Immunoassay interference by a commonly used blood collection tube additive, the organosilicone surfactant silwet L-720.

Raffick A R Bowen1, Yung Chan, Mark E Ruddel, Glen L Hortin, Gyorgy Csako, Stephen J Demosky, Alan T Remaley.   

Abstract

BACKGROUND: A small number of immunoassays on several different types of analyzers were recently adversely affected by tube additives in Becton Dickinson (BD) Vacutainer SST, SST II, and Microtainer blood collection tubes. We examined the effect of a commonly used tube surfactant, Silwet L-720, on immunoassays and the mechanism for the interference.
METHODS: Immunoassays were performed on serum supplemented with Silwet L-720 on the IMMULITE 2500 and AxSYM analyzers. Direct effects of the surfactant on the chemiluminescent detection step of immunoassays and on antibody immobilization on the solid phase were examined.
RESULTS: Increasing the final surfactant concentration from 0 to 400 mg/L in serum significantly increased (approximately 51%) the apparent total triiodothyronine (TT3) concentrations measured on the IMMULITE 2500 but not the AxSYM analyzer. Several other competitive, but not noncompetitive, assays were also significantly affected by the surfactant on the IMMULITE 2500 analyzer. The effect was independent of serum components, and the surfactant had no direct effect on chemiluminescence reactions. The capture antibody, however, was displaced from the solid phase by incubation with solutions containing surfactant under conditions similar to the IMMULITE TT3 assay.
CONCLUSIONS: The Silwet L-720 surfactant, which is used to coat the inner surfaces of tubes, appears to account for previously reported immunoassay interference by BD Vacutainer SST blood collection tubes. One of the mechanisms for the interference is the desorption of antibodies from the solid phase by the surfactant. The results identify an important factor in the selection of suitable blood collection tube surfactants and provide an approach for solving similar tube-assay interference problems in the future.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16099932     DOI: 10.1373/clinchem.2005.055400

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  7 in total

1.  Interference testing.

Authors:  Goce Dimeski
Journal:  Clin Biochem Rev       Date:  2008-08

2.  Blood collection tube-related alterations in analyte concentrations in quality control material and serum specimens.

Authors:  Raffick A R Bowen; Annie Sattayapiwat; Verena Gounden; Alan T Remaley
Journal:  Clin Biochem       Date:  2013-11-14       Impact factor: 3.281

Review 3.  Steroid assays in paediatric endocrinology.

Authors:  John W Honour
Journal:  J Clin Res Pediatr Endocrinol       Date:  2010-02-01

4.  Implementation of biological variation-based analytical performance specifications in the laboratory: Stringent evaluation of Improvacutor blood collection tubes.

Authors:  Hee-Jung Chung; Yoon Kyung Song; Sung Kuk Hong; Sang-Hyun Hwang; Hee Seung Seo; Dong Hee Whang; Myung-Hyun Nam; Do Hoon Lee
Journal:  PLoS One       Date:  2017-12-20       Impact factor: 3.240

5.  A comparative study on the effect of blood collection tubes on stress oxidative markers.

Authors:  Alireza Bastin; Saba Fooladi; Amir Hossein Doustimotlagh; Sina Vakili; Amir Hashem Aminizadeh; Sanaz Faramarz; Hamidreza Shiri; Mohammad Hadi Nematollahi
Journal:  PLoS One       Date:  2022-04-06       Impact factor: 3.240

Review 6.  Interferences from blood collection tube components on clinical chemistry assays.

Authors:  Raffick A R Bowen; Alan T Remaley
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

7.  Stability studies of common biochemical analytes in serum separator tubes with or without gel barrier subjected to various storage conditions.

Authors:  Serap Cuhadar; Ayşenur Atay; Mehmet Koseoglu; Ahmet Dirican; Aysel Hur
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

  7 in total