Literature DB >> 12782839

Laterality of the performance of glaucoma mass screening using frequency-doubling technology.

Masayuki Tatemichi1, Tadashi Nakano, Katsutoshi Tanaka, Takeshi Hayashi, Takeshi Nawa, Akio Iwasaki, Toshiaki Miyamoto, Hisanori Hiro, Minoru Sugita.   

Abstract

PURPOSE: This study investigated laterality during the performance of glaucoma mass screening with a frequency-doubling technology perimetry test.
MATERIALS AND METHODS: A frequency-doubling technology screening mode (C-20-1, version 2.6) test was performed on both eyes of 14,784 persons. Subjects with visual field abnormalities detected by the frequency-doubling technology test or with fixation error underwent retesting without a specified interval for rest. Consequently, 206 subjects who fulfilled the screening criteria of the frequency-doubling technology-based glaucoma screening protocol [FDT-GSP(+)] were further investigated using the Humphrey visual field analyzer (30-2). As a result, 74 right eyes and 57 left eyes were shown to have definite glaucoma.
RESULTS: Frequency-doubling technology data for the left eye demonstrated a significantly (P<0.001) higher rate of artifacts, such as no reproducibility of results between the first and second tests (left/right: 2.4%/1.7%) as well as fixation errors (left/right: 2.8%/1.0%). The false-positive rate of the FDT-GSP for glaucoma was more than 1.5-fold higher in the left eye than in the right eye (16.3%/9.8%). In the case that either eye exhibited FDT-GSP(+), the positive predictive value of the FDT-GSP for definite glaucoma in the left eye was almost half of that in the right eye (28.4% vs. 53.8%). Specificity of the FDT-GSP for detection of definite glaucoma also exhibited a lower trend (P = 0.097) in the left eye (44.6%) than in the right eye (55.3%), but the sensitivity of the test was similar in both eyes (91.2% vs. 90.5%, respectively).
CONCLUSIONS: When frequency-doubling technology-based mass screening is performed on the general population, performance is lower for the left eye than for the right eye. This performance disparity is likely to be primarily associated with a difference in specificity.

Entities:  

Mesh:

Year:  2003        PMID: 12782839     DOI: 10.1097/00061198-200306000-00007

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  8 in total

1.  Reliability of the first eye and second eye in frequency doubling technology perimetry.

Authors:  Satoshi Mukai; Hidetoshi Tsukamoto; Aiko Iwase; Hiromu K Mishima
Journal:  Jpn J Ophthalmol       Date:  2005 Sep-Oct       Impact factor: 2.447

2.  Recovery of reliability by retest after a 5-minute interval in frequency doubling technology perimetry.

Authors:  Hidetoshi Tsukamoto; Satoshi Mukai; Aiko Iwase; Hiromu K Mishima
Journal:  Jpn J Ophthalmol       Date:  2006 Jul-Aug       Impact factor: 2.447

3.  Risk factors for glaucoma are reflected in abnormal responses to frequency-doubling technology screening in both normal and glaucoma eyes.

Authors:  Aiko Iwase; Tae Tsutsumi; Makoto Fujii; Shoichi Sawaguchi; Makoto Araie
Journal:  Sci Rep       Date:  2022-07-09       Impact factor: 4.996

4.  Line bisection in Parkinson's disease: investigation of contributions of visual field, retinal vision, and scanning patterns to visuospatial function.

Authors:  Thomas M Laudate; Sandy Neargarder; Alice Cronin-Golomb
Journal:  Behav Neurosci       Date:  2013-01-28       Impact factor: 1.912

5.  Possible association between heavy computer users and glaucomatous visual field abnormalities: a cross sectional study in Japanese workers.

Authors:  Masayuki Tatemichi; Tadashi Nakano; Katsutoshi Tanaka; Takeshi Hayashi; Takeshi Nawa; Toshiaki Miyamoto; Hisanori Hiro; Minoru Sugita
Journal:  J Epidemiol Community Health       Date:  2004-12       Impact factor: 3.710

6.  Applicability of automatic spectral domain optical coherence tomography for glaucoma mass screening.

Authors:  Tadashi Nakano; Takeshi Hayashi; Toru Nakagawa; Toru Honda; Satoshi Owada; Hitoshi Endo; Masayuki Tatemichi
Journal:  Clin Ophthalmol       Date:  2016-12-29

7.  Increased Incidence of Visual Field Abnormalities as Determined by Frequency Doubling Technology Perimetry in High Computer Users Among Japanese Workers: A Retrospective Cohort Study.

Authors:  Tadashi Nakano; Takeshi Hayashi; Toru Nakagawa; Toru Honda; Satoshi Owada; Hitoshi Endo; Masayuki Tatemichi
Journal:  J Epidemiol       Date:  2017-11-25       Impact factor: 3.211

8.  Real-Time Risk Score for Glaucoma Mass Screening by Spectral Domain Optical Coherence Tomography: Development and Validation.

Authors:  Kota Fukai; Ryo Terauchi; Takahiko Noro; Shumpei Ogawa; Tomoyuki Watanabe; Toru Nakagawa; Toru Honda; Yuya Watanabe; Yuko Furuya; Takeshi Hayashi; Masayuki Tatemichi; Tadashi Nakano
Journal:  Transl Vis Sci Technol       Date:  2022-08-01       Impact factor: 3.048

  8 in total