Literature DB >> 14715544

Comparison of a multiplexed fluorescent covalent microsphere immunoassay and an enzyme-linked immunosorbent assay for measurement of human immunoglobulin G antibodies to anthrax toxins.

Raymond E Biagini1, Deborah L Sammons, Jerome P Smith, Barbara A MacKenzie, Cynthia A F Striley, Vera Semenova, Evelen Steward-Clark, Karen Stamey, Alison E Freeman, Conrad P Quinn, John E Snawder.   

Abstract

Recently, the Centers for Disease Control and Prevention reported an accurate, sensitive, specific, reproducible, and quantitative enzyme-linked immunosorbent assay (ELISA) for immunoglobulin G (IgG) antibodies to Bacillus anthracis protective antigen (PA) in human serum (C. P. Quinn, V. A. Semenova, C. M. Elie et al., Emerg. Infect. Dis. 8:1103-1110, 2002). The ELISA had a minimum detectable concentration (MDC) of 0.06 microgram/ml, which, when dilution adjusted, yielded a whole-serum MDC of 3.0 micro g of anti-PA IgG per ml. The reliable detection limit (RDL) was 0.09 microgram/ml, while the dynamic range was 0.06 to 1.7 microgram/ml. The diagnostic sensitivity of the assay was 97.6% and the diagnostic specificity was 94.2% for clinically verified cases of anthrax. A competitive inhibition anti-PA IgG ELISA was also developed to enhance the diagnostic specificity to 100%. We report a newly developed fluorescence covalent microbead immunosorbent assay (FCMIA) for B. anthracis PA which was Luminex xMap technology. The FCMIA MDC was 0.006 microgram of anti-PA IgG per ml, the RDL was 0.016 microgram/ml, and the whole-serum equivalent MDC was 1.5 micrograms/ml. The dynamic range was 0.006 to 6.8 microgram/ml. Using this system, we analyzed 20 serum samples for anti-PA IgG and compared our results to those measured by ELISA in a double-masked analysis. The two methods had a high positive correlation (r2 = 0.852; P < 0.001). The FCMIA appears to have benefits over the ELISA for the measurement of anti-PA IgG, including greater sensitivity and speed, enhanced dynamic range and reagent stability, the use of smaller sample volumes, and the ability to be multiplexed (measurement of more than one analyte simultaneously), as evidenced by the multiplexed measurement in the present report of anti-PA and anti-lethal factor IgG in serum from a confirmed clinical anthrax infection.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14715544      PMCID: PMC321348          DOI: 10.1128/cdli.11.1.50-55.2004

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  16 in total

Review 1.  Multiplexed particle-based flow cytometric assays.

Authors:  D A Vignali
Journal:  J Immunol Methods       Date:  2000-09-21       Impact factor: 2.303

2.  Development of multiplexed fluorescence microbead covalent assays (FMCAs) for pesticide biomonitoring.

Authors:  R E Biagini; D M Murphy; D L Sammons; J P Smith; C A F Striley; B A MacKenzie
Journal:  Bull Environ Contam Toxicol       Date:  2002-04       Impact factor: 2.151

3.  Purification and characterization of adenylyl cyclase from Bacillus anthracis.

Authors:  S H Leppla
Journal:  Methods Enzymol       Date:  1991       Impact factor: 1.600

4.  Optimized production and purification of Bacillus anthracis lethal factor.

Authors:  S Park; S H Leppla
Journal:  Protein Expr Purif       Date:  2000-04       Impact factor: 1.650

5.  Analysis of adverse events after anthrax immunization in US Army medical personnel.

Authors:  Glenn M Wasserman; John D Grabenstein; Phillip R Pittman; Mark V Rubertone; Paul P Gibbs; Linda Z Wang; Lance G Golder
Journal:  J Occup Environ Med       Date:  2003-03       Impact factor: 2.162

6.  A multiplexed fluorescent microsphere immunoassay for antibodies to pneumococcal capsular polysaccharides.

Authors:  Jerry W Pickering; Thomas B Martins; Ryan W Greer; M Carl Schroder; Mark E Astill; Christine M Litwin; Stephen W Hildreth; Harry R Hill
Journal:  Am J Clin Pathol       Date:  2002-04       Impact factor: 2.493

Review 7.  Validation of serological assays for diagnosis of infectious diseases.

Authors:  R H Jacobson
Journal:  Rev Sci Tech       Date:  1998-08       Impact factor: 1.181

8.  Comparisons of standard curve-fitting methods to quantitate Neisseria meningitidis group A polysaccharide antibody levels by enzyme-linked immunosorbent assay.

