Literature DB >> 20091735

A biohybrid artificial lung prototype with active mixing of endothelialized microporous hollow fibers.

Alexa A Polk1, Timothy M Maul, Daniel T McKeel, Trevor A Snyder, Craig A Lehocky, Bruce Pitt, Donna Beer Stolz, William J Federspiel, William R Wagner.   

Abstract

Acute respiratory distress syndrome (ARDS) affects nearly 150,000 patients per year in the US, and is associated with high mortality ( approximately 40%) and suboptimal options for patient care. Mechanical ventilation and extracorporeal membrane oxygenation are limited to short-term use due to ventilator-induced lung injury and poor biocompatibility, respectively. In this report, we describe the development of a biohybrid lung prototype, employing a rotating endothelialized microporous hollow fiber (MHF) bundle to improve blood biocompatibility while MHF mixing could contribute to gas transfer efficiency. MHFs were surface modified with radio frequency glow discharge (RFGD) and protein adsorption to promote endothelial cell (EC) attachment and growth. The MHF bundles were placed in the biohybrid lung prototype and rotated up to 1,500 revolutions per minute (rpm) using speed ramping protocols to condition ECs to remain adherent on the fibers. Oxygen transfer, thrombotic deposition, and EC p-selectin expression were evaluated as indicators of biohybrid lung functionality and biocompatibility. A fixed aliquot of blood in contact with MHF bundles rotated at either 250 or 750 rpm reached saturating pO(2) levels more quickly with increased rpm, supporting the concept that fiber rotation would positively contribute to oxygen transfer. The presence of ECs had no effect on the rate of oxygen transfer at lower fiber rpm, but did provide some resistance with increased rpm when the overall rate of mass transfer was higher due to active mixing. RFGD followed by fibronectin adsorption on MHFs facilitated near confluent EC coverage with minimal p-selectin expression under both normoxic and hyperoxic conditions. Indeed, even subconfluent EC coverage on MHFs significantly reduced thrombotic deposition adding further support that endothelialization enhances, blood biocompatibility. Overall these findings demonstrate a proof-of-concept that a rotating endothelialized MHF bundle enhances gas transfer and biocompatibility, potentially producing safer, more efficient artificial lungs. 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20091735      PMCID: PMC4136649          DOI: 10.1002/bit.22675

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  59 in total

1.  Computational fluid flow and mass transfer of a functionally integrated pediatric pump-oxygenator configuration.

Authors:  Brian Fill; Mark Gartner; Greg Johnson; Marc Horner; Jeff Ma
Journal:  ASAIO J       Date:  2008 Mar-Apr       Impact factor: 2.872

2.  Application of elastic salmon collagen gel to uniaxial stretching culture of human umbilical vein endothelial cells.

Authors:  Toshiyuki Kanayama; Nobuhiro Nagai; Kazuo Mori; Masanobu Munekata
Journal:  J Biosci Bioeng       Date:  2008-05       Impact factor: 2.894

3.  Frequency and mortality of acute lung injury and acute respiratory distress syndrome after pulmonary resection for bronchogenic carcinoma.

Authors:  E Ruffini; A Parola; E Papalia; P L Filosso; M Mancuso; A Oliaro; G Actis-Dato; G Maggi
Journal:  Eur J Cardiothorac Surg       Date:  2001-07       Impact factor: 4.191

4.  Molecular mechanism of endothelial growth arrest by laminar shear stress.

Authors:  K Lin; P P Hsu; B P Chen; S Yuan; S Usami; J Y Shyy; Y S Li; S Chien
Journal:  Proc Natl Acad Sci U S A       Date:  2000-08-15       Impact factor: 11.205

5.  Effect of biologically active coating on biocompatibility of Nitinol devices designed for the closure of intra-atrial communications.

Authors:  Xiangqing Kong; R G Grabitz; W van Oeveren; D Klee; T G van Kooten; F Freudenthal; Ma Qing; G von Bernuth; M C Seghaye
Journal:  Biomaterials       Date:  2002-04       Impact factor: 12.479

6.  Estimate of gas transfer rates of an intravascular membrane oxygenator.

Authors:  T Kanamori; M Niwa; H Kawakami; Y Mori; S Nagaoka; K Haraya; T Shinbo
Journal:  ASAIO J       Date:  2000 Sep-Oct       Impact factor: 2.872

Review 7.  Artificial lungs: a new inspiration.

