Literature DB >> 16219829

Postoperative assessment of extracranial-intracranial bypass by time-resolved 3D contrast-enhanced MR angiography using parallel imaging.

Kazuhiro Tsuchiya1, Keita Honya, Akira Fujikawa, Hidekatsu Tateishi, Yoshiaki Shiokawa.   

Abstract

PURPOSE: Our goals were to assess image quality of time-resolved contrast-enhanced MR angiography (CE MRA), by using 3D data acquisition along with a parallel imaging technique that can improve temporal resolution and to compare this technique with 3D-time-of-flight (TOF) MRA in the postoperative assessment of extracranial (EC)-intracranial (IC) bypass surgery.
METHODS: On a 1.5T imaging system, we performed CE MRA by using a 3D fast field-echo sequence in combination with a parallel imaging technique, to obtain images in the coronal plane centered at the postoperative site. Our patient group comprised 17 patients, including 13 after superficial temporal artery-middle cerebral artery (MCA) anastomosis, 3 after external carotid artery-MCA anastomosis, and one after extracranial vertebral artery-posterior cerebral artery anastomosis. Visualization of the anastomosis and the distal flow on the CE-MRA images was assessed comparatively with that on 3D-TOF MR angiograms obtained at the same time. In 6 patients, we also compared the efficiency of visualization on CE-MRA images with that on conventional angiograms.
RESULTS: A temporal resolution of 0.8 s/frame could be achieved with the technique employed. The bypass was better demonstrated postoperatively on CE-MRA images than on 3D-TOF MR angiograms in 13 patients (76%), whereas the 2 methods were equivalent in 4 patients (24%). Good correspondence of results was observed in the 6 patients for whom CE MRA and conventional digital subtraction angiography (DSA) images were compared.
CONCLUSION: CE MRA by using the parallel imaging technique can increase image acquisition speed with sufficient image quality. This technique is at least equivalent to 3D-TOF MRA to evaluate the postoperative status of EC-IC bypass.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16219829      PMCID: PMC7976149     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  21 in total

1.  Cerebral dural arteriovenous fistulas: detection by dynamic MR projection angiography.

Authors:  S G Wetzel; D Bilecen; P Lyrer; G Bongartz; E Seifritz; E W Radue; K Scheffler
Journal:  AJR Am J Roentgenol       Date:  2000-05       Impact factor: 3.959

2.  Time-resolved contrast-enhanced carotid MR angiography using sensitivity encoding (SENSE).

Authors:  X Golay; S J Brown; R Itoh; E R Melhem
Journal:  AJNR Am J Neuroradiol       Date:  2001-09       Impact factor: 3.825

3.  Intraoperative sonographic assessment of graft patency during extracranial-intracranial bypass.

Authors:  B Badie; F T Lee; M A Pozniak; C M Strother
Journal:  AJNR Am J Neuroradiol       Date:  2000-09       Impact factor: 3.825

4.  Description of parallel imaging in MRI using multiple coils.

Authors:  Y Wang
Journal:  Magn Reson Med       Date:  2000-09       Impact factor: 4.668

5.  MR digital subtraction angiography with three-dimensional data acquisition in the diagnosis of brain tumors: preliminary experience.

Authors:  Kazuhiro Tsuchiya; Chinatsu Aoki; Shichiro Katase; Junichi Hachiya
Journal:  Magn Reson Imaging       Date:  2004-02       Impact factor: 2.546

6.  Postoperative evaluation of extracranial-intracranial arterial bypass by means of ultrasonic quantitative flow measurement and computed mapping of the electroencephalogram.

Authors:  A Hyodo; M Mizukami; T Kawase; K Nagata; K Yunoki; K Yamaguchi
Journal:  Neurosurgery       Date:  1984-09       Impact factor: 4.654

7.  Superficial temporal artery--middle cerebral artery anastomosis for acute cerebral ischemia: the effect of small augmentation of blood flow.

Authors:  Y Yoshimoto; S Kwak
Journal:  Acta Neurochir (Wien)       Date:  1995       Impact factor: 2.216

8.  Visualization of extracranial-intracranial bypass using multidetector-row helical computed tomography angiography.

Authors:  Kazuhiro Tsuchiya; Chinatsu Aoki; Shichiro Katase; Junichi Hachiya; Yoshiaki Shiokawa
Journal:  J Comput Assist Tomogr       Date:  2003 Mar-Apr       Impact factor: 1.826

9.  Brain arteriovenous malformations: assessment with dynamic MR digital subtraction angiography.

Authors:  P D Griffiths; N Hoggard; D J Warren; I D Wilkinson; B Anderson; C A Romanowski
Journal:  AJNR Am J Neuroradiol       Date:  2000 Nov-Dec       Impact factor: 3.825

Review 10.  Stroke: indications for emergent surgical intervention.

Authors:  H J Pikus; R C Heros
Journal:  Clin Neurosurg       Date:  1999
View more
  4 in total

1.  3D time-resolved MR angiography (MRA) of the carotid arteries with time-resolved imaging with stochastic trajectories: comparison with 3D contrast-enhanced Bolus-Chase MRA and 3D time-of-flight MRA.

Authors:  R P Lim; M Shapiro; E Y Wang; M Law; J S Babb; L E Rueff; J S Jacob; S Kim; R H Carson; T P Mulholland; G Laub; E M Hecht
Journal:  AJNR Am J Neuroradiol       Date:  2008-09-03       Impact factor: 3.825

2.  Dual energy bone subtraction in computed tomography angiography of extracranial-intracranial bypass: feasibility and limitations.

Authors:  André Kemmling; Ingo Nölte; Christoph Groden; Steffen Diehl
Journal:  Eur Radiol       Date:  2010-10-04       Impact factor: 5.315

3.  4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics.

Authors:  Tetsuro Sekine; Ryo Takagi; Yasuo Amano; Yasuo Murai; Erika Orita; Yoshio Matsumura; Shin-Ichiro Kumita
Journal:  Neuroradiology       Date:  2015-12-02       Impact factor: 2.804

4.  Time-resolved 3D contrast-enhanced MRA on 3.0T: a non-invasive follow-up technique after stent-assisted coil embolization of the intracranial aneurysm.

Authors:  Jin Woo Choi; Hong Gee Roh; Won-Jin Moon; Na Ra Kim; Sung Gyu Moon; Chung Hwan Kang; Young Il Chun; Hyun-Seung Kang
Journal:  Korean J Radiol       Date:  2011-09-27       Impact factor: 3.500

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.