Literature DB >> 26894173

An Evaluation of Retentive Ability and Deformation of Acetal Resin and Cobalt-Chromium Clasps.

A Meenakshi1, Ranjana Gupta2, Vinay Bharti3, G Sriramaprabu4, Ramachandra Prabhakar5.   

Abstract

AIM: To compare the retentive ability and deformation of Acetal resin with Cobalt-Chromium clasps via Insertion Removal apparatus after subjecting them to stimulate clinical use.
MATERIALS AND METHODS: Materials used for this study are commercially available Cobalt-Chromium alloy namely Wironit, Bego, Germany and Acetal resin namely Biodentaplast, Bredent, Germany. The test samples were divided into two major groups based on the type of materials used in the study. Each major group is further subdivided into two sub groups based on the retentive undercut depths used to engage the clasps. So a total of 20 specimens were prepared, comprising of 5 specimens in each sub group. Then the specimens were tested for retention force and deformation.
RESULTS: The results of this study indicate that acetal resin clasps are resistant to deformation and may offer a clinical advantage over the conventional metal clasps. The retentive force of acetal resin clasps did not decrease over the cycling periods. This would be attributed to the resilient nature of acetal resin. Under the conditions of the present study cobalt chromium clasps lost retentive force within 730 cycles of placement and removal and continued to lose retentive force during the remaining test period.
CONCLUSION: This invitro study demonstrated that retentive force of cobalt chromium clasp is superior to that of Acetal resin for removable partial dentures. As acetal resin clasps exhibits greater flexibility and long term retentive resiliency, it can be used for removable partial dentures where aesthetics or periodontal health is a primary concern.

Entities:  

Keywords:  Aesthetics; Direct retention; Insertion removal apparatus; Removable prostheses

Year:  2016        PMID: 26894173      PMCID: PMC4740701          DOI: 10.7860/JCDR/2016/15476.7078

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  20 in total

1.  The use of chairside silica coating for different dental applications: a clinical report.

Authors:  Mutlu Ozcan
Journal:  J Prosthet Dent       Date:  2002-05       Impact factor: 3.426

2.  The physical properties of a polyacetal denture resin.

Authors:  J S Fitton; E H Davies; J A Howlett; G J Pearson
Journal:  Clin Mater       Date:  1994

3.  The equipoise removable restoration.

Authors:  J J Goodman
Journal:  Trends Tech Contemp Dent Lab       Date:  1991-06

4.  Inconspicuous retention for removable partial dentures.

Authors:  G E King; M T Barco; R J Olson
Journal:  J Prosthet Dent       Date:  1978-05       Impact factor: 3.426

5.  Camouflaging partial denture clasps.

Authors:  M Moreno de Delgado; L T Garcia; K D Rudd
Journal:  J Prosthet Dent       Date:  1986-05       Impact factor: 3.426

6.  Force transmission and retentive capabilities utilizing labial and palatal I-bar partial dentures.

Authors:  R Highton; A Caputo; J Matyas
Journal:  J Oral Rehabil       Date:  1987-09       Impact factor: 3.837

7.  Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp.

Authors:  P K Vallittu; M Kokkonen
Journal:  J Prosthet Dent       Date:  1995-10       Impact factor: 3.426

8.  Stress distribution within circumferential clasp arms.

Authors:  H Morris; J W Farah; R G Craig; J A Hood
Journal:  J Oral Rehabil       Date:  1976-10       Impact factor: 3.837

9.  [Prostheses of thermoplastic materials. Jet casting with a cartridge system].

Authors:  K Wirz
Journal:  Dent Labor (Munch)       Date:  1983-09

10.  In vitro deformation of acetyl resin and metal alloy removable partial denture direct retainers.

Authors:  Jean C Wu; George H Latta; Russell A Wicks; Robert L Swords; Mark Scarbecz
Journal:  J Prosthet Dent       Date:  2003-12       Impact factor: 3.426

View more
  3 in total

1.  Comparison between Integrated and Parallel Interlock Designs of an Extracoronal Attachment-retained Distal Extension Removable Partial Dentures: A Clinical Trial.

Authors:  Maria R Reslan; Essam Osman; Lucette Segaan; Mohammad Rayyan; Christelle Joukhadar; Mohamed Fattouh
Journal:  J Int Soc Prev Community Dent       Date:  2021-01-30

2.  Examination of inter-rater and intra-rater reliability during retentive force measurement of different clasps using the developed small-sized retentive force measurement device.

Authors:  Hitoshi Akiyama; Maiko Sakamoto; Ryoichi Akama; Jun Takei
Journal:  BMC Oral Health       Date:  2020-08-20       Impact factor: 2.757

3.  Teaching the Design and Fabrication of RPD Frameworks With a Digital Workflow: A Preclinical Dental Exercise.

Authors:  Ahmed Mahrous; Tarek El-Kerdani
Journal:  MedEdPORTAL       Date:  2020-10-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.