Dose distribution from x-ray microbeam arrays applied to radiation therapy: an EGS4 Monte Carlo study.

M De Felici1, R Felici, M Sanchez del Rio, C Ferrero, T Bacarian, F A Dilmanian.   

Abstract

We present EGS4 Monte Carlo calculations of the spatial distribution of the dose deposited by a single x-ray pencil beam, a planar microbeam, and an array of parallel planar microbeams as used in radiation therapy research. The profiles of the absorbed dose distribution in a phantom, including the peak-to-valley ratio of the dose distribution from microbeam arrays, were calculated at micrometer resolution. We determined the dependence of the findings on the main parameters of photon and electron transport. The results illustrate the dependence of the electron range and the deposited in-beam dose on the cut-off energy, of the electron transport, as well as the effects on the dose profiles of the beam energy, the array size, and the beam spacing. The effect of beam polarization also was studied for a single pencil beam and for an array of parallel planar microbeams. The results show that although the polarization effect on the dose distribution from a 3 cm x 3 cm microbeam array inside a water phantom is large enough to be measured at the outer side of the array (16% difference of the deposited dose for x-ray beams of 200 keV), it is not detectable at the array's center, thus being irrelevant for the radiation therapy purposes. Finally we show that to properly compare the dose profiles determined with a metal oxide semiconductor field emission transistor detector with the computational method predictions, it is important to simulate adequately the size and the material of the device's Si active element.

Entities:  

Mesh:

Year:  2005        PMID: 16193774     DOI: 10.1118/1.1951043

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Pilot study for compact microbeam radiation therapy using a carbon nanotube field emission micro-CT scanner.

Authors:  Mike Hadsell; Guohua Cao; Jian Zhang; Laurel Burk; Torsten Schreiber; Eric Schreiber; Sha Chang; Jianping Lu; Otto Zhou
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

2.  Interlaced x-ray microplanar beams: a radiosurgery approach with clinical potential.

Authors:  F Avraham Dilmanian; Zhong Zhong; Tigran Bacarian; Helene Benveniste; Pantaleo Romanelli; Ruiliang Wang; Jeremy Welwart; Tetsuya Yuasa; Eliot M Rosen; David J Anschel
Journal:  Proc Natl Acad Sci U S A       Date:  2006-06-07       Impact factor: 11.205

3.  A first generation compact microbeam radiation therapy system based on carbon nanotube X-ray technology.

Authors:  M Hadsell; J Zhang; P Laganis; F Sprenger; J Shan; L Zhang; L Burk; H Yuan; S Chang; J Lu; O Zhou
Journal:  Appl Phys Lett       Date:  2013-10-30       Impact factor: 3.791

4.  Evaluating the peak-to-valley dose ratio of synchrotron microbeams using PRESAGE fluorescence.

Authors:  N Annabell; N Yagi; K Umetani; C Wong; M Geso
Journal:  J Synchrotron Radiat       Date:  2012-03-15       Impact factor: 2.616

5.  Monte Carlo simulation of a compact microbeam radiotherapy system based on carbon nanotube field emission technology.

Authors:  Eric C Schreiber; Sha X Chang
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.506

6.  Hybrid dose calculation: a dose calculation algorithm for microbeam radiation therapy.

Authors:  Mattia Donzelli; Elke Bräuer-Krisch; Uwe Oelfke; Jan J Wilkens; Stefan Bartzsch
Journal:  Phys Med Biol       Date:  2018-02-13       Impact factor: 3.609

7.  Investigating the Dosimetric Characteristics of Microbeam Radiation Treatment.

Authors:  Mansour Zabihzadeh; Atefeh Rabiei; Hojattollah Shahbazian; Sasan Razmjoo
Journal:  J Med Signals Sens       Date:  2021-01-30

8.  Treatment Planning Study for Microbeam Radiotherapy Using Clinical Patient Data.

Authors:  Kim Melanie Kraus; Johanna Winter; Yating Zhang; Mabroor Ahmed; Stephanie Elisabeth Combs; Jan Jakob Wilkens; Stefan Bartzsch
Journal:  Cancers (Basel)       Date:  2022-01-28       Impact factor: 6.639

9.  A high-resolution dose calculation engine for X-ray microbeams radiation therapy.

Authors:  Sarvenaz Keshmiri; Sylvan Brocard; Raphaël Serduc; Jean-François Adam
Journal:  Med Phys       Date:  2022-04-12       Impact factor: 4.506

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.