Literature DB >> 16214398

Development and evaluation of a real-time RT-PCR assay on the LightCycler for the rapid detection of enterovirus in cerebrospinal fluid specimens.

J Petitjean1, A Vabret, J Dina, S Gouarin, F Freymuth.   

Abstract

BACKGROUND: Detection of enteroviral nucleic acid in cerebrospinal fluid (CSF) specimens has been demonstrated to improve the management of patients with aseptic meningitis.
OBJECTIVE: To develop on the LightCycler (LC) instrument a real-time RT-PCR assay based on TaqMan technology for the detection of enteroviruses (EV) in cerebrospinal fluid (CSF) specimens. STUDY
DESIGN: After evaluation of the analytical performances, seventy-four CSF samples collected prospectively from patients who have been suspected for a clinical diagnosis of meningitis were evaluated by two LC real-time RT-PCR assays and one conventional RT-PCR assay.
RESULTS: Our assay detected all 30 different EV species tested, whereas no reactivity was observed with other neurotropic viruses. The analytical sensitivity of both LC RT-PCR real-time assays was 1 TCID50 for LC one-step and two-step RT-PCR assays. Results for LC one-step and LC two-step RT-PCR were compared to results of the conventional RT-PCR: of the 74 CSF specimens tested, 11 were positive and 56 were negative by all methods. Four other specimens were positive for EV by at least two of the methods (including the LC two-step RT-PCR and the conventional RT-PCR), two other CSF specimens were positive by the LC two-step RT-PCR assay only, and another one CSF specimen was positive by the LC one-step RT-PCR assay only. No CSF specimens were negative by the LC two-step RT-PCR assay and positive by the conventional RT-PCR assay. The sensitivity, specificity, positive and negative predictive values of both LC RT-PCR assays by using conventional RT-PCR as the "gold standard" were, respectively, 73.3, 98.3, 91.7, 93.5% for the LC one-step RT-PCR and 100, 96.6, 88.2, 100% for the LC two-step RT-PCR. There was substantial agreement between the three assays (k=0.80).
CONCLUSIONS: The LC two-step RT-PCR assay is a rapid, sensitive and reliable method which can be routinely performed with CSF samples for diagnosis of EV infection and is an important improvement for optimal patient management.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16214398     DOI: 10.1016/j.jcv.2005.09.006

Source DB:  PubMed          Journal:  J Clin Virol        ISSN: 1386-6532            Impact factor:   3.168


  14 in total

1.  Evaluation of LightCycler as a platform for nucleic acid sequence-based amplification (NASBA) in real-time detection of enteroviruses.

Authors:  Anna-Maria Costa; David Lamb; Suzanne M Garland; Sepehr N Tabrizi
Journal:  Curr Microbiol       Date:  2007-10-02       Impact factor: 2.188

2.  A TaqMan reverse transcription polymerase chain reaction (RT-PCR) in vitro potency assay for plasmid-based vaccine products.

Authors:  Rohit Mahajan; Beth Feher; Basil Jones; Doug Jones; Lana Marjerison; Mindy Sam; Jukka Hartikka; Mary Wloch; Peggy Lalor; David Kaslow; Keith Hall; Alain Rolland
Journal:  Mol Biotechnol       Date:  2008-03-26       Impact factor: 2.695

3.  Enhanced detection of enteroviruses in clinical samples by reverse transcription-PCR using complementary locked primer technology.

Authors:  JiYoung Hong; Byunghak Kang; Ahyoun Kim; Seoyoun Hwang; Sunwha Lee; Jonghyen Kim; Hyun-Young Lee; Sang-Hyeon Kang; Doo-Sung Cheon
Journal:  J Clin Microbiol       Date:  2009-11-25       Impact factor: 5.948

4.  Virus detection and semiquantitation in explanted heart tissues of idiopathic dilated cardiomyopathy adult patients by use of PCR coupled with mass spectrometry analysis.

Authors:  Yohan Nguyen; Fanny Renois; Nicolas Leveque; Delphine Giusti; Marcus Picard-Maureau; Patrick Bruneval; Paul Fornes; Laurent Andreoletti
Journal:  J Clin Microbiol       Date:  2013-05-08       Impact factor: 5.948

5.  Enterovirus 68 in pediatric patients hospitalized for acute airway diseases.

Authors:  Fanny Renois; Alexis Bouin; Laurent Andreoletti
Journal:  J Clin Microbiol       Date:  2012-12-05       Impact factor: 5.948

6.  Development of a reverse transcription-quantitative PCR assay for detection of salivirus/klassevirus.

Authors:  Eiji Haramoto; Masaaki Kitajima; Mikie Otagiri
Journal:  Appl Environ Microbiol       Date:  2013-03-29       Impact factor: 4.792

7.  Rapid detection and quantitation of poliovirus and rhinovirus sequences in viral stocks and infected cells.

Authors:  Swathi Kotla; Stephanie C Major; Kurt E Gustin
Journal:  J Virol Methods       Date:  2009-01-16       Impact factor: 2.014

8.  Occurrence of Human Cosavirus in Wastewater and River Water in Japan.

Authors:  Eiji Haramoto; Mikie Otagiri
Journal:  Food Environ Virol       Date:  2013-08-13       Impact factor: 2.778

9.  Development of a highly sensitive real-time one step RT-PCR combined complementary locked primer technology and conjugated minor groove binder probe.

Authors:  JiYoung Hong; Byunghak Kang; Ahyoun Kim; Seoyeon Hwang; Jinhee Ahn; Sunhwa Lee; Jonghyen Kim; Jae-Hak Park; Doo-Sung Cheon
Journal:  Virol J       Date:  2011-06-29       Impact factor: 4.099

10.  Rapid and sensitive identification of RNA from the emerging pathogen, coxsackievirus A6.

Authors:  Lei Zhang; Xinying Wang; Yanjun Zhang; Liming Gong; Haiyan Mao; Cen Feng; David M Ojcius; Jie Yan
Journal:  Virol J       Date:  2012-11-30       Impact factor: 4.099

View more