| Literature DB >> 16246790 |
Takeshi Iwase1, Nobushige Tanaka.
Abstract
We report 2 cases of postoperative intraocular pressure (IOP) elevation in secondary piggyback intraocular lens (IOL) implantation without history of glaucoma or ocular hypertension. A 74-year-old woman with myopic pseudophakia and a 68-year-old man with hyperopic pseudophakia received secondary piggyback AcrySof IOL implantation in their left eyes. In both patients, the left IOP gradually increased and sustained around 30 mm Hg for about 1 year. In the first, IOP continued elevating despite topical and systemic medications. There was an episode of pupillary block in the second. Gonioscopically, heavier trabecular meshwork pigmentation in their left eyes was observed. Because of this, the 2 IOLs implanted were removed and replaced by an adequate IOL and trabeculotomy was performed in the former. The AcrySof IOL has a truncated optic edge, which increases the risk for chafing the iris, resulting in pigment dispersion syndrome; thus, it would be a poor choice for a sulcus-placed piggyback implantation.Entities:
Mesh:
Substances:
Year: 2005 PMID: 16246790 DOI: 10.1016/j.jcrs.2005.06.034
Source DB: PubMed Journal: J Cataract Refract Surg ISSN: 0886-3350 Impact factor: 3.351