Literature DB >> 16142808

Incidence, retrieval methods, and outcomes of stent loss during percutaneous coronary intervention: a large single-center experience.

Emmanouil S Brilakis1, Patricia J M Best, Ahmad A Elesber, Gregory W Barsness, Ryan J Lennon, David R Holmes, Charanjit S Rihal, Kirk N Garratt.   

Abstract

Our goal was to examine the incidence and consequences of stent loss during percutaneous coronary intervention (PCI) and the retrieval techniques used. We retrospectively reviewed 11,773 consecutive PCI cases involving stents performed at our institution between January 1994 and March 2004 to identify cases of stent loss. Stent loss occurred in 38 of 11,773 PCI procedures involving stents (0.32%; 95% CI = 0.23-0.44%). Mean age of the patients was 67 +/- 11 years and 82% were men. Stent loss occurred more frequently in lesions with calcification and/or significant proximal angulation. In three patients, the stent was crushed and covered with another stent without attempting retrieval. Stent retrieval was attempted in 35 of 38 cases and was successful in 30 (86%). The following retrieval methods were used (more than one method was used in some cases): advancing a balloon through the stent, inflating the balloon, and withdrawing the stent (45%); twirling two wires around the stent (5%); loop snare (26%); biliary forceps (12%); Cook retained fragment retriever (10%); and basket retrieval device (2%). Patients in whom stent loss occurred had a higher incidence of bleeding requiring transfusion (24% vs. 7%; P < 0.001) and more often required emergency coronary artery bypass surgery (5% vs. 0.4%; P < 0.001). No patients in whom the stent was crushed or deployed in the coronary artery had any major cardiac complication. Stent loss during PCI occurs infrequently. Lost stents can be successfully retrieved in the majority of cases using a variety of retrieval techniques, yet stent loss is associated with an increased risk of complications. Stent deployment or crushing may be a good alternative to retrieval. Copyright 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16142808     DOI: 10.1002/ccd.20449

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  37 in total

1.  Successful retrieval of a coronary stent dislodged in the brachial artery by means of improvised snare and guiding catheter.

Authors:  Spyridon Deftereos; Konstantinos Raisakis; Georgios Giannopoulos; Charalampos Kossyvakis; Loukas Pappas; Andreas Kaoukis
Journal:  Int J Angiol       Date:  2011-03

2.  Retrieving a deformed stent during transradial intervention: an alternative femoral approach using guide catheter shortening.

Authors:  Vijay K Trehan; Gagan Jain; Sanjeev Kathuria; Bhagya N Pandit
Journal:  Indian Heart J       Date:  2013-04-09

3.  Endovascular retrieval of a prematurely deployed covered stent.

Authors:  Jefferson T Miley; Gustavo J Rodriguez; Ramachandra P Tummala
Journal:  World J Radiol       Date:  2015-06-28

4.  Coronary artery stent dislodgement and aortic dissection in a patient with a severely calcified lesion in the proximal right coronary artery.

Authors:  Koutaro Kagiyama; Toshifumi Shimada; Masaharu Nakano; Kenta Toyomasu; Kazunori Yamaji; Yuji Aoki; Takafumi Ueno; Yoshihiro Fukumoto
Journal:  J Cardiol Cases       Date:  2017-07-27

5.  Dislodged and mechanically distorted stent stuck within a previously implanted drug-eluting stent.

Authors:  Hiroaki Watabe; Akira Sato; Tomoya Hoshi; Kenichi Obara; Ryo Kawamura; Kazutaka Aonuma
Journal:  Heart Vessels       Date:  2012-09-20       Impact factor: 2.037

6.  Balloon-assisted retrieval of a broken stent-delivery system.

Authors:  Jayashree Kharge; Praveen Sreekumar; Kumara Swamy; Ashalatha Bharatha; Raghu Thagachagere Ramegowda; Manjunath Cholenahally Nanjappa
Journal:  Tex Heart Inst J       Date:  2012

7.  Finding a lost coronary stent months later with use of multimethod imaging.

Authors:  Andrew N Rassi; Gus Theodos; Irving Franco
Journal:  Tex Heart Inst J       Date:  2014-08-01

8.  A Novel Approach for the Retrieval of Broken Catheter Fragment - Using Balloon Dilatation Technique.

Authors:  Padmakumar Ramachandran; Rohith Poondru Reddy; M Sudhakar Rao; Ashwal Adamane Jayaram
Journal:  J Clin Diagn Res       Date:  2016-03-01

9.  Successful coronary stent retrieval from the saphenous vein graft to right coronary artery.

Authors:  Mustafa Aydin; Muhammet Rasit Sayin
Journal:  Case Rep Med       Date:  2009-11-08

10.  A novel technique for retrieval of a drug-eluting stent after catheter break and stent loss.

Authors:  Sunil P Wani; Seung-Woon Rha; Ji Young Park; Kanhaiya L Poddar; Lin Wang; Sureshkumar Ramasamy; Ji Mi Moon; Ji Bak Kim; Sang Ryol Ryu; Seung Yong Shin; Un-Jung Choi; Cheol Ung Choi; Hong Euy Lim; Jin Won Kim; Eung Ju Kim; Chang Gyu Park; Hong Seog Seo; Dong Joo Oh
Journal:  Korean Circ J       Date:  2010-08-31       Impact factor: 3.243

View more