Literature DB >> 16189992

Chemical and microbial exposures in a school building: adverse health effects in children.

Tuula Putus1, Anneli Tuomainen, Sirpa Rautiala.   

Abstract

In this cross-sectional study, the authors examined the relationship between an unusual combination of indoor air contaminants in a school and adverse health effects among the attending children. A leaking roof and damp floors, together with gaseous leaks from the sewage system, led to a combined exposure of hydrocarbons, 2-ethylhexanol from plastic floor coverings, and moisture-associated microbes. The health status of 274 children in the school was assessed via repeated symptom questionnaires. Statistical analysis revealed a relationship between the indoor air contaminants and adverse health outcomes such as respiratory irritation, asthmatic symptoms, eye and general symptoms, and increased occurrence of common viral respiratory infections. No association was found between the exposures and doctor-diagnosed asthma, other allergic diseases, or bacterial respiratory infections. Chemical contaminants from the sewer system and damp construction materials were identified as the source of the problem. Remediation of the school building improved the indoor air quality and the health status of the children.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 16189992     DOI: 10.3200/AEOH.59.4.194-201

Source DB:  PubMed          Journal:  Arch Environ Health        ISSN: 0003-9896


  5 in total

1.  Indoor air quality differences between urban and rural preschools in Korea.

Authors:  Chungsik Yoon; Kiyoung Lee; Donguk Park
Journal:  Environ Sci Pollut Res Int       Date:  2010-07-29       Impact factor: 4.223

Review 2.  Comprehensive review of 2-ethyl-1-hexanol as an indoor air pollutant.

Authors:  Takanari Wakayama; Yuki Ito; Kiyoshi Sakai; Mio Miyake; Eiji Shibata; Hiroyuki Ohno; Michihiro Kamijima
Journal:  J Occup Health       Date:  2019-01       Impact factor: 2.708

3.  Indoor Particulate Matters, Microbial Count Assessments, and Wheezing Symptoms among Toddlers in Urban Day Care Centers in the District of Seremban, Malaysia.

Authors:  Raihan Khamal; Zaleha Md Isa; Rosnah Sutan; Nor Mohd Razif Noraini; Hasanain Faisal Ghazi
Journal:  Ann Glob Health       Date:  2019-01-22       Impact factor: 2.462

4.  Associations between indoor environmental quality in schools and symptom reporting in pupil-administered questionnaires.

Authors:  Kateryna Savelieva; Tero Marttila; Jussi Lampi; Sari Ung-Lanki; Marko Elovainio; Juha Pekkanen
Journal:  Environ Health       Date:  2019-12-27       Impact factor: 5.984

5.  Psychosocial factors and indoor environmental quality in respiratory symptom reports of pupils: a cross-sectional study in Finnish schools.

Authors:  Kateryna Savelieva; Marko Elovainio; Jussi Lampi; Sari Ung-Lanki; Juha Pekkanen
Journal:  BMJ Open       Date:  2020-09-21       Impact factor: 2.692

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.