Preservation of residual hearing with cochlear implantation: how and why.

Chris James1, Klaus Albegger, Rolf Battmer, Sandro Burdo, Naima Deggouj, Olivier Deguine, Norbert Dillier, Michel Gersdorff, Roland Laszig, Thomas Lenarz, Manuel Manrique Rodriguez, Michel Mondain, Erwin Offeciers, Angel Ramos Macías, Richard Ramsden, Olivier Sterkers, Ernst Von Wallenberg, Benno Weber, Bernard Fraysse.   

Abstract

CONCLUSIONS: Hearing may be conserved in adults after implantation with the Nucleus Contour Advance perimodiolar electrode array. The degree of hearing preservation and the maximum insertion depth of the electrode array can vary considerably despite a defined surgical protocol. Residual hearing combined with electrical stimulation in the same ear can provide additional benefits even for conventional candidates for cochlear implantation.
OBJECTIVES: We present preliminary results from a prospective multicentre study investigating the conservation of residual hearing after implantation with a standard-length Nucleus Contour Advance perimodiolar electrode array and the benefits of combined electrical and acoustic stimulation.
MATERIAL AND METHODS: The subjects were 12 adult candidates for cochlear implantation recruited according to national selection criteria. A "soft" surgery protocol was defined, as follows: 1-1.2-mm cochleostomy hole anterior and inferior to the round window; Nucleus Contour Advance electrode array inserted using the "Advance-off-stylet" technique; and insertion depth controlled by means of three square marker ribs left outside the cochleostomy hole. These procedures had been shown to reduce insertion forces in temporal bone preparations. Variations in surgical techniques were monitored using a questionnaire. Pure-tone thresholds were measured pre- and postoperatively. Patients who still retained thresholds <90 dB HL for frequencies up to 500 Hz were re-fitted with an in-the-ear (ITE) hearing aid. Word recognition was tested in quiet and sentence perception in noise for the cochlear implant alone and in combination with an ipsilateral hearing aid.
RESULTS: Hearing threshold level data were available for 12 patients recruited from 6 of the centres. Median increases in hearing threshold levels were 23, 27 and 33 dB for the frequencies 125, 250 and 500 Hz, respectively. These median increases include the data for two patients who had total loss of residual hearing due to difficulties encountered during surgery. "Cochlear view" X-ray images indicated that the depth of insertion varied between 300 and 430 degrees, despite modest variations in the length of the electrode inserted (17-19 mm). The insertion angle had some influence on the preservation of residual hearing at frequencies of 250-500 Hz. Six of the 12 patients retained sufficient hearing for effective use of an ipsilateral ITE hearing aid (< or = 80 dB HL at 125 and 250 Hz; < or = 90 dB HL at 500 Hz). Word recognition scores in quiet were improved from 10% to 30% with the cochlear implant plus ipsilateral hearing aid in 3 patients who had at least 3 months postoperative experience. Signal:noise ratio thresholds for sentence recognition were improved by up to 3 dB. Patients reported that they experienced greatly improved sound quality and preferred to use the two devices together.

Entities:  

Mesh:

Year:  2005        PMID: 16092537     DOI: 10.1080/00016480510026197

Source DB:  PubMed          Journal:  Acta Otolaryngol        ISSN: 0001-6489            Impact factor:   1.494


  69 in total

1.  Impact of the surgical experience on cochleostomy location: a comparative temporal bone study between endaural and posterior tympanotomy approaches for cochlear implantation.

Authors:  Clair Vandersteen; Thomas Demarcy; Coralie Roger; Eric Fontas; Charles Raffaelli; Nicholas Ayache; Hervé Delingette; Nicolas Guevara
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-10-16       Impact factor: 2.503

Review 2.  The development of the Nucleus Freedom Cochlear implant system.

Authors:  James F Patrick; Peter A Busby; Peter J Gibson
Journal:  Trends Amplif       Date:  2006-12

3.  Residual hearing in cochlear implant patients.

Authors:  Walter Di Nardo; Italo Cantore; Pietro Melillo; Francesca Cianfrone; Alessandro Scorpecci; Gaetano Paludetti
Journal:  Eur Arch Otorhinolaryngol       Date:  2007-02-27       Impact factor: 2.503

4.  Anatomy of the round window and hook region of the cochlea with implications for cochlear implantation and other endocochlear surgical procedures.

Authors:  Peter M M C Li; Haobing Wang; Clarinda Northrop; Saumil N Merchant; Joseph B Nadol
Journal:  Otol Neurotol       Date:  2007-08       Impact factor: 2.311

Review 5.  Combined acoustic and electric hearing: preserving residual acoustic hearing.

Authors:  Christopher W Turner; Lina A J Reiss; Bruce J Gantz
Journal:  Hear Res       Date:  2007-11-29       Impact factor: 3.208

Review 6.  Soft cochlear implantation: rationale for the surgical approach.

Authors:  David R Friedland; Christina Runge-Samuelson
Journal:  Trends Amplif       Date:  2009-06

7.  A Preliminary Investigation of the Air-Bone Gap: Changes in Intracochlear Sound Pressure With Air- and Bone-conducted Stimuli After Cochlear Implantation.

Authors:  Renee M Banakis Hartl; Jameson K Mattingly; Nathaniel T Greene; Herman A Jenkins; Stephen P Cass; Daniel J Tollin
Journal:  Otol Neurotol       Date:  2016-10       Impact factor: 2.311

8.  Role of electrode placement as a contributor to variability in cochlear implant outcomes.

Authors:  Charles C Finley; Timothy A Holden; Laura K Holden; Bruce R Whiting; Richard A Chole; Gail J Neely; Timothy E Hullar; Margaret W Skinner
Journal:  Otol Neurotol       Date:  2008-10       Impact factor: 2.311

Review 9.  The Hybrid cochlear implant: a review.

Authors:  Erika A Woodson; Lina A J Reiss; Christopher W Turner; Kate Gfeller; Bruce J Gantz
Journal:  Adv Otorhinolaryngol       Date:  2009-11-25

Review 10.  Frequency-lowering devices for managing high-frequency hearing loss: a review.

Authors:  Andrea Simpson
Journal:  Trends Amplif       Date:  2009-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.