Authors:  B D Plikaytis; S H Turner; L L Gheesling; G M Carlone
Journal:  J Clin Microbiol       Date:  1991-07       Impact factor: 5.948

9.  Simultaneous detection of 15 human cytokines in a single sample of stimulated peripheral blood mononuclear cells.

Authors:  Wilco de Jager; Henk te Velthuis; Berent J Prakken; Wietse Kuis; Ger T Rijkers
Journal:  Clin Diagn Lab Immunol       Date:  2003-01

10.  Specific, sensitive, and quantitative enzyme-linked immunosorbent assay for human immunoglobulin G antibodies to anthrax toxin protective antigen.

Authors:  Conrad P Quinn; Vera A Semenova; Cheryl M Elie; Sandra Romero-Steiner; Carolyn Greene; Han Li; Karen Stamey; Evelene Steward-Clark; Daniel S Schmidt; Elizabeth Mothershed; Janet Pruckler; Stephanie Schwartz; Robert F Benson; Leta O Helsel; Patricia F Holder; Scott E Johnson; Molly Kellum; Trudy Messmer; W Lanier Thacker; Lilah Besser; Brian D Plikaytis; Thomas H Taylor; Alison E Freeman; Kelly J Wallace; Peter Dull; Jim Sejvar; Erica Bruce; Rosa Moreno; Anne Schuchat; Jairam R Lingappa; Sandra K Martin; John Walls; Melinda Bronsdon; George M Carlone; Mary Bajani-Ari; David A Ashford; David S Stephens; Bradley A Perkins
Journal:  Emerg Infect Dis       Date:  2002-10       Impact factor: 6.883

View more
  27 in total

1.  Formation of droplets of alternating composition in microfluidic channels and applications to indexing of concentrations in droplet-based assays.

Authors:  Bo Zheng; Joshua D Tice; Rustem F Ismagilov
Journal:  Anal Chem       Date:  2004-09-01       Impact factor: 6.986

2.  A Liquid-Handling Robot for Automated Attachment of Biomolecules to Microbeads.

Authors:  Aaron Enten; Yujia Yang; Zihan Ye; Ryan Chu; Tam Van; Ben Rothschild; Francisco Gonzalez; Todd Sulchek
Journal:  J Lab Autom       Date:  2015-08-26

Review 3.  Current and developing technologies for monitoring agents of bioterrorism and biowarfare.

Authors:  Daniel V Lim; Joyce M Simpson; Elizabeth A Kearns; Marianne F Kramer
Journal:  Clin Microbiol Rev       Date:  2005-10       Impact factor: 26.132

4.  Validation and comparison of luminex multiplex cytokine analysis kits with ELISA: determinations of a panel of nine cytokines in clinical sample culture supernatants.

Authors:  Nefertiti C dupont; Kehui Wang; Pathik D Wadhwa; Jennifer F Culhane; Edward L Nelson
Journal:  J Reprod Immunol       Date:  2005-08       Impact factor: 4.054

5.  Directional surface plasmon-coupled emission: application for an immunoassay in whole blood.

Authors:  Evgenia G Matveeva; Zygmunt Gryczynski; Joanna Malicka; Joanna Lukomska; Slawomir Makowiec; Klaus W Berndt; Joseph R Lakowicz; Ignacy Gryczynski
Journal:  Anal Biochem       Date:  2005-09-15       Impact factor: 3.365

6.  Multiplex assay for simultaneous measurement of antibodies to multiple Plasmodium falciparum antigens.

Authors:  Genevieve G Fouda; Rose F G Leke; Carole Long; Pierre Druilhe; Ainong Zhou; Diane Wallace Taylor; Armead H Johnson
Journal:  Clin Vaccine Immunol       Date:  2006-10-11

7.  Evaluation of a tetraplex microsphere assay for Bordetella pertussis antibodies.

Authors:  Harry E Prince; Mary Lapé-Nixon; Jose Matud
Journal:  Clin Vaccine Immunol       Date:  2006-02

8.  Racial differences in cervical cytokine concentrations between pregnant women with and without bacterial vaginosis.

Authors:  Kelli K Ryckman; Scott M Williams; Marijane A Krohn; Hyagriv N Simhan
Journal:  J Reprod Immunol       Date:  2008-03-11       Impact factor: 4.054

9.  Rapid, sensitive, and specific lateral-flow immunochromatographic device to measure anti-anthrax protective antigen immunoglobulin g in serum and whole blood.

Authors:  Raymond E Biagini; Deborah L Sammons; Jerome P Smith; Barbara A MacKenzie; Cynthia A F Striley; John E Snawder; Shirley A Robertson; Conrad P Quinn
Journal:  Clin Vaccine Immunol       Date:  2006-05

10.  Naturally-acquired humoral immune responses against the N- and C-termini of the Plasmodium vivax MSP1 protein in endemic regions of Brazil and Papua New Guinea using a multiplex assay.

Authors:  Carmen Fernandez-Becerra; Sergi Sanz; Marina Brucet; Danielle I Stanisic; Fabiana P Alves; Erney P Camargo; Pedro L Alonso; Ivo Mueller; Hernando A del Portillo
Journal:  Malar J       Date:  2010-01-21       Impact factor: 2.979

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.