An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps.

Tugberk Arda1, Ayla Arikan.   

Abstract

STATEMENT OF PROBLEM: The use of metal clasps on anterior teeth may cause esthetic problems. Recently, acetal resins have been used as an alternative tooth-colored denture clasp material to improve esthetics. However, there are few studies to support acetal resin use.
PURPOSE: The purpose of this in vitro study was to compare the retentive force and deformation of acetal resin and cobalt-chromium clasps after 36 months of simulated clinical use.
MATERIAL AND METHODS: Forty clasps each of acetal resin (1.2 or 2.0 mm thick) and cobalt-chromium (Dentorium)(1.2 mm thick) were fabricated using half-round standard prefabricated clasp patterns. The groups were further subdivided (n=10) into the type of tooth (premolar or molar metal model) and undercut (0.25 mm or 0.50 mm). The retentive force of the clasps was measured in distilled water by a specially designed insertion-removal testing apparatus with intervals corresponding to 0, 6, 12, 18, 24, 30, and 36 months of simulated clinical use of a removable partial denture. The distance between the clasp tips (mm) was measured with a microscope before and after the insertion-removal testing procedure. Comparison of the mean values of the retentive force (gram force) of the clasps and the distance (mm) between the clasp tips was conducted with 3-way analysis of variance and a Least Significant Difference (LSD) multiple range test (alpha=.05).
RESULTS: The mean values of tensile load required to dislodge acetal resin clasps with 1.2-mm thickness (111.6 g or 0.11 N) and with 2.0-mm thickness (178.4 g or 1.75 N) was significantly lower than that to dislodge Co-Cr clasps (694.1 g or 6.81 N) (P<.001). The retentive force needed to dislodge all 3 types of clasps was significantly lower for the molar than premolar models and also lower for the models with 0.25-mm undercuts than for those with 0.50-mm undercuts (P<.001). After 36 months of simulated clinical use, there was evidence of deformation in the cobalt-chromium clasps but no deformation noted for the acetal resin clasps. The retentive force of cobalt-chromium clasps (297.4 g or 2.91 N) after deformation remained significantly higher (P<.001) than the retentive force of acetal resin clasps that were 1.2 mm (110.7 g or 1.08 N) and 2.0 mm thick (177.5 g or 1.74 N), respectively.
CONCLUSION: Within the limitations of this study, the results suggest that both thicknesses of acetal resin clasps evaluated required less force for insertion and removal than Co-Cr clasps over a simulated 36-month period.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16126079     DOI: 10.1016/j.prosdent.2005.06.009

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  11 in total

1.  Comparison of Retention of Clasps Made of Different Materials Using Three-Dimensional Finite Element Analysis.

Authors:  Jaggari Chandrakanth Reddy; Sarath Babu Chintapatla; Naveen Kumar Srikakula; Rajesh Kumar Reddy Juturu; Shameen Kumar Paidi; Satyendra Kumar Tedlapu; Padmakanth Mannava; Rukhaiya Khatoon
Journal:  J Clin Diagn Res       Date:  2016-05-01

2.  An Evaluation of Retentive Ability and Deformation of Acetal Resin and Cobalt-Chromium Clasps.

Authors:  A Meenakshi; Ranjana Gupta; Vinay Bharti; G Sriramaprabu; Ramachandra Prabhakar
Journal:  J Clin Diagn Res       Date:  2016-01-01

3.  Guidelines for the choice of circumferential wrought wire and cast clasp arms for removable partial dentures.

Authors:  C Peter Owen; Noland Naidoo
Journal:  Int Dent J       Date:  2021-02-20       Impact factor: 2.607

4.  The effect of environment (Dry and Natural Saliva) on clasp retention: In vitro study - Part I.

Authors:  Bilal Mourshed; Nashwan Mohammed Qaed; Hashem Motahir Al-Shamiri; Nader Alaizari; Saleh Sulaiman Alhamdah; Amal Alfaqih
Journal:  Eur J Dent       Date:  2017 Jul-Sep

5.  Different Materials Used as Denture Retainers and Their Colour Stability.

Authors:  Sherif A Sadek; Wessam M Dehis; Hala Hassan
Journal:  Open Access Maced J Med Sci       Date:  2018-11-15

6.  Comparative Study Clarifying the Most Suitable Material to Be Used as Partial Denture Clasps.

Authors:  Sherif Aly Sadek; Wessam Mohamed Dehis; Hala Hassan
Journal:  Open Access Maced J Med Sci       Date:  2018-06-07

7.  Retention force of polyetheretherketone and cobalt-chrome-molybdenum removable dental prosthesis clasps after artificial aging.

Authors:  Felicitas Mayinger; Danka Micovic; Andreas Schleich; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2020-10-16       Impact factor: 3.573

8.  Effect of clasp type and pullout location on clasp retention in different environment: In vitro study.

Authors:  Bilal Mourshed; Fuad Abdo Al-Sabri; Nashwan Ahmed Qaed; Nader Alaizari; Hashem Motahir Al-Shamiri; Amal Alfaqih
Journal:  Eur J Dent       Date:  2017 Apr-Jun

9.  Examination of inter-rater and intra-rater reliability during retentive force measurement of different clasps using the developed small-sized retentive force measurement device.

Authors:  Hitoshi Akiyama; Maiko Sakamoto; Ryoichi Akama; Jun Takei
Journal:  BMC Oral Health       Date:  2020-08-20       Impact factor: 2.757

10.  Is the high-performance thermoplastic polyetheretherketone indicated as a clasp material for removable dental prostheses?

Authors:  Danka Micovic; Felicitas Mayinger; Sebastian Bauer; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2020-10-07       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.