Literature DB >> 20548804

Electrophysiologic study: its predictive value for ventricular arrhythmias.

Daniel R Gold1, John N Catanzaro, John N Makaryus, Cory Waldman, William H Sauer, Cristina Sison, Amgad N Makaryus, Erik Altman, Ram Jadonath, Stuart Beldner.   

Abstract

Studies have shown the predictive value of inducible ventricular tachycardia and clinical arrhythmia in patients who have structural heart disease. We examined the possible predictive value of electrophysiologic study before the placement of an implantable cardioverter-defibrillator. Our retrospective study group comprised 315 patients who had ventricular tachycardia that was inducible during electrophysiologic study and who had undergone at least 1 month of follow-up (247 men; mean age, 66.9 +/- 13.5 yr; mean follow-up, 24.9 +/- 14.8 mo). Recorded characteristics included induced ventricular tachycardia cycle length, atrio-His and His-ventricular electrograms, PR and QT intervals, QRS duration, and drug therapy. Of the 315 patients, 97 experienced ventricular arrhythmia during the follow-up period, as registered by 184 of more than 400 interrogations. There were 187 episodes of ventricular arrhythmia (tachycardia, 178; fibrillation, 9) during 652.5 person-years of follow-up. Subjects with a cycle length > or =240 msec were more likely to have an earlier 1st arrhythmia than those with a cycle length <240 msec (P=0.032). A quarter of the subjects with a cycle length > or =240 msec had their 1st arrhythmia by 19.14 months, compared with 23.8 months for a quarter of the subjects with a cycle length <240 msec (P <0.032). Among the electrophysiologic characteristics examined, inducible ventricular tachycardia with a cycle length > or =240 msec is predictive of appropriate implantable cardioverter-defibrillator therapy at an earlier time. This may have prognostic implications that warrant implantable cardioverter-defibrillator programming to enable appropriate antitachycardia pacing in this group of patients.

Entities:  

Keywords:  Arrhythmias, cardiac/prevention & control; death, sudden, cardiac/prevention & control; defibrillators, implantable; electric countershock; electric stimulation; electrophysiologic techniques, cardiac; predictive value of tests; resuscitation; tachycardia, ventricular/therapy; ventricular fibrillation/therapy

Mesh:

Year:  2010        PMID: 20548804      PMCID: PMC2879215     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  25 in total

1.  Effect of first ventricular tachycardia cycle length on rate of ventricular arrhythmia recurrence in patients with implantable cardioverter-defibrillator.

Authors:  Arash Arya; Majid Haghjoo; Mohammad Hosein Nikoo; Mohammad Reza Dehghani; Amir Farjam Fazelifar; Mohammad Ali Sadr-Ameli
Journal:  J Electrocardiol       Date:  2006-03-09       Impact factor: 1.438

2.  A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias.

Authors: 
Journal:  N Engl J Med       Date:  1997-11-27       Impact factor: 91.245

3.  Impact of volume loading and load reduction on ventricular refractoriness and conduction properties in canine congestive heart failure.

Authors:  W X Zhu; S B Johnson; R Brandt; J Burnett; D L Packer
Journal:  J Am Coll Cardiol       Date:  1997-09       Impact factor: 24.094

4.  Repolarization abnormalities, arrhythmia and sudden death in canine tachycardia-induced cardiomyopathy.

Authors:  P H Pak; H B Nuss; R S Tunin; S Kääb; G F Tomaselli; E Marban; D A Kass
Journal:  J Am Coll Cardiol       Date:  1997-08       Impact factor: 24.094

5.  Predictive value of ventricular arrhythmia inducibility for subsequent ventricular tachycardia or ventricular fibrillation in Multicenter Automatic Defibrillator Implantation Trial (MADIT) II patients.

Authors:  James P Daubert; Wojciech Zareba; W Jackson Hall; Claudio Schuger; Andrew Corsello; Angel R Leon; Mark L Andrews; Scott McNitt; David T Huang; Arthur J Moss
Journal:  J Am Coll Cardiol       Date:  2005-12-15       Impact factor: 24.094

6.  Incidence and clinical relevance of slow ventricular tachycardia in implantable cardioverter-defibrillator recipients: an international multicenter prospective study.

Authors:  Nicolas Sadoul; Ralph Mletzko; Frédéric Anselme; Robert Bowes; Wolfgang Schöls; Claude Kouakam; Gaëlle Casteigneau; Raffaele Luise; Nicolas Iscolo; Etienne Aliot
Journal:  Circulation       Date:  2005-08-16       Impact factor: 29.690

7.  Characteristics of calcium-current in isolated human ventricular myocytes from patients with terminal heart failure.

Authors:  D J Beuckelmann; M Näbauer; E Erdmann
Journal:  J Mol Cell Cardiol       Date:  1991-08       Impact factor: 5.000

8.  Electrophysiologic substrate associated with pacing-induced heart failure in dogs: potential value of programmed stimulation in predicting sudden death.

Authors:  H G Li; D L Jones; R Yee; G J Klein
Journal:  J Am Coll Cardiol       Date:  1992-02       Impact factor: 24.094

9.  Intracellular calcium handling in isolated ventricular myocytes from patients with terminal heart failure.

Authors:  D J Beuckelmann; M Näbauer; E Erdmann
Journal:  Circulation       Date:  1992-03       Impact factor: 29.690

10.  Calcium current in single cells isolated from normal and hypertrophied rat heart. Effects of beta-adrenergic stimulation.

Authors:  F Scamps; E Mayoux; D Charlemagne; G Vassort
Journal:  Circ Res       Date:  1990-07       Impact factor: 17.367

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.