Literature DB >> 16148397

Simulation of organ-specific patient effective dose due to secondary neutrons in proton radiation treatment.

Hongyu Jiang1, Brian Wang, X George Xu, Herman D Suit, Harald Paganetti.   

Abstract

Cancer patients undergoing radiation treatment are exposed to high doses to the target (tumour), intermediate doses to adjacent tissues and low doses from scattered radiation to all parts of the body. In the case of proton therapy, secondary neutrons generated in the accelerator head and inside the patient reach many areas in the patient body. Due to the improved efficacy of management of cancer patients, the number of long term survivors post-radiation treatment is increasing substantially. This results in concern about the risk of radiation-induced cancer appearing at late post-treatment times. This paper presents a case study to determine the effective dose from secondary neutrons in patients undergoing proton treatment. A whole-body patient model, VIP-Man, was employed as the patient model. The geometry dataset generated from studies made on VIP-Man was implemented into the GEANT4 Monte Carlo code. Two proton treatment plans for tumours in the lung and paranasal sinus were simulated. The organ doses and ICRP-60 radiation and tissue weighting factors were used to calculate the effective dose. Results show whole body effective doses for the two proton plans of 0.162 Sv and 0.0266 Sv, respectively, to which the major contributor is due to neutrons from the proton treatment nozzle. There is a substantial difference among organs depending on the treatment site.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16148397     DOI: 10.1088/0031-9155/50/18/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  28 in total

1.  Dosimetric evaluation of nuclear interaction models in the Geant4 Monte Carlo simulation toolkit for carbon-ion radiotherapy.

Authors:  S Kameoka; K Amako; G Iwai; K Murakami; T Sasaki; T Toshito; T Yamashita; T Aso; A Kimura; T Kanai; N Kanematsu; M Komori; Y Takei; S Yonai; M Tashiro; H Koikegami; H Tomita; T Koi
Journal:  Radiol Phys Technol       Date:  2008-07-01

2.  Assessment of out-of-field absorbed dose and equivalent dose in proton fields.

Authors:  Ben Clasie; Andrew Wroe; Hanne Kooy; Nicolas Depauw; Jay Flanz; Harald Paganetti; Anatoly Rosenfeld
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

3.  Monte Carlo and analytical model predictions of leakage neutron exposures from passively scattered proton therapy.

Authors:  Angélica Pérez-Andújar; Rui Zhang; Wayne Newhauser
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

4.  Evaluation of energy deposition and secondary particle production in proton therapy of brain using a slab head phantom.

Authors:  Sayyed Bijan Jia; Mohammad Hadi Hadizadeh; Ali Asghar Mowlavi; Mahdy Ebrahimi Loushab
Journal:  Rep Pract Oncol Radiother       Date:  2014-05-01

Review 5.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

Review 6.  Assessment of the risk for developing a second malignancy from scattered and secondary radiation in radiation therapy.

Authors:  Harald Paganetti
Journal:  Health Phys       Date:  2012-11       Impact factor: 1.316

7.  Comparison of risk of radiogenic second cancer following photon and proton craniospinal irradiation for a pediatric medulloblastoma patient.

Authors:  Rui Zhang; Rebecca M Howell; Annelise Giebeler; Phillip J Taddei; Anita Mahajan; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2013-01-16       Impact factor: 3.609

8.  Reduction of the secondary neutron dose in passively scattered proton radiotherapy, using an optimized pre-collimator/collimator.

Authors:  David J Brenner; Carl D Elliston; Eric J Hall; Harald Paganetti
Journal:  Phys Med Biol       Date:  2009-09-24       Impact factor: 3.609

9.  Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault.

Authors:  Yuanshui Zheng; Wayne Newhauser; Eric Klein; Daniel Low
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

Review 10.  Is there a place for quantitative risk assessment?

Authors:  Eric J Hall
Journal:  J Radiol Prot       Date:  2009-05-19       Impact factor: 1.394

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.