Literature DB >> 16187045

Reliability of the first eye and second eye in frequency doubling technology perimetry.

Satoshi Mukai1, Hidetoshi Tsukamoto, Aiko Iwase, Hiromu K Mishima.   

Abstract

PURPOSE: To compare the reliability of the perimetry results of the first eye and the second eye with frequency doubling technology (FDT).
METHODS: The subjects were 328 residents who underwent the C-20-5 mode of FDT at a city in central Japan. FDT perimetry was always performed first in the right eye and then in the left eye without any time between tests. When more than 33% fixation loss or false-positive error was detected, the result was judged unreliable.
RESULTS: Of the 328 subjects, the bilateral perimetry results were reliable in 255 subjects (77.7%), the unilateral results were reliable in 57 (17.4%), and there was not a reliable result in either eye in 16 (4.9%) subjects. Of the 57 subjects whose unilateral result was unreliable, the result of the second eye was unreliable in 50 (88%) subjects, and the result of the first eye was unreliable in 7 (12%). This difference in the reliability between the first eye and second eye was significant (P < 0.001). There were no differences in the age, sex, visual acuity, refractive error, test duration, or number of glaucoma suspects between the two groups whose unilateral result was unreliable in the first eye or the second eye.
CONCLUSIONS: The FDT perimetry result of the second eye was less reliable than that of the first eye.

Entities:  

Mesh:

Year:  2005        PMID: 16187045     DOI: 10.1007/s10384-004-0222-4

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  5 in total

1.  Learning effects among perimetric novices in frequency doubling technology perimetry.

Authors:  Peter J Joson; Maria E G Kamantigue; Philip P Chen
Journal:  Ophthalmology       Date:  2002-04       Impact factor: 12.079

2.  Effect of dichoptic adaptation on frequency-doubling perimetry.

Authors:  Andrew John Anderson; Chris A Johnson
Journal:  Optom Vis Sci       Date:  2002-02       Impact factor: 1.973

3.  Laterality of the performance of glaucoma mass screening using frequency-doubling technology.

Authors:  Masayuki Tatemichi; Tadashi Nakano; Katsutoshi Tanaka; Takeshi Hayashi; Takeshi Nawa; Akio Iwasaki; Toshiaki Miyamoto; Hisanori Hiro; Minoru Sugita
Journal:  J Glaucoma       Date:  2003-06       Impact factor: 2.503

4.  Frequency doubling perimetry and the detection of eye disease in the community.

Authors:  G A Cioffi; S Mansberger; P Spry; C Johnson; E M Van Buskirk
Journal:  Trans Am Ophthalmol Soc       Date:  2000

5.  The effect of perimetric experience in patients with glaucoma.

Authors:  A Heijl; B Bengtsson
Journal:  Arch Ophthalmol       Date:  1996-01
  5 in total
  2 in total

1.  Recovery of reliability by retest after a 5-minute interval in frequency doubling technology perimetry.

Authors:  Hidetoshi Tsukamoto; Satoshi Mukai; Aiko Iwase; Hiromu K Mishima
Journal:  Jpn J Ophthalmol       Date:  2006 Jul-Aug       Impact factor: 2.447

Review 2.  [Functional glaucoma diagnosis].

Authors:  C Erb; K Göbel
Journal:  Ophthalmologe       Date:  2009-04       Impact factor: 1.059