Literature DB >> 16099687

Impact of electromagnetic field exposure limits in Europe: is the future of interventional MRI safe?

Derek L G Hill1, Kate McLeish, Stephen F Keevil.   

Abstract

The European Union (EU) has recently introduced a directive that aims to protect workers from adverse effects of exposure to electromagnetic fields. All countries within the EU are required to incorporate this directive into their national law by 2008. This legislation applies to all types of occupational exposure to electromagnetic fields with frequencies from 0 Hz to 300 GHz. It has dramatic implications for interventional magnetic resonance (MR) imaging, because workers who are close to the MR scanner while scanning is taking place are exposed at levels substantially above the exposure limits. This is especially the case for time-varying magnetic fields in the 110 Hz-5 kHz range, which includes the field from the imaging gradients. In this article, the scientific evidence on which the limits are based is brought into question. It is concluded that an urgent review of the directive is required and that more research, especially at MR gradient frequencies, is needed.

Mesh:

Year:  2005        PMID: 16099687     DOI: 10.1016/j.acra.2005.05.023

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  5 in total

Review 1.  Occupational exposure in MRI.

Authors:  D W McRobbie
Journal:  Br J Radiol       Date:  2012-04       Impact factor: 3.039

2.  MR safety: simultaneous B0, dΦ/dt, and dB/dt measurements on MR-workers up to 7 T.

Authors:  Jens Groebner; Reiner Umathum; Michael Bock; Axel J Krafft; Wolfhard Semmler; Jaane Rauschenberg
Journal:  MAGMA       Date:  2011-07-14       Impact factor: 2.310

Review 3.  Occupational exposure to electromagnetic fields in magnetic resonance environment: basic aspects and review of exposure assessment approaches.

Authors:  Valentina Hartwig; Stefania Romeo; Olga Zeni
Journal:  Med Biol Eng Comput       Date:  2018-01-18       Impact factor: 2.602

Review 4.  Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research.

Authors:  Simone Rossi; Mark Hallett; Paolo M Rossini; Alvaro Pascual-Leone
Journal:  Clin Neurophysiol       Date:  2009-10-14       Impact factor: 3.708

Review 5.  Safety and recommendations for TMS use in healthy subjects and patient populations, with updates on training, ethical and regulatory issues: Expert Guidelines.

Authors:  Simone Rossi; Andrea Antal; Sven Bestmann; Marom Bikson; Carmen Brewer; Jürgen Brockmöller; Linda L Carpenter; Massimo Cincotta; Robert Chen; Jeff D Daskalakis; Vincenzo Di Lazzaro; Michael D Fox; Mark S George; Donald Gilbert; Vasilios K Kimiskidis; Giacomo Koch; Risto J Ilmoniemi; Jean Pascal Lefaucheur; Letizia Leocani; Sarah H Lisanby; Carlo Miniussi; Frank Padberg; Alvaro Pascual-Leone; Walter Paulus; Angel V Peterchev; Angelo Quartarone; Alexander Rotenberg; John Rothwell; Paolo M Rossini; Emiliano Santarnecchi; Mouhsin M Shafi; Hartwig R Siebner; Yoshikatzu Ugawa; Eric M Wassermann; Abraham Zangen; Ulf Ziemann; Mark Hallett
Journal:  Clin Neurophysiol       Date:  2020-10-24       Impact factor: 4.861

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.