BACKGROUND: This study aims to assess the incidence and clinical relevance of slow ventricular tachycardia (VT) and the effectiveness and/or deleterious effects of antitachycardia pacing in slow VT in implantable cardioverter-defibrillator recipients. METHODS AND
RESULTS: This multicenter prospective randomized study included 374 patients (326 men) without prior history of slow VT (<148 bpm) implanted with a dual-chamber implantable cardioverter-defibrillator. Patients had a 3-zone detection configuration: a slow VT zone (101 to 148 bpm), a conventional VT zone (>148 bpm), and a ventricular fibrillation zone. Patients were randomized to a treatment group (n=183) with therapy activated in the slow VT zone or a monitoring group (n=191) with no therapy in the slow VT zone. During follow-up (11 months), 449 slow VTs occurred in 114 patients (30.5% slow VT incidence); 181 VTs (54 patients) occurred in the monitoring group; 3 were readmitted to the hospital; and lightheadedness and palpitations occurred in 4 and 250 (60 patients) in the treatment group treated by antitachycardia pacing (89.8% success rate) and shock delivery (n=2). There were 10 crossovers from the monitoring to treatment group and 3 crossovers from the treatment to monitoring group (P=0.09). Quality of life scores were not different between groups.
CONCLUSIONS: Slow VT incidence (<150 bpm) is high (30%) in implantable cardioverter-defibrillator recipients without prior history of slow VT, has limited clinical relevance, and is efficiently and safely terminated by antitachycardia pacing.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16103252     DOI: 10.1161/CIRCULATIONAHA.105.533513

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  8 in total

1.  [Stored electrograms in pacemakers and ICD systems from the Sorin Group].

Authors:  R U Mletzko; R Ocklenburg; L Prizelius
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2010-03

Review 2.  [Tachycardia detection in implantable cardioverter-defibrillators by Sorin/LivaNova : Algorithms, pearls and pitfalls].

Authors:  Christof Kolb; Rolf Ocklenburg
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-09-07

3.  Electrophysiologic study: its predictive value for ventricular arrhythmias.

Authors:  Daniel R Gold; John N Catanzaro; John N Makaryus; Cory Waldman; William H Sauer; Cristina Sison; Amgad N Makaryus; Erik Altman; Ram Jadonath; Stuart Beldner
Journal:  Tex Heart Inst J       Date:  2010

4.  Spironolactone therapy is associated with reduced ventricular tachycardia rate in patients with cardiomyopathy.

Authors:  Vassilis Dimas; Colby Ayers; James Daniels; Jose A Joglar; Joseph A Hill; R Haris Naseem
Journal:  Pacing Clin Electrophysiol       Date:  2010-10-14       Impact factor: 1.976

5.  Safety and efficacy of high-rate cutoff and long detection interval ICD programming in secondary prevention patients.

Authors:  Yusuke Hayashi; Masahiko Takagi; Jun Kakihara; Shogo Sakamoto; Atsushi Doi; Kenichi Sugioka; Akihisa Hanatani; Minoru Yoshiyama
Journal:  Heart Vessels       Date:  2016-06-03       Impact factor: 2.037

6.  Single-chamber ICD, single-zone therapy in primary and secondary prevention patients: the simpler the better?

Authors:  S González-Enríquez; F Rodríguez-Entem; V Expósito; C Castrillo-Bustamante; A Canteli; A Solloso; I Madrazo; J J Olalla
Journal:  J Interv Card Electrophysiol       Date:  2012-10-19       Impact factor: 1.900

7.  Slow ventricular tachycardia presenting with acute liver failure.

Authors:  Andreas Wannhoff; Christian Nusshag; Wolfgang Stremmel; Uta Merle
Journal:  SAGE Open Med Case Rep       Date:  2017-07-12

8.  A case of pseudo-appropriate shock.

Authors:  Neal J Ferrick; John D Fisher; Jay N Gross; Andrew K Krumerman
Journal:  HeartRhythm Case Rep       Date:  2020-03-13
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.