Literature DB >> 16187273

Design of flyback echo-planar readout gradients for magnetic resonance spectroscopic imaging.

Charles H Cunningham1, Daniel B Vigneron, Albert P Chen, Duan Xu, Sarah J Nelson, Ralph E Hurd, Douglas A Kelley, John M Pauly.   

Abstract

The spatial resolution of conventional magnetic resonance spectroscopic imaging-(MRSI) is typically coarse, mainly due to SNR limitations. The increased signal available with higher field scanners and new array coils now permits higher spatial resolution, but conventional chemical shift imaging (phase encoding) limits the spatial coverage possible in a patient-acceptable acquisition time. The "flyback" echo-planar trajectory is particularly insensitive to errors and provides data that are simple to process. In this study, high-efficiency gradient waveforms for flyback echo-planar MRSI were designed and implemented. Normal volunteer studies at 3 T showed the feasibility of acquiring high spatial resolution with large coverage in a short scan time (2048 voxels in 2.3 min and 4096 voxels in 8.5 min). The trajectories were insensitive to errors in timing and require only a modest (10 to 30%) penalty in SNR relative to conventional phase encoding using the same acquisition time. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16187273     DOI: 10.1002/mrm.20663

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  53 in total

1.  MR spectroscopy of normative premature newborns.

Authors:  Duan Xu; Sonia L Bonifacio; Natalie N Charlton; Charles P Vaughan; Ying Lu; Donna M Ferriero; Daniel B Vigneron; A James Barkovich
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

2.  Fast multivoxel two-dimensional spectroscopic imaging at 3 T.

Authors:  Dong-Hyun Kim; Roland Henry; Daniel M Spielman
Journal:  Magn Reson Imaging       Date:  2007-04-05       Impact factor: 2.546

3.  Compressed sensing for resolution enhancement of hyperpolarized 13C flyback 3D-MRSI.

Authors:  Simon Hu; Michael Lustig; Albert P Chen; Jason Crane; Adam Kerr; Douglas A C Kelley; Ralph Hurd; John Kurhanewicz; Sarah J Nelson; John M Pauly; Daniel B Vigneron
Journal:  J Magn Reson       Date:  2008-03-18       Impact factor: 2.229

4.  Investigation of tumor hyperpolarized [1-13C]-pyruvate dynamics using time-resolved multiband RF excitation echo-planar MRSI.

Authors:  Peder E Z Larson; Robert Bok; Adam B Kerr; Michael Lustig; Simon Hu; Albert P Chen; Sarah J Nelson; John M Pauly; John Kurhanewicz; Daniel B Vigneron
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

5.  Fully automated atlas-based method for prescribing 3D PRESS MR spectroscopic imaging: Toward robust and reproducible metabolite measurements in human brain.

Authors:  Wei Bian; Yan Li; Jason C Crane; Sarah J Nelson
Journal:  Magn Reson Med       Date:  2017-05-03       Impact factor: 4.668

6.  Kinetic modeling of hyperpolarized 13C1-pyruvate metabolism in normal rats and TRAMP mice.

Authors:  Matthew L Zierhut; Yi-Fen Yen; Albert P Chen; Robert Bok; Mark J Albers; Vickie Zhang; Jim Tropp; Ilwoo Park; Daniel B Vigneron; John Kurhanewicz; Ralph E Hurd; Sarah J Nelson
Journal:  J Magn Reson       Date:  2009-10-13       Impact factor: 2.229

7.  3D compressed sensing for highly accelerated hyperpolarized (13)C MRSI with in vivo applications to transgenic mouse models of cancer.

Authors:  Simon Hu; Michael Lustig; Asha Balakrishnan; Peder E Z Larson; Robert Bok; John Kurhanewicz; Sarah J Nelson; Andrei Goga; John M Pauly; Daniel B Vigneron
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

Review 8.  Strategies for rapid in vivo 1H and hyperpolarized 13C MR spectroscopic imaging.

Authors:  Sarah J Nelson; Eugene Ozhinsky; Yan Li; Il woo Park; Jason Crane
Journal:  J Magn Reson       Date:  2013-02-08       Impact factor: 2.229

9.  Short-echo three-dimensional H-1 MR spectroscopic imaging of patients with glioma at 7 Tesla for characterization of differences in metabolite levels.

Authors:  Yan Li; Peder Larson; Albert P Chen; Janine M Lupo; Eugene Ozhinsky; Douglas Kelley; Susan M Chang; Sarah J Nelson
Journal:  J Magn Reson Imaging       Date:  2014-06-17       Impact factor: 4.813

10.  Fast 3D rosette spectroscopic imaging of neocortical abnormalities at 3 T: Assessment of spectral quality.

Authors:  Claudiu V Schirda; Tiejun Zhao; Victor E Yushmanov; Yoojin Lee; Gena R Ghearing; Frank S Lieberman; Ashok Panigrahy; Hoby P Hetherington; Jullie W Pan
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.