Literature DB >> 15680158

Development and validation of a nonaplex assay for the simultaneous quantitation of antibodies to nine Streptococcus pneumoniae serotypes.

Gouri Lal1, Paul Balmer, Elaine Stanford, Sarah Martin, Rosalind Warrington, Ray Borrow.   

Abstract

Serum IgG levels specific for Streptococcus pneumoniae are currently quantified using the ELISA. However, this method has significant limitations in that a separate test is required for each serotype-specific antibody. Here, we describe a rapid and simple method for the simultaneous quantitation of IgG to nine pneumococcal serotypes (1, 4, 5, 6B, 9V, 14, 18C, 19F, 23F). Pneumococcal polysaccharides were covalently attached to fluorescent microspheres and these beads were serologically assessed using 89-SF standard serum. The multiplex assay was linear over a 24-fold serum dilution range and comparison of monoplex and nonaplex assays revealed no evidence of bead interference. The nonaplex assay was shown to be specific with <30% heterologous inhibition occurring and assay sensitivity was high with the LOD ranging between 32.3 and 109.7 pg/ml. The assay was shown to have low inter- and intra-assay variability and conjugated microspheres were shown to remain stable over 12 months. When samples were assayed there was a good correlation of the nonaplex assay with the ELISA. Finally, four bead sets coated with meningococcal polysaccharides (serogroups A, C, Y and W135) were added into the nonaplex assay, with no effect on the pneumococcal or meningococcal IgG levels generated. The pneumococcal nonaplex assay will prove to be a valuable tool to aid in the evaluation of pneumococcal capsular polysaccharide-based vaccines.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15680158     DOI: 10.1016/j.jim.2004.11.006

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  53 in total

1.  Development of a bead-based multiplex immunoassay for simultaneous quantitative detection of IgG serum antibodies against measles, mumps, rubella, and varicella-zoster virus.

Authors:  Gaby P Smits; Pieter G van Gageldonk; Leo M Schouls; Fiona R M van der Klis; Guy A M Berbers
Journal:  Clin Vaccine Immunol       Date:  2012-01-11

2.  Interlaboratory comparison of three multiplexed bead-based immunoassays for measuring serum antibodies to pneumococcal polysaccharides.

Authors:  Melissa J Whaley; Charles Rose; Joseph Martinez; Gouri Laher; Deborah L Sammons; Jerry P Smith; John E Snawder; Ray Borrow; Raymond E Biagini; Brian Plikaytis; George M Carlone; Sandra Romero-Steiner
Journal:  Clin Vaccine Immunol       Date:  2010-03-24

3.  Directional surface plasmon-coupled emission: application for an immunoassay in whole blood.

Authors:  Evgenia G Matveeva; Zygmunt Gryczynski; Joanna Malicka; Joanna Lukomska; Slawomir Makowiec; Klaus W Berndt; Joseph R Lakowicz; Ignacy Gryczynski
Journal:  Anal Biochem       Date:  2005-09-15       Impact factor: 3.365

Review 4.  Anti-pneumococcal antibody titre measurement: what useful information does it yield?

Authors:  Paul Balmer; Andrew J Cant; Ray Borrow
Journal:  J Clin Pathol       Date:  2006-09-01       Impact factor: 3.411

5.  Multiplex assay for simultaneous measurement of antibodies to multiple Plasmodium falciparum antigens.

Authors:  Genevieve G Fouda; Rose F G Leke; Carole Long; Pierre Druilhe; Ainong Zhou; Diane Wallace Taylor; Armead H Johnson
Journal:  Clin Vaccine Immunol       Date:  2006-10-11

6.  Parasitic Infections in Pregnancy Decrease Placental Transfer of Antipneumococcus Antibodies.

Authors:  Noah D McKittrick; David M Vu; Indu Malhotra; Charles H King; Francis Mutuku; A Desiree LaBeaud
Journal:  Clin Vaccine Immunol       Date:  2017-06-05

7.  Comparison of a new multiplex binding assay versus the enzyme-linked immunosorbent assay for measurement of serotype-specific pneumococcal capsular polysaccharide IgG.

Authors:  David Goldblatt; Lindsey Ashton; Yuhua Zhang; Joseph Antonello; Rocio D Marchese
Journal:  Clin Vaccine Immunol       Date:  2011-08-03

8.  Development of a fluorescent-bead-based multiplex immunoassay to determine immunoglobulin G subclass responses to Neisseria meningitidis serogroup A and C polysaccharides.

Authors:  Richarda M de Voer; Fiona R M van der Klis; Carla W A M Engels; Ger T Rijkers; Elisabeth A Sanders; Guy A M Berbers
Journal:  Clin Vaccine Immunol       Date:  2008-06-11

9.  Failure of antibody response to polysaccharide antigen in treated panhypopituitary adults.

Authors:  A Mukherjee; M Helbert; W D J Ryder; R Borrow; J R E Davis; S M Shalet
Journal:  Clin Exp Immunol       Date:  2009-02-10       Impact factor: 4.330

10.  Natural human antibodies to pneumococcus have distinctive molecular characteristics and protect against pneumococcal disease.

Authors:  H E Baxendale; M Johnson; R C M Stephens; J Yuste; N Klein; J S Brown; D Goldblatt
Journal:  Clin Exp Immunol       Date:  2007-11-05       Impact factor: 4.330

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.