Determining the MTF of medical imaging displays using edge techniques.

Amarpreet S Chawla1, Hans Roehrig, Jeffrey J Rodriguez, Jiahua Fan.   

Abstract

The modulation transfer function (MTF) of a medical imaging display is typically determined by measuring its response to square waves (bar patterns), white noise, and/or line stimuli. However, square waves and white noise methods involve capture and analysis of multiple images and are thus quite tedious. Measurement of the line-spread function (LSF) offers a good alternative. However, as previously reported, low-frequency response obtained from the LSF method is not as good as that obtained from measurement of edge-spread function (ESF). In this paper, we present two methods for evaluating the MTF of a medical imaging display from its ESF. High degree of accuracy in the higher frequency region (near the Nyquist frequency of the system) was achieved by reducing the noise. In the first method, which is a variant of the Gans' original method, the periodic raster noise is reduced by subtracting a shifted ESF from the ESF. The second method employs a low-pass differentiator (LPD). A novel near maximally flat LPD with the desired cut-off frequency was designed for this purpose. Noise reduction in both the methods was also achieved by averaging over large portions of the image data to form the ESF. Experimental results show that the MTF obtained by these methods is comparable to that obtained from the square wave response. Furthermore, the MTFs of rising and falling edges of a cathode ray tube (CRT) were measured. The results show that the rising and falling vertical MTFs are practically the same, whereas the rising horizontal MTF is poorer than the falling horizontal MTF in the midfrequency region.

Entities:  

Mesh:

Year:  2005        PMID: 16132485      PMCID: PMC3046730          DOI: 10.1007/s10278-005-6977-4

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  4 in total

1.  Characterization of monochrome CRT display systems in the field.

Authors:  H Roehrig; C E Willis; M A Damento
Journal:  J Digit Imaging       Date:  1999-11       Impact factor: 4.056

2.  Signal and noise in modulation transfer function determinations using the slit, wire, and edge techniques.

Authors:  I A Cunningham; B K Reid
Journal:  Med Phys       Date:  1992 Jul-Aug       Impact factor: 4.071

3.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

4.  An analytical edge spread function model for computer fitting and subsequent calculation of the LSF and MTF.

Authors:  J M Boone; J A Seibert
Journal:  Med Phys       Date:  1994-10       Impact factor: 4.071

  4 in total
  1 in total

1.  Simple computation of the approximated modulation transfer function (MTF) using spreadsheet-software: method and evaluation in five maxillofacial CBCT-devices.

Authors:  Ralf Kurt Willy Schulze; Clara I Doering
Journal:  Dentomaxillofac Radiol       Date:  2019-02-28       Impact factor: 2.419

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.