelis A Grimbergen, Geert J Streekstra.   

Abstract

Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray modalities and sophisticated 2D to 3D matching for the complex wrist joint. We present a method for the acquisition of dynamic 3D images of a moving joint. In our method a 3D-rotational x-ray (3D-RX) system is used to image a cyclically moving joint. The cyclic motion is synchronized to the x-ray acquisition to yield multiple sets of projection images, which are reconstructed to a series of time resolved 3D images, i.e., four-dimensional rotational x ray (4D-RX). To investigate the obtained image quality parameters the full width at half maximum (FWHM) of the point spread function (PSF) via the edge spread function and the contrast to noise ratio between air and phantom were determined on reconstructions of a bullet and rod phantom, using 4D-RX as well as stationary 3D-RX images. The CNR in volume reconstructions based on 251 projection images in the static situation and on 41 and 34 projection images of a moving phantom were 6.9, 3.0, and 2.9, respectively. The average FWHM of the PSF of these same images was, respectively, 1.1, 1.7, and 2.2 mm orthogonal to the motion and parallel to direction of motion 0.6, 0.7, and 1.0 mm. The main deterioration of 4D-RX images compared to 3D-RX images is due to the low number of projection images used and not to the motion of the object. Using 41 projection images seems the best setting for the current system. Experiments on a postmortem wrist show the feasibility of the method for imaging 3D dynamic joint motion. We expect that 4D-RX will pave the way to improved assessment of joint disorders by detection of 3D dynamic motion patterns in joints.

Entities:  

Mesh:

Year:  2005        PMID: 16266090     DOI: 10.1118/1.2000647

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Dynamic CT technique for assessment of wrist joint instabilities.

Authors:  Shuai Leng; Kristin Zhao; Mingliang Qu; Kai-Nan An; Richard Berger; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

2.  Understanding the relationship between image quality and motion velocity in gated computed tomography: preliminary work for 4-dimensional musculoskeletal imaging.

Authors:  Shian Chao Tay; Andrew N Primak; Joel G Fletcher; Bernhard Schmidt; Kai-Nan An; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2008 Jul-Aug       Impact factor: 1.826

3.  In vivo pilot study evaluating the thumb carpometacarpal joint during circumduction.

Authors:  Akira Goto; Shuai Leng; Kazuomi Sugamoto; William P Cooney; Sanjeev Kakar; Kristin Zhao
Journal:  Clin Orthop Relat Res       Date:  2014-04       Impact factor: 4.176

4.  Four-dimensional computed tomographic imaging in the wrist: proof of feasibility in a cadaveric model.

Authors:  Shian-Chao Tay; Andrew N Primak; Joel G Fletcher; Bernhard Schmidt; Kimberly K Amrami; Richard A Berger; Cynthia H McCollough
Journal:  Skeletal Radiol       Date:  2007-09-06       Impact factor: 2.199

5.  Four-dimensional rotational radiographic scanning of the wrist in patients after proximal row carpectomy.

Authors:  A Peymani; M Foumani; J G G Dobbe; S D Strackee; G J Streekstra
Journal:  J Hand Surg Eur Vol       Date:  2017-07-06

6.  Four-dimensional real-time cine images of wrist joint kinematics using dual source CT with minimal time increment scanning.

Authors:  Yoon Seong Choi; Young Han Lee; Sungjun Kim; Hee Woo Cho; Ho-Taek Song; Jin-Suck Suh
Journal:  Yonsei Med J       Date:  2013-07       Impact factor: 2.759

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.