Literature DB >> 16235083

Fractures of the distal third of the clavicle treated by hook plating.

A D Tambe1, P Motkur, A Qamar, S Drew, S M Turner.   

Abstract

We retrospectively assessed the union and shoulder function following hook plate fixation in 18 patients with Neer type 2 fractures of the lateral end of the clavicle. The average age was 40 (range 22-62) years, and the mean follow-up was 25 (range 6-48) months. Fifteen patients had acute fractures and the rest were non-unions. Complications included two non-unions, one following a deep infection. There were no iatrogenic fractures. Acromial osteolysis was seen in five patients who had their plates in situ. The average pain score at rest was 1 (range 0-4), and the average pain score on abduction was 2.2 (range 0-5). The average Constant score was 88.5 (range 63-100). Patients were asked to rate their shoulder function; three rated it as normal, 11 as nearly normal and one as not normal. Hook plate fixation appears to be a valuable method of stabilising Neer type 2 fractures of the clavicle, resulting in high union rates and good shoulder function. These plates need to be removed after union to prevent acromial osteolysis.

Entities:  

Mesh:

Year:  2005        PMID: 16235083      PMCID: PMC2254672          DOI: 10.1007/s00264-005-0019-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  11 in total

1.  Surgical treatment of unstable fractures of the distal clavicle: a comparative study of Kirschner wire and clavicular hook plate fixation.

Authors:  Tapio Flinkkilä; Jukka Ristiniemi; Pekka Hyvönen; Martti Hämäläinen
Journal:  Acta Orthop Scand       Date:  2002-01

2.  Fracture of the distal clavicle with detachment of the coracoclavicular ligaments in adults.

Authors:  C S NEER
Journal:  J Trauma       Date:  1963-03

3.  The use of a hook-plate in the management of acromioclavicular injuries. Report of ten cases.

Authors:  A A Faraj; B Ketzer
Journal:  Acta Orthop Belg       Date:  2001-12       Impact factor: 0.500

4.  Injuries to the clavicle and acromioclavicular joint.

Authors:  R J Neviaser
Journal:  Orthop Clin North Am       Date:  1987-07       Impact factor: 2.472

5.  Coracoclavicular screw fixation for unstable fractures of the distal clavicle. A report of five cases.

Authors:  F T Ballmer; C Gerber
Journal:  J Bone Joint Surg Br       Date:  1991-03

6.  Type II distal clavicle fractures: a retrospective review of surgical treatment.

Authors:  J Kona; M J Bosse; J W Staeheli; R L Rosseau
Journal:  J Orthop Trauma       Date:  1990       Impact factor: 2.512

7.  Fractures of the distal clavicle: a case for fixation.

Authors:  D J Edwards; T G Kavanagh; M C Flannery
Journal:  Injury       Date:  1992       Impact factor: 2.586

8.  Outcome of operative treatment in fresh lateral clavicular fracture.

Authors:  A Eskola; S Vainionpää; H Pätiälä; P Rokkanen
Journal:  Ann Chir Gynaecol       Date:  1987

9.  The natural course of lateral clavicle fracture. 15 (11-21) year follow-up of 110 cases.

Authors:  A Nordqvist; C Petersson; I Redlund-Johnell
Journal:  Acta Orthop Scand       Date:  1993-02

10.  Transacromial Knowles pin in the treatment of Neer type 2 distal clavicle fracturesA prospective evaluation of 32 cases.

Authors:  Cheng-Yuh Fann; Fang-Yao Chiu; Tien-Yow Chuang; Chuan-Mu Chen; Tain-Hsiung Chen
Journal:  J Trauma       Date:  2004-05
View more
  21 in total

1.  Percutaneous fixation in fractures of the distal third of the clavicle: simpler, cheaper, better.

Authors:  Oguz Cebesoy
Journal:  Int Orthop       Date:  2006-05-25       Impact factor: 3.075

2.  Complications with the clavicle hook plate after fixation of Neer type II clavicle fractures.

Authors:  Yaiza Lopiz; Pablo Checa; Carlos García-Fernández; Jose Valle; Maria Luisa Vega; Fernando Marco
Journal:  Int Orthop       Date:  2018-08-16       Impact factor: 3.075

Review 3.  Comparison of the efficacy of a distal clavicular locking plate versus a clavicular hook plate in the treatment of unstable distal clavicle fractures and a systematic literature review.

Authors:  Chunlin Zhang; Junwu Huang; Yi Luo; Hua Sun
Journal:  Int Orthop       Date:  2014-04-15       Impact factor: 3.075

4.  Modified tension band for displaced type 2 lateral end clavicle fractures.

Authors:  Laxman Rijal; Gopal Sagar; Anshumala Joshi; Khima Nand Joshi
Journal:  Int Orthop       Date:  2012-03-06       Impact factor: 3.075

5.  [Fractures of the lateral clavicle].

Authors:  D Koppe; H Reilmann
Journal:  Unfallchirurg       Date:  2010-01       Impact factor: 1.000

6.  A technique of distal clavicle fracture fixation using the tightrope procedure.

Authors:  Cj Soh; N Sivapathasundaram; Rensgsen Parthiban; A Ramanand
Journal:  Malays Orthop J       Date:  2011-11

7.  Fixation method for treatment of unstable distal clavicle fracture: systematic review and network meta-analysis.

Authors:  Manusak Boonard; Sermsak Sumanont; Alisara Arirachakaran; Eakachit Sikarinkul; Pichet Ratanapongpean; Wichan Kanchanatawan; Jatupon Kongtharvonskul
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-03-22

Review 8.  Hook plate fixation of acute displaced lateral clavicle fractures: mid-term results and a brief literature overview.

Authors:  Davut Tiren; Alexander J M van Bemmel; Dingeman J Swank; Frits M van der Linden
Journal:  J Orthop Surg Res       Date:  2012-01-11       Impact factor: 2.359

9.  Comparison of the efficacy of hook plate versus tension band wire in the treatment of unstable fractures of the distal clavicle.

Authors:  Yih-Shiunn Lee; Ming-Jye Lau; Ya-Chun Tseng; Wen-Chiao Chen; Hsin-Yi Kao; Jyh-Ding Wei
Journal:  Int Orthop       Date:  2008-12-03       Impact factor: 3.075

10.  Evaluation of the use of the hook plate in Neer type 2 lateral clavicle fractures and Rockwood types 3-5 acromioclavicular joint dislocations.

Authors:  C C Drijfhout van Hooff; R Haverlag; W J Willems
Journal:  Eur J Trauma Emerg Surg       Date:  2013-06-27       Impact factor: 3.693

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.