Authors:  Joseph B Zwischenberger; Scott K Alpard
Journal:  Perfusion       Date:  2002-07       Impact factor: 1.972

8.  Membrane fluidity and oxygen diffusion in cholesterol-enriched endothelial cells.

Authors:  D Dumas; V Latger; M L Viriot; W Blondel; J F Stoltz
Journal:  Clin Hemorheol Microcirc       Date:  1999       Impact factor: 2.375

Review 9.  Corticosteroids in the prevention and treatment of acute respiratory distress syndrome (ARDS) in adults: meta-analysis.

Authors:  John Victor Peter; Preeta John; Petra L Graham; John L Moran; Ige Abraham George; Andrew Bersten
Journal:  BMJ       Date:  2008-04-23

10.  A new concept of integrated cardiopulmonary bypass circuit.

Authors:  Xavier M Mueller; David Jegger; Monique Augstburger; Judith Horisberger; Gilles Godar; Ludwig K von Segesser
Journal:  Eur J Cardiothorac Surg       Date:  2002-05       Impact factor: 4.191

View more
  9 in total

Review 1.  Artificial lung.

Authors:  Francesco Petrella; Lorenzo Spaggiari
Journal:  J Thorac Dis       Date:  2018-07       Impact factor: 2.895

2.  Modular microfluidic system as a model of cystic fibrosis airways.

Authors:  M Skolimowski; M Weiss Nielsen; F Abeille; P Skafte-Pedersen; D Sabourin; A Fercher; D Papkovsky; S Molin; R Taboryski; C Sternberg; M Dufva; O Geschke; J Emnéus
Journal:  Biomicrofluidics       Date:  2012-08-02       Impact factor: 2.800

3.  ENDOXY - Development of a Biomimetic Oxygenator-Test-Device.

Authors:  Maren Dietrich; Nicole Finocchiaro; Sebastian Olszweski; Jutta Arens; Thomas Schmitz-Rode; Joerg Sachweh; Stefan Jockenhoevel; Christian G Cornelissen
Journal:  PLoS One       Date:  2015-12-18       Impact factor: 3.240

4.  Towards a Biohybrid Lung: Endothelial Cells Promote Oxygen Transfer through Gas Permeable Membranes.

Authors:  Sarah Menzel; Nicole Finocchiaro; Christine Donay; Anja Lena Thiebes; Felix Hesselmann; Jutta Arens; Suzana Djeljadini; Matthias Wessling; Thomas Schmitz-Rode; Stefan Jockenhoevel; Christian Gabriel Cornelissen
Journal:  Biomed Res Int       Date:  2017-08-23       Impact factor: 3.411

Review 5.  Bioengineering of Pulmonary Epithelium With Preservation of the Vascular Niche.

Authors:  N Valerio Dorrello; Gordana Vunjak-Novakovic
Journal:  Front Bioeng Biotechnol       Date:  2020-04-15

Review 6.  Advances in extracorporeal membrane oxygenator design for artificial placenta technology.

Authors:  David G Blauvelt; Emily N Abada; Peter Oishi; Shuvo Roy
Journal:  Artif Organs       Date:  2020-11-04       Impact factor: 3.094

7.  EndOxy: Dynamic Long-Term Evaluation of Endothelialized Gas Exchange Membranes for a Biohybrid Lung.

Authors:  Sarah Klein; Felix Hesselmann; Suzana Djeljadini; Tanja Berger; Anja Lena Thiebes; Thomas Schmitz-Rode; Stefan Jockenhoevel; Christian G Cornelissen
Journal:  Ann Biomed Eng       Date:  2019-11-21       Impact factor: 3.934

Review 8.  The Roles of Membrane Technology in Artificial Organs: Current Challenges and Perspectives.

Authors:  Bao Tran Duy Nguyen; Hai Yen Nguyen Thi; Bich Phuong Nguyen Thi; Dong-Ku Kang; Jeong F Kim
Journal:  Membranes (Basel)       Date:  2021-03-28

Review 9.  Toward a Long-Term Artificial Lung.

Authors:  Jutta Arens; Oliver Grottke; Axel Haverich; Lars S Maier; Thomas Schmitz-Rode; Ulrich Steinseifer; H P Wendel; Rolf Rossaint
Journal:  ASAIO J       Date:  2020-08       Impact factor: 3.826

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.