Literature DB >> 16243552

Integration of digital signal processing technologies with pulsed electron paramagnetic resonance imaging.

Randall H Pursley1, Ghadi Salem, Nallathamby Devasahayam, Sankaran Subramanian, Janusz Koscielniak, Murali C Krishna, Thomas J Pohida.   

Abstract

The integration of modern data acquisition and digital signal processing (DSP) technologies with Fourier transform electron paramagnetic resonance (FT-EPR) imaging at radiofrequencies (RF) is described. The FT-EPR system operates at a Larmor frequency (L(f)) of 300MHz to facilitate in vivo studies. This relatively low frequency L(f), in conjunction with our approximately 10MHz signal bandwidth, enables the use of direct free induction decay time-locked subsampling (TLSS). This particular technique provides advantages by eliminating the traditional analog intermediate frequency downconversion stage along with the corresponding noise sources. TLSS also results in manageable sample rates that facilitate the design of DSP-based data acquisition and image processing platforms. More specifically, we utilize a high-speed field programmable gate array (FPGA) and a DSP processor to perform advanced real-time signal and image processing. The migration to a DSP-based configuration offers the benefits of improved EPR system performance, as well as increased adaptability to various EPR system configurations (i.e., software configurable systems instead of hardware reconfigurations). The required modifications to the FT-EPR system design are described, with focus on the addition of DSP technologies including the application-specific hardware, software, and firmware developed for the FPGA and DSP processor. The first results of using real-time DSP technologies in conjunction with direct detection bandpass sampling to implement EPR imaging at RF frequencies are presented.

Mesh:

Substances:

Year:  2005        PMID: 16243552      PMCID: PMC1847784          DOI: 10.1016/j.jmr.2005.10.001

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  11 in total

1.  Parallel coil resonators for time-domain radiofrequency electron paramagnetic resonance imaging of biological objects.

Authors:  N Devasahayam; S Subramanian; R Murugesan; J A Cook; M Afeworki; R G Tschudin; J B Mitchell; M C Krishna
Journal:  J Magn Reson       Date:  2000-01       Impact factor: 2.229

2.  Direct EPR detection of transient and continuous wave signals at 2.5 GHz.

Authors:  Jörg Forrer; Hansjürg Schmutz; Rene Tschaggelar; Arthur Schweiger
Journal:  J Magn Reson       Date:  2004-02       Impact factor: 2.229

3.  Single-point (constant-time) imaging in radiofrequency Fourier transform electron paramagnetic resonance.

Authors:  Sankaran Subramanian; Nallathamby Devasahayam; Ramachandran Murugesan; Kenichi Yamada; John Cook; Andrew Taube; James B Mitchell; Joost A B Lohman; Murali C Krishna
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

4.  Direct detection and time-locked subsampling applied to pulsed electron paramagnetic resonance imaging.

Authors:  Randall H Pursley; Ghadi Salem; Thomas J Pohida; Nallathamby Devasahayam; Sankaran Subramanian; Murali C Krishna
Journal:  Rev Sci Instrum       Date:  2005-05       Impact factor: 1.523

5.  In vivo imaging of a stable paramagnetic probe by pulsed-radiofrequency electron paramagnetic resonance spectroscopy.

Authors:  R Murugesan; J A Cook; N Devasahayam; M Afeworki; S Subramanian; R Tschudin; J A Larsen; J B Mitchell; A Russo; M C Krishna
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

6.  Three-dimensional whole body imaging of spin probes in mice by time-domain radiofrequency electron paramagnetic resonance.

Authors:  M Afeworki; G M van Dam; N Devasahayam; R Murugesan; J Cook; D Coffin; J H Larsen; J B Mitchell; S Subramanian; M C Krishna
Journal:  Magn Reson Med       Date:  2000-03       Impact factor: 4.668

7.  Overhauser enhanced magnetic resonance imaging for tumor oximetry: coregistration of tumor anatomy and tissue oxygen concentration.

Authors:  Murali C Krishna; Sean English; Kenichi Yamada; John Yoo; Ramachandran Murugesan; Nallathamby Devasahayam; John A Cook; Klaes Golman; Jan Henrik Ardenkjaer-Larsen; Sankaran Subramanian; James B Mitchell
Journal:  Proc Natl Acad Sci U S A       Date:  2002-02-19       Impact factor: 11.205

8.  Noninvasive in vivo oximetric imaging by radiofrequency FT EPR.

Authors:  Sankaran Subramanian; Ken-Ichi Yamada; Akira Irie; Ramachandran Murugesan; John A Cook; Nallathamby Devasahayam; Gootzian M Van Dam; James B Mitchell; Murali C Krishna
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

9.  Oxymetry deep in tissues with low-frequency electron paramagnetic resonance.

Authors:  H J Halpern; C Yu; M Peric; E Barth; D J Grdina; B A Teicher
Journal:  Proc Natl Acad Sci U S A       Date:  1994-12-20       Impact factor: 11.205

10.  Stochastic excitation and Hadamard correlation spectroscopy with bandwidth extension in RF FT-EPR.

Authors:  Randall H Pursley; John Kakareka; Ghadi Salem; Nallathamby Devasahayam; Sankaran Subramanian; Rolf G Tschudin; Murali C Krishna; Thomas J Pohida
Journal:  J Magn Reson       Date:  2003-05       Impact factor: 2.229

View more
  6 in total

1.  The world as viewed by and with unpaired electrons.

Authors:  Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2012-08-15       Impact factor: 2.229

2.  Digital EPR with an arbitrary waveform generator and direct detection at the carrier frequency.

Authors:  Mark Tseitlin; Richard W Quine; George A Rinard; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2011-09-14       Impact factor: 2.229

3.  DANCING WITH THE ELECTRONS: TIME-DOMAIN AND CW IN VIVO EPR IMAGING.

Authors:  Sankaran Subramanian; Murali C Krishna
Journal:  Magn Reson Insights       Date:  2008-09-24

4.  Digitally generated excitation and near-baseband quadrature detection of rapid scan EPR signals.

Authors:  Mark Tseitlin; Zhelin Yu; Richard W Quine; George A Rinard; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2014-10-30       Impact factor: 2.229

5.  Evaluation of partial k-space strategies to speed up time-domain EPR imaging.

Authors:  Sankaran Subramanian; Gadisetti V R Chandramouli; Alan McMillan; Rao P Gullapalli; Nallathamby Devasahayam; James B Mitchell; Shingo Matsumoto; Murali C Krishna
Journal:  Magn Reson Med       Date:  2012-10-08       Impact factor: 4.668

Review 6.  EPR Everywhere.

Authors:  Joshua R Biller; Joseph E McPeak
Journal:  Appl Magn Reson       Date:  2021-01-24       Impact factor: 0.831

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.