Literature DB >> 16124971

Influence of cement viscosity and cement mantle thickness on migration of the Exeter total hip prosthesis.

Rob G H H Nelissen1, Eric H Garling, Edward R Valstar.   

Abstract

The effect of bone cement viscosity and cement mantle thickness on the migration of the Exeter total hip prosthesis was studied in a prospective, randomized, double-blind clinical Roentgen Stereophotogrammetric Analysis study. Forty-one cemented total hip arthroplasty in 39 patients were included and randomized into a low/medium Simplex P cement group and a high-viscosity Simplex AF cement group. At time of stem introduction, 5 minutes after mixing, the Simplex AF was more viscous than Simplex P. No statistical difference existed between the 2 cement groups, for neither translation nor rotation migration data. Subsidence of the stem at 2-year follow-up was 1.1 +/- 0.56 mm for Simplex AF cement and 1.5 +/- 1.00 mm for Simplex P cement. The mean rotation of the acetabular components about the sagittal axis was 1.7 degrees +/- 3.8 degrees in the Simplex AF group and 0.7 degrees +/- 2.1 degrees for the Simplex P group. No effect of cement mantle thickness on migration of neither the acetabular cups nor the femoral stems was found. Although there were no differences in migration data for the cups and the stems, 2 acetabular cups in the Simplex AF group (almost 10%) were revised because of mechanical loosening. Because of these findings, we suggest caution before using this new high-viscosity bone cement for fixation of acetabular components.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16124971     DOI: 10.1016/j.arth.2004.09.036

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  11 in total

1.  Timing of femoral prosthesis insertion during cemented arthroplasty: cement curing and static mechanical strength in an in vivo model.

Authors:  Stephen Hunt; Craig Stone; Shane Seal
Journal:  Can J Surg       Date:  2011-02       Impact factor: 2.089

2.  Bone Cements Used for Hip Prosthesis Fixation: The Influence of the Handling Procedures on Functional Properties Observed during In Vitro Study.

Authors:  Alina Robu; Robert Ciocoiu; Aurora Antoniac; Iulian Antoniac; Anca Daniela Raiciu; Horatiu Dura; Norin Forna; Mihai Bogdan Cristea; Ioana Dana Carstoc
Journal:  Materials (Basel)       Date:  2022-04-19       Impact factor: 3.748

3.  The Exeter femoral stem continues to migrate during its first decade after implantation: 10-12 years of follow-up with radiostereometric analysis (RSA).

Authors:  Marc J Nieuwenhuijse; Edward R Valstar; Bart L Kaptein; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2012-03-08       Impact factor: 3.717

Review 4.  Early subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.

Authors:  Paul van der Voort; Bart G Pijls; Marc J Nieuwenhuijse; Jorrit Jasper; Marta Fiocco; Josepha W M Plevier; Saskia Middeldorp; Edward R Valstar; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2015       Impact factor: 3.717

Review 5.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

6.  Migration and strains induced by different designs of force-closed stems for THA.

Authors:  Sandro Griza; Luiz Sérgio Marcelino Gomes; André Cervieri; Telmo Roberto Strohaecker
Journal:  Rev Bras Ortop       Date:  2015-10-23

7.  A prospective study of hip revision surgery using the Exeter long-stem prosthesis: function, subsidence, and complications for 57 patients.

Authors:  K Randhawa; F S Hossain; B Smith; Cyril Mauffrey; T Lawrence
Journal:  J Orthop Traumatol       Date:  2009-10-24

8.  Fixation of the cemented stem: clinical relevance of the porosity and thickness of the cement mantle.

Authors:  Philippe Hernigou; Gildasio Daltro; Charles Henri Flouzat Lachaniette; Xavier Roussignol; Martin Mukisi Mukasa; Alexandre Poignard
Journal:  Open Orthop J       Date:  2009-02-12

Review 9.  Temporal subsidence patterns of cemented polished taper-slip stems: a systematic review.

Authors:  Kwaku Baryeh; Jeewaka Mendis; David H Sochart
Journal:  EFORT Open Rev       Date:  2021-05-04

Review 10.  Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies.

Authors:  Bart G Pijls; Marc J Nieuwenhuijse; Marta Fiocco; Josepha Wm Plevier; Saskia Middeldorp; Rob Ghh Nelissen; Edward R Valstar
Journal:  Acta Orthop       Date:  2012-11-05       Impact factor: 3.717

View more