Literature DB >> 16183939

CT images of abdomen and pelvis: effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics.

Stefania M R Rizzo1, Mannudeep K Kalra, Bernhard Schmidt, Rainer Raupach, Michael M Maher, Michael A Blake, Sanjay Saini.   

Abstract

The purpose of this study was to retrospectively assess the effect of a postprocessing nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics in abdominal and pelvic computed tomographic (CT) images. Institutional review board approved the HIPAA-compliant study protocol; informed consent was waived. Abdominal and pelvic CT images (40 patients; male-female ratio, 20:20; age range, 28-86 years) at 5-mm (n = 20) and 2-mm (n = 20) section thicknesses were postprocessed with the algorithm at three noise reduction levels. Image noise at the level of porta hepatis and acetabulum was evaluated with a five-point scale (1, no or minimal noise; 5, unacceptable noise), and presence and number of lesions and conspicuity were assessed. Statistical analysis was performed (Wilcoxon signed rank test, analysis of variance). Significant noise reduction was noted at all three levels with the algorithm (P < .05). Reduction in image contrast was noted with only one noise reduction level (P < .0001). The algorithm improves image noise without affecting lesion conspicuity and detection on low-dose abdominal and pelvic CT images. RSNA, 2005

Entities:  

Mesh:

Year:  2005        PMID: 16183939     DOI: 10.1148/radiol.2371041879

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Do DWI and quantitative DCE perfusion MR have a prognostic value in high-grade serous ovarian cancer?

Authors:  Francesca De Piano; Valentina Buscarino; Dulia Maresca; Patrick Maisonneuve; Giovanni Aletti; Roberta Lazzari; Andrea Vavassori; Massimo Bellomi; Stefania Rizzo
Journal:  Radiol Med       Date:  2019-08-31       Impact factor: 3.469

2.  Feasibility of dose reduction using novel denoising techniques for low kV (80 kV) CT enterography: optimization and validation.

Authors:  Luís S Guimarães; Joel G Fletcher; Lifeng Yu; James E Huprich; Jeff L Fidler; Armando Manduca; Juan Carlos Ramirez-Giraldo; David R Holmes; Cynthia H McCollough
Journal:  Acad Radiol       Date:  2010-10       Impact factor: 3.173

3.  Radiation dose reduction with application of non-linear adaptive filters for abdominal CT.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Mi Kim Sung; Anni Back; Michael A Blake
Journal:  World J Radiol       Date:  2012-01-28

4.  A cancer-mimicking diagnosis of peritoneal carcinosis: report of a case of abdominal non-tuberculous mycobacterial infection.

Authors:  Francesca De Piano; Filippo Savoldi; Francesca Ruju; Mariacristina Ghioni; Vanna Zanagnolo; Stefania Rizzo
Journal:  Ecancermedicalscience       Date:  2018-08-21

Review 5.  Radiomics: the facts and the challenges of image analysis.

Authors:  Stefania Rizzo; Francesca Botta; Sara Raimondi; Daniela Origgi; Cristiana Fanciullo; Alessio Giuseppe Morganti; Massimo Bellomi
Journal:  Eur Radiol Exp       Date:  2018-11-14

6.  Incidental diagnosis of pulmonary mycobacteriosis among patients scheduled for lung cancer surgery: results from a series of 3224 consecutive operations.

Authors:  Francesco Petrella; Monica Casiraghi; Elena Prisciandaro; Lorenzo Gherzi; Lorenzo Spaggiari
Journal:  Heliyon       Date:  2019-03-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.