BACKGROUND: This study aims to assess the incidence and clinical relevance of slow ventricular tachycardia (VT) and the effectiveness and/or deleterious effects of antitachycardia pacing in slow VT in implantable cardioverter-defibrillator recipients. METHODS AND RESULTS: This multicenter prospective randomized study included 374 patients (326 men) without prior history of slow VT (<148 bpm) implanted with adual-chamber implantable cardioverter-defibrillator. Patients had a 3-zone detection configuration: a slow VT zone (101 to 148 bpm), a conventional VT zone (>148 bpm), and a ventricular fibrillation zone. Patients were randomized to a treatment group (n=183) with therapy activated in the slow VT zone or a monitoring group (n=191) with no therapy in the slow VT zone. During follow-up (11 months), 449 slow VTs occurred in 114 patients (30.5% slow VT incidence); 181 VTs (54 patients) occurred in the monitoring group; 3 were readmitted to the hospital; and lightheadedness and palpitations occurred in 4 and 250 (60 patients) in the treatment group treated by antitachycardia pacing (89.8% success rate) and shock delivery (n=2). There were 10 crossovers from the monitoring to treatment group and 3 crossovers from the treatment to monitoring group (P=0.09). Quality of life scores were not different between groups. CONCLUSIONS: Slow VT incidence (<150 bpm) is high (30%) in implantable cardioverter-defibrillator recipients without prior history of slow VT, has limited clinical relevance, and is efficiently and safely terminated by antitachycardia pacing.
RCT Entities:
BACKGROUND: This study aims to assess the incidence and clinical relevance of slow ventricular tachycardia (VT) and the effectiveness and/or deleterious effects of antitachycardia pacing in slow VT in implantable cardioverter-defibrillator recipients. METHODS AND RESULTS: This multicenter prospective randomized study included 374 patients (326 men) without prior history of slow VT (<148 bpm) implanted with a dual-chamber implantable cardioverter-defibrillator. Patients had a 3-zone detection configuration: a slow VT zone (101 to 148 bpm), a conventional VT zone (>148 bpm), and a ventricular fibrillation zone. Patients were randomized to a treatment group (n=183) with therapy activated in the slow VT zone or a monitoring group (n=191) with no therapy in the slow VT zone. During follow-up (11 months), 449 slow VTs occurred in 114 patients (30.5% slow VT incidence); 181 VTs (54 patients) occurred in the monitoring group; 3 were readmitted to the hospital; and lightheadedness and palpitations occurred in 4 and 250 (60 patients) in the treatment group treated by antitachycardia pacing (89.8% success rate) and shock delivery (n=2). There were 10 crossovers from the monitoring to treatment group and 3 crossovers from the treatment to monitoring group (P=0.09). Quality of life scores were not different between groups. CONCLUSIONS: Slow VT incidence (<150 bpm) is high (30%) in implantable cardioverter-defibrillator recipients without prior history of slow VT, has limited clinical relevance, and is efficiently and safely terminated by antitachycardia pacing.
Authors: Daniel R Gold; John N Catanzaro; John N Makaryus; Cory Waldman; William H Sauer; Cristina Sison; Amgad N Makaryus; Erik Altman; Ram Jadonath; Stuart Beldner Journal: Tex Heart Inst J Date: 2010
Authors: Vassilis Dimas; Colby Ayers; James Daniels; Jose A Joglar; Joseph A Hill; R Haris Naseem Journal: Pacing Clin Electrophysiol Date: 2010-10-14 Impact factor: 1.976
Authors: S González-Enríquez; F Rodríguez-Entem; V Expósito; C Castrillo-Bustamante; A Canteli; A Solloso; I Madrazo; J J Olalla Journal: J Interv Card Electrophysiol Date: 2012-10-19 Impact factor: 1.900