Abstract

We present a new approach for performing fluorescence immunoassay in whole blood using fluorescently labeled anti-rabbit immunoglobulin G (IgG) on a silver surface. This approach, which is based on surface plasmon-coupled emission (SPCE), provides increased sensitivity and substantial background reduction due to exclusive selection of the signal from the fluorophores located near a bioaffinity surface. This article describes the effect of an optically dense sample matrix, namely human whole blood and serum, on the intensity of the SPCE. An antigen (rabbit IgG) was adsorbed to a slide covered with a thin silver metal layer, and the SPCE signal from the fluorophore-labeled anti-rabbit antibody, binding to the immobilized antigen, was detected. The effect of the sample matrix (buffer, human serum, or human whole blood) on the end-point immunoassay SPCE signal was studied. It was demonstrated that the kinetics of binding could be monitored directly in whole blood or serum. The results showed that human serum and human whole blood attenuate the SPCE end-point signal and the immunoassay kinetic signal only approximately two- and threefold, respectively, as compared with buffer, resulting in signals that are easily detectable even in whole blood. The high optical absorption of the hemoglobin can be tolerated because only fluorophores within a couple of hundred nanometers from the metallic film contribute to SPCE. Excited fluorophores outside the 200-nm layer do not contribute to SPCE, and their free space emission is not transmitted through the opaque metallic film into the glass substrate. We believe that SPCE has the potential of becoming a powerful approach for performing immunoassays based on surface-bound analytes or antibodies for many biomarkers directly in dense samples such as whole blood with no need for washing steps.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16091280      PMCID: PMC6816263          DOI: 10.1016/j.ab.2005.07.005

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  24 in total

1.  Two-photon fluorescence excitation in detection of biomolecules.

Authors:  E Soini; N J Meltola; A E Soini; J Soukka; J T Soini; P E Hänninen
Journal:  Biochem Soc Trans       Date:  2000-02       Impact factor: 5.407

Review 2.  Antibodies in diagnostics - from immunoassays to protein chips.

Authors:  C A Borrebaeck
Journal:  Immunol Today       Date:  2000-08

Review 3.  Immunosensors--principles and applications to clinical chemistry.

Authors:  P B Luppa; L J Sokoll; D W Chan
Journal:  Clin Chim Acta       Date:  2001-12       Impact factor: 3.786

4.  A europium chelate for quantitative point-of-care immunoassays using direct surface measurement.

Authors:  Piia von Lode; Jaana Rosenberg; Kim Pettersson; Harri Takalo
Journal:  Anal Chem       Date:  2003-07-01       Impact factor: 6.986

Review 5.  Antibodies in diagnostic applications.

Authors:  Sergey Y Tetin; Stephen D Stroupe
Journal:  Curr Pharm Biotechnol       Date:  2004-02       Impact factor: 2.837

6.  Development and validation of a nonaplex assay for the simultaneous quantitation of antibodies to nine Streptococcus pneumoniae serotypes.

Authors:  Gouri Lal; Paul Balmer; Elaine Stanford; Sarah Martin; Rosalind Warrington; Ray Borrow
Journal:  J Immunol Methods       Date:  2004-12-08       Impact factor: 2.303

7.  Myoglobin immunoassay utilizing directional surface plasmon-coupled emission.

Authors:  Evgenia Matveeva; Zygmunt Gryczynski; Ignacy Gryczynski; Joanna Malicka; Joseph R Lakowicz
Journal:  Anal Chem       Date:  2004-11-01       Impact factor: 6.986

8.  Measurement of bovine IgG by indirect competitive ELISA as a means of detecting milk adulteration.

Authors:  I P Hurley; R C Coleman; H E Ireland; J H H Williams
Journal:  J Dairy Sci       Date:  2004-03       Impact factor: 4.034

9.  Comparison of a multiplexed fluorescent covalent microsphere immunoassay and an enzyme-linked immunosorbent assay for measurement of human immunoglobulin G antibodies to anthrax toxins.

Authors:  Raymond E Biagini; Deborah L Sammons; Jerome P Smith; Barbara A MacKenzie; Cynthia A F Striley; Vera Semenova; Evelen Steward-Clark; Karen Stamey; Alison E Freeman; Conrad P Quinn; John E Snawder
Journal:  Clin Diagn Lab Immunol       Date:  2004-01

10.  Radiative decay engineering 4. Experimental studies of surface plasmon-coupled directional emission.

Authors:  Ignacy Gryczynski; Joanna Malicka; Zygmunt Gryczynski; Joseph R Lakowicz
Journal:  Anal Biochem       Date:  2004-01-15       Impact factor: 3.365

View more
  6 in total

1.  Plastic versus glass support for an immunoassay on metal-coated surfaces in optically dense samples utilizing directional surface plasmon-coupled emission.

Authors:  Evgenia G Matveeva; Ignacy Gryczynski; Joanna Malicka; Zygmunt Gryczynski; Ewa Goldys; Joseph Howe; Klaus W Berndt; Joseph R Lakowicz
Journal:  J Fluoresc       Date:  2005-11       Impact factor: 2.217

Review 2.  Plasmonic technology: novel approach to ultrasensitive immunoassays.

Authors:  Joseph R Lakowicz; Joanna Malicka; Evgenia Matveeva; Ignacy Gryczynski; Zygmunt Gryczynski
Journal:  Clin Chem       Date:  2005-07-28       Impact factor: 8.327

3.  Whole blood optical biosensor.

Authors:  Lisa M Bonanno; Lisa A DeLouise
Journal:  Biosens Bioelectron       Date:  2007-07-20       Impact factor: 10.618

Review 4.  Plasmon-controlled fluorescence: a new paradigm in fluorescence spectroscopy.

Authors:  Joseph R Lakowicz; Krishanu Ray; Mustafa Chowdhury; Henryk Szmacinski; Yi Fu; Jian Zhang; Kazimierz Nowaczyk
Journal:  Analyst       Date:  2008-07-16       Impact factor: 4.616

5.  Single molecule studies of multiple-fluorophore labeled antibodies. Effect of homo-FRET on the number of photons available before photobleaching.

Authors:  Rafal Luchowski; Evgenia G Matveeva; Ignacy Gryczynski; Ewald A Terpetschnig; Leonid Patsenker; Gabor Laczko; Julian Borejdo; Zygmunt Gryczynski
Journal:  Curr Pharm Biotechnol       Date:  2008-10       Impact factor: 2.837

Review 6.  Plasmon-controlled fluorescence towards high-sensitivity optical sensing.

Authors:  K Ray; M H Chowdhury; J Zhang; Y Fu; H Szmacinski; K Nowaczyk; J R Lakowicz
Journal:  Adv Biochem Eng Biotechnol       Date:  2009       Impact factor: 2.635

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.