Literature DB >> 16156305

A polymethylpentene fiber gas exchanger for long-term extracorporeal life support.

John M Toomasian1, Robert J Schreiner, David E Meyer, Monica E Schmidt, Sarah E Hagan, Grant W Griffith, Robert H Bartlett, Keith E Cook.   

Abstract

A polymethylpentene (PMP) fiber gas exchange device was evaluated in healthy sheep (35-42 kg) to characterize its performance and potential use in clinical extracorporeal life support (ECLS). Five PMP devices (1.3 m2) were compared with five silicone rubber membrane lung (SRML) devices (1.5 m2) that were supported on venovenous ECLS for 72 hours. The two device groups were compared for differences in gas exchange, device pressure gradient, hematology, blood biochemistry, and pathology. The results showed superiority in the PMP devices in both oxygen and CO2 exchange when compared at similar blood flow rates. Platelet consumption and the device pressure gradient were significantly less when using the PMP device. The device pressure gradient across the PMP devices was < 20 mm Hg as compared with > 150 mm Hg for the SRML devices at all blood flow rates. Changes in plasma hemoglobin levels, leukocyte counts, blood chemistry results, and pathologic findings were not significantly different between the two device groups. Plasma leakage or device failure did not occur in any of the test devices. These data support the use of the PMP device for extended circulatory support. Patients may fare better because of improved preservation of platelets, and the low resistance may allow for wider use of centrifugal-style pumps or the use of the device in a pumpless arteriovenous mode.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16156305     DOI: 10.1097/01.mat.0000169111.66328.a8

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  18 in total

1.  Low-Flow Extracorporeal Carbon Dioxide Removal Using the Hemolung Respiratory Dialysis System® to Facilitate Lung-Protective Mechanical Ventilation in Acute Respiratory Distress Syndrome.

Authors:  Bindu Akkanti; Keshava Rajagopal; Kirti P Patel; Sangeeta Aravind; Emmanuel Nunez-Centanu; Rahat Hussain; Farshad Raissi Shabari; Wayne L Hofstetter; Ara A Vaporciyan; Igor S Banjac; Biswajit Kar; Igor D Gregoric; Pranav Loyalka
Journal:  J Extra Corpor Technol       Date:  2017-06

2.  Triboelectric charging and dissipation characteristics of the Maquet Quadrox-D membrane oxygenator.

Authors:  Melissa S Alberts; Scott D Niles; Dennis Wilson; James Ploessl
Journal:  J Extra Corpor Technol       Date:  2009-06

Review 3.  Emergency cardiac surgery in patients with acute coronary syndromes: a review of the evidence and perioperative implications of medical and mechanical therapeutics.

Authors:  Charles Brown; Brijen Joshi; Nauder Faraday; Ashish Shah; David Yuh; Jeffrey J Rade; Charles W Hogue
Journal:  Anesth Analg       Date:  2011-03-08       Impact factor: 5.108

4.  Development of zwitterionic sulfobetaine block copolymer conjugation strategies for reduced platelet deposition in respiratory assist devices.

Authors:  Alexander D Malkin; Sang-Ho Ye; Evan J Lee; Xiguang Yang; Yang Zhu; Lara J Gamble; William J Federspiel; William R Wagner
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2018-02-09       Impact factor: 3.368

5.  Effects on membrane lung gas exchange of an intermittent high gas flow recruitment maneuver: preliminary data in veno-venous ECMO patients.

Authors:  Luigi Castagna; Alberto Zanella; Vittorio Scaravilli; Federico Magni; Salua Abd El Aziz El Sayed Deab; Michele Introna; Francesco Mojoli; Giacomo Grasselli; Antonio Pesenti; Nicolò Patroniti
Journal:  J Artif Organs       Date:  2015-03-26       Impact factor: 1.731

Review 6.  Extracorporeal carbon dioxide removal (ECCO2R) in respiratory deficiency and current investigations on its improvement: a review.

Authors:  Hany Hazfiza Manap; Ahmad Khairi Abdul Wahab
Journal:  J Artif Organs       Date:  2016-05-18       Impact factor: 1.731

7.  A biohybrid artificial lung prototype with active mixing of endothelialized microporous hollow fibers.

Authors:  Alexa A Polk; Timothy M Maul; Daniel T McKeel; Trevor A Snyder; Craig A Lehocky; Bruce Pitt; Donna Beer Stolz; William J Federspiel; William R Wagner
Journal:  Biotechnol Bioeng       Date:  2010-06-15       Impact factor: 4.530

8.  Rapid-onset plasma leakage of extracorporeal oxygenation membranes possibly due to hyperbilirubinemia.

Authors:  Yoshiko Kida; Shinichiro Ohshimo; Michihito Kyo; Yuko Tanabe; Kei Suzuki; Koji Hosokawa; Nobuaki Shime
Journal:  J Artif Organs       Date:  2018-06-02       Impact factor: 1.731

Review 9.  Bench to bedside review: Extracorporeal carbon dioxide removal, past present and future.

Authors:  Matthew E Cove; Graeme MacLaren; William J Federspiel; John A Kellum
Journal:  Crit Care       Date:  2012-09-21       Impact factor: 9.097

Review 10.  Advances in extracorporeal membrane oxygenator design for artificial placenta technology.

Authors:  David G Blauvelt; Emily N Abada; Peter Oishi; Shuvo Roy
Journal:  Artif Organs       Date:  2020-11-04       Impact factor: 3.094

View more