Literature DB >> 16230240

Accurate femur repositioning is critical during intraoperative total hip arthroplasty length and offset assessment.

Vineet K Sarin1, William R Pratt, Gary W Bradley.   

Abstract

Techniques for intraoperative leg length equalization are based on measurements between fixed points on the pelvis and femur. These techniques have not been reliable because they are based on accurate femur repositioning. We examined the error that results from inaccurate femur repositioning during total hip arthroplasty. Total hip arthroplasty was simulated on a calibrated test bench and changes in leg length and femoral offset were measured. Before dislocation, the femur was held in neutral alignment. Total hip arthroplasty was simulated without changing length or offset and the femur was returned to neutral. Length and offset changes were measured with the femur held in 5 degrees and 10 degrees of abduction/adduction and flexion/extension. Five degrees of abduction/adduction malpositioning caused 8 mm of apparent change in leg length. Errors in femoral offset followed a similar trend. When using common techniques for intraoperative leg length equalization and offset restoration, inaccurate abduction/adduction repositioning of the femur with respect to the pelvis can cause substantial errors in the measurement of length and offset change.

Entities:  

Mesh:

Year:  2005        PMID: 16230240     DOI: 10.1016/j.arth.2004.07.001

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  17 in total

1.  Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty.

Authors:  Geert Meermans; Ahmad Malik; Johan Witt; Fares Haddad
Journal:  Clin Orthop Relat Res       Date:  2010-09-29       Impact factor: 4.176

2.  Leg length discrepancy after total hip arthroplasty: a review of literature.

Authors:  Aravind S Desai; Asterios Dramis; Tim N Board
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

3.  Leg length and offset measures with a pinless femoral reference array during THA.

Authors:  Tobias Renkawitz; Tibor Schuster; Joachim Grifka; Thomas Kalteis; Ernst Sendtner
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

4.  Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty.

Authors:  Xing Chen; Shuxing Xing; Zhiyong Zhu; Huisheng Wang; Zhongshen Yu; Xizhuang Bai; Xi Li
Journal:  Front Surg       Date:  2022-03-03

5.  Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand.

Authors:  Alfonso Manzotti; Pietro Cerveri; Elena De Momi; Chris Pullen; Norberto Confalonieri
Journal:  Int Orthop       Date:  2009-11-11       Impact factor: 3.075

6.  Serologic and radiographic outcome of total hip arthroplasty with CoCr modular neck at mid-term follow-up.

Authors:  M Chillemi; G Placella; A Caraffa; G Cerulli; P Antinolfi
Journal:  Musculoskelet Surg       Date:  2016-09-28

7.  Accurate leg length measurement in total hip arthroplasty: a comparison of computer navigation and a simple manual measurement device.

Authors:  Kyoichi Ogawa; Tamon Kabata; Toru Maeda; Yoshitomo Kajino; Hiroyuki Tsuchiya
Journal:  Clin Orthop Surg       Date:  2014-05-16

8.  Femoral neck osteotomy guide for total hip arthroplasty.

Authors:  Lei Yang; Zhanle Zheng; Wei Chen; Juan Wang; Yingze Zhang
Journal:  BMC Surg       Date:  2015-03-18       Impact factor: 2.102

9.  The clinical value of combined use of MR imaging and multi-slice spiral CT in limb salvage surgery for orthopaedic oncology patients: initial experience in nine patients.

Authors:  Jie Xu; Jun Shen; Yue Ding; Hui-Yong Shen; Zhan-Peng Zeng; Ruo-Fan Ma; Chun-Hai Li; Bertram Barden
Journal:  Radiol Oncol       Date:  2012-04-19       Impact factor: 2.991

10.  A novel intra-operative technique to achieve accurate leg length and femoral offset during total hip replacement.

Authors:  S Alazzawi; S L Douglas; F S Haddad
Journal:  Ann R Coll Surg Engl       Date:  2012-05       Impact factor: 1.951

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.