Literature DB >> 16206144

Placement of deep brain stimulator electrodes using real-time high-field interventional magnetic resonance imaging.

Alastair J Martin1, Paul S Larson, Jill L Ostrem, W Keith Sootsman, Pekka Talke, Oliver M Weber, Nadja Levesque, Jeffrey Myers, Philip A Starr.   

Abstract

A methodology is presented for placing deep brain stimulator electrodes under direct MR image guidance. The technique utilized a small, skull-mounted trajectory guide that is optimized for accurate alignment under MR fluoroscopy. Iterative confirmation scans are used to monitor device alignment and brain penetration. The methodology was initially tested in a human skull phantom and proved capable of achieving submillimeter accuracy over a set of 16 separate targets that were accessed. The maximum error that was obtained in this preliminary test was 2 mm, motivating use of the technique in a clinical study. Subsequently, a total of eight deep brain stimulation electrodes were placed in five patients. Satisfactory placement was achieved on the first pass in seven of eight electrodes, while two passes were required with one electrode. Mean error from the intended target on the first pass was 1.0 +/- 0.8 mm (range = 0.1-1.9 mm). All procedures were considered technical successes and there were no intraoperative complications; however, one patient did develop a postoperative infection. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16206144     DOI: 10.1002/mrm.20675

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  Interventional loopless antenna at 7 T.

Authors:  Mehmet Arcan Ertürk; Abdel-Monem M El-Sharkawy; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

Review 2.  Parkinson's disease therapeutics: new developments and challenges since the introduction of levodopa.

Authors:  Yoland Smith; Thomas Wichmann; Stewart A Factor; Mahlon R DeLong
Journal:  Neuropsychopharmacology       Date:  2011-09-28       Impact factor: 7.853

3.  Novel platform for MRI-guided convection-enhanced delivery of therapeutics: preclinical validation in nonhuman primate brain.

Authors:  R Mark Richardson; Adrian P Kells; Alastair J Martin; Paul S Larson; Philip A Starr; Peter G Piferi; Geoffrey Bates; Lisa Tansey; Kathryn H Rosenbluth; John R Bringas; Mitchel S Berger; Krystof S Bankiewicz
Journal:  Stereotact Funct Neurosurg       Date:  2011-04-14       Impact factor: 1.875

4.  Accuracy of flat panel detector CT with integrated navigational software with and without MR fusion for single-pass needle placement.

Authors:  Marc C Mabray; Sanjit Datta; Prasheel V Lillaney; Teri Moore; Sonja Gehrisch; Jason F Talbott; Michael R Levitt; Basavaraj V Ghodke; Paul S Larson; Daniel L Cooke
Journal:  J Neurointerv Surg       Date:  2015-06-05       Impact factor: 5.836

5.  A Platform Integrating Acquisition, Reconstruction, Visualization, and Manipulator Control Modules for MRI-Guided Interventions.

Authors:  Jose D Velazco Garcia; Nikhil V Navkar; Dawei Gui; Cristina M Morales; Eftychios G Christoforou; Alpay Ozcan; Julien Abinahed; Abdulla Al-Ansari; Andrew Webb; Ioannis Seimenis; Nikolaos V Tsekos
Journal:  J Digit Imaging       Date:  2019-06       Impact factor: 4.056

6.  Concurrent multiscale imaging with magnetic resonance imaging and optical coherence tomography.

Authors:  Chia-Pin Liang; Bo Yang; Il Kyoon Kim; George Makris; Jaydev P Desai; Rao P Gullapalli; Yu Chen
Journal:  J Biomed Opt       Date:  2013-04       Impact factor: 3.170

7.  A Fabry-Perot Interferometry Based MRI-Compatible Miniature Uniaxial Force Sensor for Percutaneous Needle Placement.

Authors:  Weijian Shang; Hao Su; Gang Li; Cosme Furlong; Gregory S Fischer
Journal:  Proc IEEE Sens       Date:  2013

8.  Venous Thromboembolism during Interventional MRI-Guided Stereotactic Surgery.

Authors:  Adam J Kundishora; Dario J Englot; Philip A Starr; Alastair J Martin; Paul S Larson
Journal:  Stereotact Funct Neurosurg       Date:  2018-03-01       Impact factor: 1.875

Review 9.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11

10.  A modified stereotactic frame as an instrument holder for frameless stereotaxis: Technical note.

Authors:  Arun Angelo Patil
Journal:  Surg Neurol Int       Date:  2010-10-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.