Literature DB >> 16200554

Multitensor approach for analysis and tracking of complex fiber configurations.

B W Kreher1, J F Schneider, I Mader, E Martin, J Hennig, K A Il'yasov.   

Abstract

A multidiffusion-tensor model (MDT) is presented containing two anisotropic and one isotropic diffusion tensors. This approach has the ability to detect areas of fiber crossings and resolve the direction of crossing fibers. The mean diffusivity and the ratio of the tensor compartments were merged to one independent parameter by fitting MDT to the diffusion-weighted intensities of a two-point data acquisition scheme. By an F-test between the errors of the standard single diffusion tensor and the more complex MDT, fiber crossings were detected and the more accurate model was chosen voxel by voxel. The performance of crossing detection was compared with the spherical harmonics approach in simulations as well as in vivo. Similar results were found in both methods. The MDT model, however, did not only detect crossings but also yielded the single fiber directions. The FACT algorithm and a probabilistic connectivity algorithm were extended to support the MDT model. For example, a mean angular error smaller than 10 degrees was found for the MDT model in a simulated fiber crossing with an SNR of 80. By tracking the corticospinal tract the MDT-based tracks reached a significantly greater area of the gyrus precentralis. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16200554     DOI: 10.1002/mrm.20670

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  39 in total

1.  Somatotopic organization of motor pathways in the internal capsule: a probabilistic diffusion tractography study.

Authors:  C Pan; K K Peck; R J Young; A I Holodny
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-29       Impact factor: 3.825

2.  Two-tensor tractography using a constrained filter.

Authors:  James G Malcolm; Martha E Shenton; Yogesh Rathi
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

3.  Microstructural development: organizational differences of the fiber architecture between children and adults in dorsal and ventral visual streams.

Authors:  Thomas Loenneker; Peter Klaver; Kerstin Bucher; Janine Lichtensteiger; Adrian Imfeld; Ernst Martin
Journal:  Hum Brain Mapp       Date:  2010-06-09       Impact factor: 5.038

Review 4.  Principles and limitations of computational algorithms in clinical diffusion tensor MR tractography.

Authors:  H-W Chung; M-C Chou; C-Y Chen
Journal:  AJNR Am J Neuroradiol       Date:  2010-03-18       Impact factor: 3.825

5.  Optimal real-time estimation in diffusion tensor imaging.

Authors:  Pablo Casaseca-de-la-Higuera; Antonio Tristán-Vega; Santiago Aja-Fernández; Carlos Alberola-López; Carl-Fredrik Westin; Raúl San José Estépar
Journal:  Magn Reson Imaging       Date:  2012-02-02       Impact factor: 2.546

6.  Reliable selection of the number of fascicles in diffusion images by estimation of the generalization error.

Authors:  Benoit Scherrer; Maxime Taquet; Simon K Warfield
Journal:  Inf Process Med Imaging       Date:  2013

7.  Ball and rackets: Inferring fiber fanning from diffusion-weighted MRI.

Authors:  Stamatios N Sotiropoulos; Timothy E J Behrens; Saad Jbabdi
Journal:  Neuroimage       Date:  2012-01-14       Impact factor: 6.556

8.  Multi-diffusion-tensor fitting via spherical deconvolution: a unifying framework.

Authors:  Thomas Schultz; Carl-Fredrik Westin; Gordon Kindlmann
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

9.  Multitensor tractography enables better depiction of motor pathways: initial clinical experience using diffusion-weighted MR imaging with standard b-value.

Authors:  K Yamada; K Sakai; F G C Hoogenraad; R Holthuizen; K Akazawa; H Ito; H Oouchi; S Matsushima; T Kubota; H Sasajima; K Mineura; T Nishimura
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-20       Impact factor: 3.825

10.  A full bi-tensor neural tractography algorithm using the unscented Kalman filter.

Authors:  Stefan Lienhard; James G Malcolm; Carl-Frederik Westin; Yogesh Rathi
Journal:  EURASIP J Adv Signal Process       Date:  2011-01-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.