Abstract

The introduction of digital radiological facilities leads to the necessity of digital preoperative planning, which is an essential part of joint replacement surgery. To avoid errors in the preparation and execution of hip surgery, reliable correction of the magnification of the projected hip is a prerequisite. So far, no validated method exists to accomplish this. We present validated geometrical models of the x-ray projection of spheres, relevant for the calibration procedure to correct for the radiographic magnification. With help of these models a new calibration protocol was developed. The validity and precision of this procedure was determined in clinical practice. Magnification factors could be predicted with a maximal margin of error of 1.5%. The new calibration protocol is valid and reliable. The clinical tests revealed that correction of magnification has a 95% margin of error of -3% to +3%. Future research might clarify if a strict calibration protocol, as presented in this study, results in more accurate preoperative planning of hip joint replacements.

Entities:  

Mesh:

Year:  2005        PMID: 16193788     DOI: 10.1118/1.1984293

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Comparison of techniques for correction of magnification of pelvic X-rays for hip surgery planning.

Authors:  Bertram The; Johan W J Kootstra; Anton H Hosman; Nico Verdonschot; Carina L E Gerritsma; Ron L Diercks
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

2.  Design and implementation of gradient vector flow snake to detect a reference object in pelvic x-rays for preoperative total hip arthroplasty planning application.

Authors:  W Kristanto; P M A van Ooijen; B The; H Duifhuis; T R Mengko; M Oudkerk
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

3.  The utility and precision of analogue and digital preoperative planning for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Nicole Taveras; Eduardo A Salvati
Journal:  Int Orthop       Date:  2007-04-03       Impact factor: 3.075

4.  Determination of digitised radiograph magnification factors for pre-operative templating in hip prosthesis surgery.

Authors:  Stephane Descamps; Christine Livesey; Ian Douglas Learmonth
Journal:  Skeletal Radiol       Date:  2009-09-16       Impact factor: 2.199

5.  DICOM for implantations--overview and application.

Authors:  Thomas Treichel; Michael Gessat; Torsten Prietzel; Oliver Burgert
Journal:  J Digit Imaging       Date:  2012-06       Impact factor: 4.056

6.  Digital templating in total knee and hip replacement: an analysis of planning accuracy.

Authors:  Bettina Kniesel; Lukas Konstantinidis; Anja Hirschmüller; Norbert Südkamp; Peter Helwig
Journal:  Int Orthop       Date:  2013-10-27       Impact factor: 3.075

7.  Effectiveness of computer-navigated minimally invasive total hip surgery compared to conventional total hip arthroplasty: design of a randomized controlled trial.

Authors:  Inge H F Reininga; Robert Wagenmakers; Inge van den Akker-Scheek; A Dennis Stant; Johan W Groothoff; Sjoerd K Bulstra; Wiebren Zijlstra; Martin Stevens
Journal:  BMC Musculoskelet Disord       Date:  2007-01-11       Impact factor: 2.362

8.  Calibration Markers for Digital Templating in Total Hip Arthroplasty.

Authors:  Christoph Kolja Boese; Philipp Lechler; Leonard Rose; Jens Dargel; Johannes Oppermann; Peer Eysel; Hansjörg Geiges; Jan Bredow
Journal:  PLoS One       Date:  2015-07-13       Impact factor: 3.240

9.  A new digital preoperative planning method for total hip arthroplasties.

Authors:  Hendrikus J A Crooijmans; Armand M R P Laumen; Carola van Pul; Jan B A van Mourik
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

10.  Magnification of digital hip radiographs differs between clinical workplaces.

Authors:  Jana Hornová; Pavel Růžička; Maroš Hrubina; Eduard Šťastný; Andrea Košková; Petr Fulín; Jiří Gallo; Matej Daniel
Journal:  PLoS One       Date:  2017-11-30       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.