Literature DB >> 19681309

Triboelectric charging and dissipation characteristics of the Maquet Quadrox-D membrane oxygenator.

Melissa S Alberts1, Scott D Niles, Dennis Wilson, James Ploessl.   

Abstract

Triboelectric charging is commonly detected during cardiopulmonary bypass in circuits using roller pumps and PVC tubing. Dissipation of this charging is needed to prevent a spontaneous discharge from occurring. We evaluated the ability of the Quadrox-D (Maquet) to effectively remove the electrostatic charge accumulation, with and without a heater/cooler connection (H/C). A Quadrox-D oxygenator was evaluated using a Stockert SIII pump head, Cincinnati subzero H/E, and a custom adult extracorporeal membrane oxygenation tubing pack with 1/2" PVC raceway. The circuit was primed and evaluated for triboelectric accumulation with and without H/C use. The results showed a linear relationship between increasing pump flow and static charge buildup when an H/C was not applied. The calculated r2 value was .95. Incorporation of the H/C effectively eliminated charge accumulation. Increasing pump speed increases the amount of static charge created without the use of an H/C. Incorporation of an H/C effectively eliminates charge build-up in the Quadrox-D and is recommended while priming the circuit.

Mesh:

Year:  2009        PMID: 19681309      PMCID: PMC4680203     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  5 in total

1.  A siliconized hollow fiber membrane oxygenator.

Authors:  X M Mueller; B Marty; H T Tevaearai; P Tozzi; D Jegger; L K von Segesser
Journal:  ASAIO J       Date:  2000 Jan-Feb       Impact factor: 2.872

2.  ECG noise on cardiopulmonary bypass.

Authors:  A Wald; J G Stone; H J Khambatta; L B Mongero
Journal:  Med Biol Eng Comput       Date:  1990-07       Impact factor: 2.602

3.  A polymethylpentene fiber gas exchanger for long-term extracorporeal life support.

Authors:  John M Toomasian; Robert J Schreiner; David E Meyer; Monica E Schmidt; Sarah E Hagan; Grant W Griffith; Robert H Bartlett; Keith E Cook
Journal:  ASAIO J       Date:  2005 Jul-Aug       Impact factor: 2.872

4.  Study on causes and prevention of electrostatic charge build-up during extracorporeal circulation.

Authors:  J Snijders; P de Bruijn; M Bergmans; G Bastianen
Journal:  Perfusion       Date:  1999-09       Impact factor: 1.972

5.  Investigation of the phenomenon of electrostatic compromise of a plastic fiber heat exchanger.

Authors:  R J Elgas
Journal:  Perfusion       Date:  1999-03       Impact factor: 1.972

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.