Literature DB >> 16149060

4D radial coronary artery imaging within a single breath-hold: cine angiography with phase-sensitive fat suppression (CAPS).

Jaeseok Park1, Andrew C Larson, Qiang Zhang, Orlando Simonetti, Debiao Li.   

Abstract

Coronary artery data acquisition with steady-state free precession (SSFP) is typically performed in a single frame in mid-diastole with a spectrally selective pulse to suppress epicardial fat signal. Data are acquired while the signal approaches steady state, which may lead to artifacts from the SSFP transient response. To avoid sensitivity to cardiac motion, an accurate trigger delay and data acquisition window must be determined. Cine data acquisition is an alternative approach for resolving these limitations. However, it is challenging to use conventional fat saturation with cine imaging because it interrupts the steady-state condition. The purpose of this study was to develop a 4D coronary artery imaging technique, termed "cine angiography with phase-sensitive fat suppression" (CAPS), that would result in high temporal and spatial resolution simultaneously. A 3D radial stacked k-space was acquired over the entire cardiac cycle and then interleaved with a sliding window. Sensitivity-encoded (SENSE) reconstruction with rescaling was developed to reduce streak artifact and noise. Phase-sensitive SSFP was employed for fat suppression using phase detection. Experimental studies were performed on volunteers. The proposed technique provides high-resolution coronary artery imaging for all cardiac phases, and allows multiple images at mid-diastole to be averaged, thus enhancing the signal-to-noise ratio (SNR) and vessel delineation. Copyright 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16149060     DOI: 10.1002/mrm.20627

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Fast four-dimensional coronary MR angiography with k-t GRAPPA.

Authors:  Peng Lai; Feng Huang; Andrew C Larson; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2008-03       Impact factor: 4.813

2.  Respiratory self-gated four-dimensional coronary MR angiography: a feasibility study.

Authors:  Peng Lai; Andrew C Larson; Jaeseok Park; James C Carr; Debiao Li
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

Review 3.  The promise of whole-heart coronary MRI.

Authors:  Thomas H Hauser; Warren J Manning
Journal:  Curr Cardiol Rep       Date:  2008-02       Impact factor: 2.931

Review 4.  Cardiac Magnetic Resonance Quantification of Structure-Function Relationships in Heart Failure.

Authors:  Kim-Lien Nguyen; Peng Hu; J Paul Finn
Journal:  Heart Fail Clin       Date:  2020-10-28       Impact factor: 3.179

5.  5D whole-heart sparse MRI.

Authors:  Li Feng; Simone Coppo; Davide Piccini; Jerome Yerly; Ruth P Lim; Pier Giorgio Masci; Matthias Stuber; Daniel K Sodickson; Ricardo Otazo
Journal:  Magn Reson Med       Date:  2017-05-11       Impact factor: 4.668

6.  Three-dimensional morphological magnetic resonance imaging in infants and children with congenital heart disease.

Authors:  Michael Fenchel; Gerald F Greil; Petros Martirosian; Ulrich Kramer; Fritz Schick; Claus D Claussen; Ludger Sieverding; Stephan Miller
Journal:  Pediatr Radiol       Date:  2006-09-28

Review 7.  Cardiac MR: From Theory to Practice.

Authors:  Tevfik F Ismail; Wendy Strugnell; Chiara Coletti; Maša Božić-Iven; Sebastian Weingärtner; Kerstin Hammernik; Teresa Correia; Thomas Küstner
Journal:  Front Cardiovasc Med       Date:  2022-03-03

8.  3.0T whole-heart coronary magnetic resonance angiography performed with 32-channel cardiac coils: a single-center experience.

Authors:  Qi Yang; Kuncheng Li; Xin Liu; Xiangying Du; Xiaoming Bi; Feng Huang; Renate Jerecic; Zhi Liu; Jing An; Dong Xu; Hairong Zheng; Zhaoyang Fan; Debiao Li
Journal:  Circ Cardiovasc Imaging       Date:  2012-08-10       Impact factor: 7.792

9.  ECG and navigator-free four-dimensional whole-heart coronary MRA for simultaneous visualization of cardiac anatomy and function.

Authors:  Jianing Pang; Behzad Sharif; Zhaoyang Fan; Xiaoming Bi; Reza Arsanjani; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-09-12       Impact factor: 4.668

10.  Volumetric coronary endothelial function assessment: a feasibility study exploiting stack-of-stars 3D cine MRI and image-based respiratory self-gating.

Authors:  Gabriele Bonanno; Robert G Weiss; Davide Piccini; Jérôme Yerly; Sahar Soleimani; Li Pan; Xiaoming Bi; Allison G Hays; Matthias Stuber; Michael Schär
Journal:  NMR Biomed       Date:  2021-07-21       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.